• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Lecture Notes - Mutual Inductance and Linear Transformers File
Lecture Notes - Mutual Inductance and Linear Transformers File

T ; DC P
T ; DC P

... f) Finally, replace the combination of resistors inside the dashed box with one resistor whose measured value is as close to Re as possible. Theoretically, nothing to the left of the dotted line should change. However, because of the possible inaccuracy of our replacement resistor, small changes are ...
ANSWERS - AP Physics B final Review Packet Section II: Circuits 1
ANSWERS - AP Physics B final Review Packet Section II: Circuits 1

... resistance = r + R/2. The current is then E/(r + R/2) and the total power dissipated in the load is P = I2Rload = (E2R/2)/(r + R/2)2. Using calculus max/min methods or plotting this on a graph gives the value of R for which this equation is maximized of R = 2r. This max/min problem is not part of th ...
DVM with the ICL7106
DVM with the ICL7106

EE 101 Lab 1 Batteries, Power Supplies, and Resistors
EE 101 Lab 1 Batteries, Power Supplies, and Resistors

... of charge is known as an electrical current. A circuit has to be in the form of a loop since the electrical current exiting the power source must exactly balance the electrical current returning to the power source. The dry cell battery is a well-known example of an electrical power source. The batt ...
AN2117
AN2117

... In this slic, the Ring Trip detection is performed sensing the average current (an image of the line current), rectified by a proper circuit, injected in RD resistor. It is then filtered by CAC capacitor and compared to the Ring Trip Threshold (IRTH), internally programmed, by RD resistor itself (pl ...
BMM80 Premium Insulation Multimeters
BMM80 Premium Insulation Multimeters

... The insulation ranges are useful for establishing the integrity of the internal parts such as motors, timers and transformers. The 50 V and 100 V test voltages enable testing of circuits and components where higher voltages can not be tolerated whilst the capacitance range can be used on PCB compone ...
What Do We Know About Stray Voltage?
What Do We Know About Stray Voltage?

... are provided, in part, to reduce damage caused by lightening striking the power lines. The high voltage and low current carried by distribution lines is converted to lower voltage and higher current at the farm transformer. The farm wiring system carries 240 Volt on 2 ‘hot’ or phase wires and 120 Vo ...
Super Mini DIPIPM Ver.6 Series
Super Mini DIPIPM Ver.6 Series

... 3.3 Expanded overload operating range The Ver.6 Series employs a trimming circuit to compensate the characteristics of the short-circuit protection function embedded in the LVIC. As a result, the variance in the detected voltage for short-circuit protection has been reduced from the conventional ±10 ...
LabVIEW************* System for Power Quality Measurement of
LabVIEW************* System for Power Quality Measurement of

Emergency Information - Kirkwood Community College
Emergency Information - Kirkwood Community College

NEX 24 - Schneider Electric
NEX 24 - Schneider Electric

... ●no fragmentation of the enclosure occurs within the time specified for the test ●arcing does not cause holes in the accessible sides up to a height of 2m ●indicators do not ignite due to the effect of the hot gases ●the enclosure remains connected to its earthing point ...
V. Optimization of welding transformer
V. Optimization of welding transformer

Single and Three Phase Overhead Transformer
Single and Three Phase Overhead Transformer

Faraday Disk
Faraday Disk

NA-277 277V to 120V Step Down Transformer
NA-277 277V to 120V Step Down Transformer

... 277V to 120V Step Down Transformer NA-277/300: 300W 277V/120V Step Down Transformer NA-277/150: 150W 277V/120V Step Down Transformer NA-277/100: 100W 277V/120V Step Down Transformer NA-277/50: 50W 277V/120V Step Down Transformer ...
FCL - UFTO Home Page
FCL - UFTO Home Page

... state fault current. These advantages are achieved by employing three phase saturated core fault current limiters with the saturating current provided by a single high efficiency, high current density DC superconducting coil. These superconducting fault current limiters (SCFCL) are still passive dev ...
1 - Brown University
1 - Brown University

... location on the campus. In general, new building loads of 150 KVA and below shall be served from the 4.16 KV distribution system where it is readily available. Loads larger 150 KVA shall be served from the 11.2 KV distribution system. F. In general, building loads on the 4.16 KV distribution systems ...
STK392-040
STK392-040

Selective Wave-Front Based Protection Algorithm for MTDC Systems
Selective Wave-Front Based Protection Algorithm for MTDC Systems

... network etc). Since the voltage and current at the relaying point must fulfil the circuit laws according to Zeq and the incident waves are determined at the fault location, some of the incident waves are in the general case reflected backwards in the negative direction. This implies that the voltage ...
EE2003 Circuit Theory
EE2003 Circuit Theory

... 1. Select the inductor current i and capacitor voltage v as the state variables, making sure they are consistent with the passive sign convention. 2. Apply KCL and KVL to the circuit and obtain circuit variables in terms of state variables. This should lead to a set of first order differential equat ...
Sheath testing, Sheath fault location and Location of
Sheath testing, Sheath fault location and Location of

Magnetism can produce current.
Magnetism can produce current.

... The energy that powers a car comes from burning gasoline, but the car also contains many devices that use electrical energy. Some of them are familiar—the headlights, turn signals, radio, power windows, and door locks. Others may be less familiar, such as the spark plugs that ignite the gasoline, th ...
Chapter 5: Current and Voltage Transformer
Chapter 5: Current and Voltage Transformer

08c_Picture_This
08c_Picture_This

< 1 ... 177 178 179 180 181 182 183 184 185 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report