• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electrical Installations 電力裝置
Electrical Installations 電力裝置

RN142ZS12A
RN142ZS12A

... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
Construction of a Simple Transformer to Illustrate Faraday`s Law of
Construction of a Simple Transformer to Illustrate Faraday`s Law of

... described by Oersted's law; [2] and a timevarying magnetic field induces an electromotive force in nearby conductors, which is described by Faraday's law of induction [2]. Mutual inductance occurs when the change in current in one inductor induces a voltage in another nearby inductor. It is importan ...
CSCI 2980: Introduction to Circuits, CAD, and Instrumentation
CSCI 2980: Introduction to Circuits, CAD, and Instrumentation

7SR11 and 7SR12 Argus - Industrial Automation
7SR11 and 7SR12 Argus - Industrial Automation

... busbars, within metal clad switchgear & associated cable boxes. The arc is detected using an optical sensor & the signal input to a protection device which also monitors the load current on the system. A trip signal can be achieved in less than 10 ms using arc detection only or within 20 ms when usi ...
data sheet data sheet - National Model Railroad Association
data sheet data sheet - National Model Railroad Association

SEC 1212G-1225G
SEC 1212G-1225G

Power Supply Tracker Can Also Margin Supplies
Power Supply Tracker Can Also Margin Supplies

high resistance grounding – avoiding
high resistance grounding – avoiding

... ground fault on most 480 V and 600 V solidly grounded systems. The purpose of the code change was to minimize the occurrence of equipment burndowns due to arcing ground faults [1]. Prior to the 1940’s, industrial power systems were ungrounded because the loads were three-wire, and service continuity ...
Short-circuit current rating (SCCR) of industrial control panels
Short-circuit current rating (SCCR) of industrial control panels

fuse theory and operation
fuse theory and operation

... 1. They are designed to continuous load currents. 2. They are designed to interrupt abnormal overcurrents and thereby isolate circuits. 3. Their melting and interrupting time characteristics should be coordinated with other circuit overcurrent protective devices. 4. Just like circuit breakers, they ...
ECE 472 POWER SYSTEMS II EXPERIMENT 4 – WEEK 5 TIME-OVERCURRENT PROTECTION
ECE 472 POWER SYSTEMS II EXPERIMENT 4 – WEEK 5 TIME-OVERCURRENT PROTECTION

ppt
ppt

... of the conductor can be found by •V=BvL • The upper end is at a higher potential than the lower end ...
seminar - Voltimum
seminar - Voltimum

ELG2138 - uOttawa
ELG2138 - uOttawa

... Module 6 (Sections 8.1-8.8): Response of RL and RC Circuits 1st order RL and RC circuits response, switching, stability. Module 7 (Sections 10.1-10.11 & 10.13): Sinusoidal Steady-State Circuit Analysis Response to sinusoidal functions, complex sources, phasors, impedance. Module 8 (Sections 11.1-11. ...
G49045358
G49045358

... DSTATOM for voltage regulation along with neutral current compensation and load balancing of a threephase four-wire load is shown in Fig. 15. The voltages , balanced source currents , load currents , compensator currents , load neutral current , compensator neutral current , source neutral current , ...
Causes of electrical fires
Causes of electrical fires

... In the example above, pushing the receptacle into the work box created a counterclockwise torque on the screw terminal. This torque could loosen the connection if it were not tightened sufficiently. This loose connection may carry current without arcing after installation. However, intermittent curr ...
WATKINS - Chabot College
WATKINS - Chabot College

...  Injuries Typically Occur When: • Procedures Are Inappropriate • Procedures Are Not Followed Or Ignored • Safety Systems Are Circumvented 1866 - Werner Siemens (1816-1892) perfects the dynamo, a generator in which part of the generator's working current is used to power the field windings, eliminat ...
ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008
ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008

... – There is always a risk of electrical hazards whenever you work with power tools or on electrical circuits. – Anyone can be exposed to these hazards either at home or at work. – Serious injury or even death may occur when coming in contact with an electrical voltage that can cause current to flow t ...
PowerPole Presentation, January 2017, David, N8HKU
PowerPole Presentation, January 2017, David, N8HKU

1-1 electric charge
1-1 electric charge

Guide to 600V Generator Set Applications in North America
Guide to 600V Generator Set Applications in North America

lecture3
lecture3

... If a linear circuit is excited by more that one independent source, then the total response is simply the sum of the responses of the individual sources.  Voltage sources - short circuit  Current source - open circuit ...
Fast Opening Switch Approach for High-Voltage Vacuum
Fast Opening Switch Approach for High-Voltage Vacuum

Identification for Electrical Systems
Identification for Electrical Systems

< 1 ... 218 219 220 221 222 223 224 225 226 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.