• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
2.5.4 Emergency Diesel Generator 1.0 Description
2.5.4 Emergency Diesel Generator 1.0 Description

... welded in accordance with ASME Code Section III welding requirements. A report exists and concludes that the piping as indicated in Figure 2.5.4-1 as ASME Code Section III has been hydrostatically tested in accordance with ASME Code Section III requirements. ...
Slide 1
Slide 1

... Fibre & Copper ...
AEMC Ground Resistance Testers
AEMC Ground Resistance Testers

2010 B1 Session Questionnaire ( doc , 67 kB ) - SC B1
2010 B1 Session Questionnaire ( doc , 67 kB ) - SC B1

... Group Meeting SC B1 Insulated Cables, 24th August, 2010 Questionnaire Please return completed Questionnaire at the exit of the meeting room or send it before 30th September, 2010 to : E Bergin (Convenor, Customer Advisory Group, Study Committee B1) ...
A Guide To Diagnostic Insulation Testing Above 1 kV
A Guide To Diagnostic Insulation Testing Above 1 kV

Elec Machinery\US\84\8405
Elec Machinery\US\84\8405

071-75924520-601 Single Wall socket_USBx1_ ESC9
071-75924520-601 Single Wall socket_USBx1_ ESC9

... A fusible resistor was suitably fitted to the primary side of the circuit. Although not a requirement it is recommended that a thermal protective device is incorporated into the circuit. Mechanical Strength (BS 1363-2, Clause 20) -Pass -Fail A standard USB connector was placed in to the socket and s ...
THE SOLLATEK VOLTAGE STABILISER (SVS) RANGE
THE SOLLATEK VOLTAGE STABILISER (SVS) RANGE

Q. What is an arcing fault? A. An arcing fault is the
Q. What is an arcing fault? A. An arcing fault is the

... could be exposed. From this information, the proper personal protective equipment (PPE) can be specified. ...
IMPORTANT SAFETY INSTRUCTION IF 1638 Solar Recombiner, Array Fuse, Disconnect Box
IMPORTANT SAFETY INSTRUCTION IF 1638 Solar Recombiner, Array Fuse, Disconnect Box

... IMPORTANT SAFETY INSTRUCTION SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE SAVE THESE INSTRUCTIONS - This manual contains important instructions for Solar 2.1. DISCLAIMER OF LIABILITY Recombiner Boxes that shall be followed during installation and maintenance for The installation techniques, handling ...
meterman 37xr
meterman 37xr

Investigation of Polarization and Depolarization Current for
Investigation of Polarization and Depolarization Current for

ET 32 (6787)
ET 32 (6787)

... 9.3.1 Super-efficient electric ceiling type fans may also be marked with the ISI certification mark NOTE --- The use of the ISI certification Mark is governed by the provisions of the Indian standards Institution (certification marks) Act and the Rules and Regulations made thereunder. The ISI Mark o ...
P83966
P83966

... National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), Underwriters' Laboratories of Canada (ULC), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire sta ...
Torque Wrenches - Motorq
Torque Wrenches - Motorq

... • A top quality, professional circuit tester with an unbreakable polycarbonate handle and hardened steel probe. • 1.5m heavy duty rubber insulated lead is designed to withstand the toughest garage workshop conditions. • Uses standard automotive bulb for easy replacement. ...
2SK209 Audio Frequency Low Noise Amplifier Applications
2SK209 Audio Frequency Low Noise Amplifier Applications

... spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · The information contained he ...
AL XHHW - Southwire
AL XHHW - Southwire

Diapositive 1
Diapositive 1

... characterization after each series of tests. • Ideally it would be nice to have the OW machine at CERN or to make the investigation at Nikhef by local staff. It is estimated that many iterations are needed. ...
ELECTRICAL EQUIPMENT
ELECTRICAL EQUIPMENT

... converted to direct current by means of the rectifier which is of the very efficient full wave bridge connected type. The main connections in the wiring system are made by rubber socket connectors to the lighting and ignition switches and by individual rubber covered bullet-type push-in connectors. ...
1. General presentation
1. General presentation

... Capacitor units shall be capable of meeting the permissible overload operating conditions as specified in the applicable Standards. ...
V-Guard | Buying Guide for Voltage Stabilizers
V-Guard | Buying Guide for Voltage Stabilizers

... What does a Voltage Stabilizer do? How does it protect your appliances? Stabilizers (often termed as Automatic and Safe Voltage Regulators) are static devises to stabilize your utility voltage before feeding to the connected equipment. It recognizes the voltage fluctuations in the utility and regula ...
Open-circuit Test
Open-circuit Test

... • Secondary are connected in series such that emf's of them are opposite to each other. • Another low voltage supply is connected in series with secondary to get the readings, as shown in the circuit diagram. ...
Nominal 48 V input range - Power Sources Manufacturers Association
Nominal 48 V input range - Power Sources Manufacturers Association

... Most systems include a low input shutdown (LISD) function, to shut down the DC-DC converters if the input voltage falls below the minimum. Assuming the LISD is set to 37±1 V, the minimum voltage at the DC-DC converter is 36 V. At the other extreme, the maximum voltage for a -48 V power system is nor ...
basics_of_branch_cir..
basics_of_branch_cir..

... Testing of the Branch Circuit Finding the Cause of High Impedance • Measure the voltage drop at the furthest receptacle from the panel and record the reading • Repeat this at each receptacle until you find a significant decrease in voltage drop from one receptacle to the next – At that point check ...
USER MANUAL TS21 Craft Test Set Description and
USER MANUAL TS21 Craft Test Set Description and

< 1 ... 57 58 59 60 61 62 63 64 65 ... 171 >

Portable appliance testing



Portable appliance testing (commonly known as ""PAT"", ""PAT Inspection"" or ""PAT Testing"") is the name of a process in the United Kingdom, the Republic of Ireland, New Zealand and Australia by which electrical appliances are routinely checked for safety. The correct term for the whole process is ""in-service inspection & testing of electrical equipment"".Similar procedures exist in other countries, for example, testing of equipment according to DGUV Vorschrift 3 in Germany.Health and safety regulations require that electrical appliances are safe and maintained to prevent harm to workers. Many equipment manufacturers recommend testing at regular intervals to ensure continual safety; the interval between tests depending on both the type of appliance and the environment in which it is to be used. The European Low Voltage Directive governs the manufacture or importation of electrical appliances. Compliance to this has to be declared and indicated by the display of the CE mark on the product. The responsibility for this lies with the manufacturer or the importer and is policed by Trading Standards.Testing equipment has been specifically developed for PAT inspections, based on the testing equipment used by manufacturers to ensure compliance with the British Standard Code of Practice and European product standards relevant to that type of appliance. This in turn allows testing and the interpretation of results to be de-skilled to a large extent. The inspection of the appliances can largely be carried out in-house in many organisations. This can result in cost savings and more flexibility as to exactly when a PAT is carried out.