• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Interruption Technology of Breakers for High
Interruption Technology of Breakers for High

End Fed Half Wave Antenna
End Fed Half Wave Antenna

... •Note: a lossy ground will reduce the current flow => smaller RF Field ...
06 Lecture #1 - Clarkson University
06 Lecture #1 - Clarkson University

... – 3.6 Long pants must be worn when soldering, using high voltage equipment, or using machine tools. They are recommended for all other activities in the laboratory ...
03046
03046

... Three-Wire Ungrounded Systems: Description: In a three-wire ungrounded system, no neutral wire is run with the three-phase conductors nor is the transformer grounded at the substation. This means that three-phase system voltages are completely floating with respect to the earth ground. Ground fault ...
Technical Series, Edition 1
Technical Series, Edition 1

Electrostatic Discharges
Electrostatic Discharges

MI 3290 Earth Analyser Earth testers
MI 3290 Earth Analyser Earth testers

doc00000 - Finite Element Method Magnetics
doc00000 - Finite Element Method Magnetics

Transformer Excitation Current Test
Transformer Excitation Current Test

Need miniature circuit breakers that meet world
Need miniature circuit breakers that meet world

... The Multi 9 family provides OEMs with a single family of products to use in their equipment, whether it is destined for the domestic market or for markets outside the United States. Many Multi 9 devices are tested per Underwriters Laboratories (UL) standards to ultimately meet the requirements of th ...
LT Circuit Breaker - 123SeminarsOnly.com
LT Circuit Breaker - 123SeminarsOnly.com

KB006
KB006

... machinery and transformers. During steady state operation of an AC power system, harmonics in the transformer magnetizing current are a small percentage of the load current. Energizing a transformer results in substantial amounts of harmonic current in the transformer inrush current. This is a trans ...
Electrical Safety - HCC Learning Web
Electrical Safety - HCC Learning Web

... • The larger the current flow, the stronger the magnetic field grows and the greater the needle movement on the scale. • The ammeter measures current flow in an electric circuit. • There are two types of ammeters used in the industry today: the clamp-on ammeter and the in-line ammeter. • The clamp-o ...
ﺟﺎﻣﻌﺔ ﺑﻧﮭﺎ ﮐﻟﯾﺔ اﻟﮭﻧدﺳﺔ ﺑﺑﻧﮭﺎ ﻗﺳم اﻟﮭﻧدﺳﺔ اﻟﮐﮭرﺑﯾ
ﺟﺎﻣﻌﺔ ﺑﻧﮭﺎ ﮐﻟﯾﺔ اﻟﮭﻧدﺳﺔ ﺑﺑﻧﮭﺎ ﻗﺳم اﻟﮭﻧدﺳﺔ اﻟﮐﮭرﺑﯾ

... A GTO can operate safely in the “reverse avalanche” region for a short time provided the gate .cathode junction is reverse biased The switching delay times and energy loss of a GTO can be reduced by increasing the gate • .current magnitude and its rate of rise The maximum turn off anode current ...
Experiment FT2: Measurement of Inductance and Mutual Inductance
Experiment FT2: Measurement of Inductance and Mutual Inductance

... If the secondary circuit is closed, for example, by connecting a resistor to the terminals, a current I2 will start to flow. By this electromagnetic induction, the electrical energy is transferred from the primary winding to the secondary winding by means of magnetic field coupling. Assuming that th ...
Resource 1
Resource 1

Fault Finding in Thyristor Equipment
Fault Finding in Thyristor Equipment

... conditions which may be difficult to reproduce. This chapter should help in the location of most faults and does explain the methods which can produce the quickest results. However, there will always be faults which are very difficult to find and no amount of written information will overcome this. ...
human circuit game - Tech Will Save Us
human circuit game - Tech Will Save Us

... gives us resistance, by slowing down the flow of charge and changing it into light. The current flows through the battery, the light bulb and the wires. ...
SP 300-BLUE - Lascar Electronics
SP 300-BLUE - Lascar Electronics

... 3½ Digit LED Voltmeter Module ...
View Activity Guide Preview
View Activity Guide Preview

Three - Phase Electric Power Distribution
Three - Phase Electric Power Distribution

... circuit. It is not necessary for a three-phase circuit to have a neutral wire. The purpose of a neutral wire allows single phase devices to be used from a three-phase circuit. For a high voltage transmission this neutral wire is not commonly present and high voltage loads are connected across the ho ...
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.2, pp. 1765-1770
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.2, pp. 1765-1770

... algorithm. Directional overcurrent functionality has been trained for specific measurement points. The overcurrent block detects an overcurrent and provides instantaneously an active signal when a threshold value is surpassed. The directional block detects whether the direction of the force that bel ...
Basic non-inverting operational amplifier circuit with
Basic non-inverting operational amplifier circuit with

... • This can be achieved by inserting a high value resistor, R3 in the diagram, to ground as shown below. • The value of this may typically be 100 k ohms or more. If this resistor is not inserted the output of the operational amplifier will be driven into one of the voltage rails. ...
THREE PHASE TRANSFORMERS
THREE PHASE TRANSFORMERS

HART 1303 SLO - HCC Learning Web
HART 1303 SLO - HCC Learning Web

... A basic study of electrical motors used in air conditioning and refrigeration including motor winding configuration, type of single phase motor & three phase motor, motor starting devices, operating relays/contactors, safety controls and devices, wiring diagrams, study of different Power supply and ...
< 1 ... 221 222 223 224 225 226 227 228 229 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.