• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Safety Management System
Safety Management System

TSC50 - 5.7” LCD Color Touchscreen Installation Guide
TSC50 - 5.7” LCD Color Touchscreen Installation Guide

... The LCD Color Touchscreen is a flexible device which provides an intuitive “user friendly” method of including menu driven control functions of the iLumin control system. The LCD Touchscreen provides flexibility of system control to allow end users to decide what they want to see and how they see it ...
a-isometer® ir420 - Bender Benelux BV
a-isometer® ir420 - Bender Benelux BV

... AC control circuits (IT systems) 0…300 V. If the systems to be monitored include DC components, such as switched-mode power supplies or solenoid valves, the display and operating characteristics may be affected. ...
GVR Brochure- Feb 05.indd
GVR Brochure- Feb 05.indd

safety
safety

... A. It affects the average exposure of people to radiation B. It affects the peak exposure of people to ...
ps3-presentation
ps3-presentation

... for current diff. Cross differential relay proposed option for double circuit lines. Examples of new relay principles being researched – surge impedance, noise generated protection and boundary protection techniques Importance of dynamic tests and international research and development collaboration ...
APPLICATION NOTE PolySwitch Strap Devices Help Protect Rechargeable Battery Packs
APPLICATION NOTE PolySwitch Strap Devices Help Protect Rechargeable Battery Packs

... including illustrations, is believed to be accurate and reliable. However, users should independently evaluate the suitability of each product for their application. Tyco Electronics Corporation and/or its Affiliates in the TE Connectivity Ltd. family of companies (“TE”) makes no warranties as to th ...
Ohm`s Law - Schuylkill Technology Center
Ohm`s Law - Schuylkill Technology Center

Camera Lab 4 - 1 - Gateway Engineering Education Coalition
Camera Lab 4 - 1 - Gateway Engineering Education Coalition

...  With a 1.5 volt battery, it takes several seconds to build up the charge  Capacitor discharges quickly (in milliseconds) when a circuit is created between the 2 plates ...
Ohm`s Law - Goodheart
Ohm`s Law - Goodheart

PEO-Underpinning-Knowledge-Questions-Power
PEO-Underpinning-Knowledge-Questions-Power

Point out the Limitations and difficulties of HVDC Transmission System
Point out the Limitations and difficulties of HVDC Transmission System

Development of 22-kV Distribution Systems and Switchgear
Development of 22-kV Distribution Systems and Switchgear

VNI4140K
VNI4140K

... The VNI4140K is compliant with IEC 61131-2 (programmable logic controller international standard); nevertheless it can also be used as a smart-power solid-state relay in any other application with 36 V maximum operating voltage. ...
DC Measurements, Voltage Dividers, and Bridges
DC Measurements, Voltage Dividers, and Bridges

... arm, which is usually used at DC or low frequencies. It has many applications in measurement circuits, where often the unknown resistance Rx is a resistive sensor, such as a platinum thermometer or a mechanical strain gauge (for more info see H&H 15.03). There are other types of bridges, including A ...
PowerFlex 4 Sample Specification GENERAL
PowerFlex 4 Sample Specification GENERAL

Self Switching Power Supply
Self Switching Power Supply

Principles of Electrical Grounding
Principles of Electrical Grounding

... Circuit breakers and fuses, even though sized properly do not always protect. Grounding shields can cause major problems. Most of the time ground only one end, but not always. Some circuits require both ends grounded. New construction methods and materials are causing real problems - elimination of ...
Order Specifications for Off-Circuit Tap Changer Shanghai Huaming
Order Specifications for Off-Circuit Tap Changer Shanghai Huaming

... Note: CMA7 motor drive unit is specified by Huaming for big current WSL/WDL Motor driving at top of OCTC Cable between OCTC & controller ( )m (standard offer 30m ) Only for maximum current 600A, highest voltage 40.5kV, linear regulation and single bridging ...
BU7962GUW
BU7962GUW

... other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipmen ...
Discovering Electricity Discussion Questions
Discovering Electricity Discussion Questions

... believed that direct current was the best method for electicity distribution. George Westinghouse’s company believed that alternating current was best. Eventually alternating current became the preferred method of supply. Scientists knew that high voltage electricity could travel a greater distance ...
Single Converter Provides Positive and Negative Supplies
Single Converter Provides Positive and Negative Supplies

... The LT3472 dual DC/DC converter simplifies the design of dual, positive and negative, supplies by combining two switchers that have independent control loops and ±34V output ranges. Figure 1 shows a circuit using the LT3472 that produces two independently regulated power supplies from a single Lithiu ...
Theory of Breaker Point-Triggered, Transistorized Ignition Systems
Theory of Breaker Point-Triggered, Transistorized Ignition Systems

a AN-397 APPLICATION NOTE •
a AN-397 APPLICATION NOTE •

... space systems, industrial equipment or consumer products. All types of electronic components can be destroyed or degraded. 1 Even capacitors, relays, connectors, printed circuit boards, etc., are susceptible, although their threshold levels are much higher than integrated circuits. Microwave diodes ...
Doubly-Fed Induction Generator Wind Turbine Model for Fault Ride-Through Investigation Yutana Chongjarearn
Doubly-Fed Induction Generator Wind Turbine Model for Fault Ride-Through Investigation Yutana Chongjarearn

... Two three-phase, voltage source converters are employed in the scheme: a rotor side converter (RSC) and a grid side converter (GSC) connected back-toback in a dc link arrangement and controlled using vector control methods [1-3]. In this paper, a statorvoltage-oriented, vector control DFIG model cap ...
< 1 ... 223 224 225 226 227 228 229 230 231 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.