UNIT 10
... diagram. This is so because there is negligible current through RG and hence practically no voltage across it. Both ends of RG have the same voltage, namely that of the lower end of RS i.e. 'ground' or 0 V. The source is therefore at a higher voltage than the gate, i.e. the gate is negative with res ...
... diagram. This is so because there is negligible current through RG and hence practically no voltage across it. Both ends of RG have the same voltage, namely that of the lower end of RS i.e. 'ground' or 0 V. The source is therefore at a higher voltage than the gate, i.e. the gate is negative with res ...
Ultra-Low Noise Amplifier
... Ultra-Low Noise Amplifier The COMLINEAR CLC1002(single) is a high-performance, voltage feedback amplifier with ultra-low input voltage noise, 0.6nV/√Hz. The CLC1002 provides 965MHz gain bandwidth product and 170V/μs slew rate making it well suited for high-speed data acquisition systems requiri ...
... Ultra-Low Noise Amplifier The COMLINEAR CLC1002(single) is a high-performance, voltage feedback amplifier with ultra-low input voltage noise, 0.6nV/√Hz. The CLC1002 provides 965MHz gain bandwidth product and 170V/μs slew rate making it well suited for high-speed data acquisition systems requiri ...
Energy Management System
... data of only a single outlet), which makes it less of a full home solution. More advanced Kill-Awatt units also provide graphical analysis of power consumption. Many power companies, such as RGE, will provide web access to usage data for customers. As they have only black box access, the data availa ...
... data of only a single outlet), which makes it less of a full home solution. More advanced Kill-Awatt units also provide graphical analysis of power consumption. Many power companies, such as RGE, will provide web access to usage data for customers. As they have only black box access, the data availa ...
Catalogue 3.10
... signals into a digital format. Inputs and outputs are isolated. On modules with voltage inputs, it is possible to set the maximum input signal using a trimmer. The unit 44097 is suitable for both positive and negative input signals. The output "POL" indicates the polarity (log 1 = Positive). A volta ...
... signals into a digital format. Inputs and outputs are isolated. On modules with voltage inputs, it is possible to set the maximum input signal using a trimmer. The unit 44097 is suitable for both positive and negative input signals. The output "POL" indicates the polarity (log 1 = Positive). A volta ...
HID Proxpro Brochure.4p - Envoy Data Corporation
... electrical box. With its inherently weatherproof design, the reader is easily mounted either indoors or out. Using advanced surface-mount technology manufacturing techniques, the ProxPro reader offers high reliability, consistent read range characteristics, and low power consumption in a single, eas ...
... electrical box. With its inherently weatherproof design, the reader is easily mounted either indoors or out. Using advanced surface-mount technology manufacturing techniques, the ProxPro reader offers high reliability, consistent read range characteristics, and low power consumption in a single, eas ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... information technology. Power- system design for these applications has long been dominated by such issues as efficiency, thermal management, voltage regulation, reliability, power density, and cost. Going forward, these factors will remain critical. A typical breakdown of electricity use and power ...
... information technology. Power- system design for these applications has long been dominated by such issues as efficiency, thermal management, voltage regulation, reliability, power density, and cost. Going forward, these factors will remain critical. A typical breakdown of electricity use and power ...
Experiment 8 - Signal Waveforms and Measurements
... "constant" signals. It is possible to refer a constant voltage as DC voltage, or similarly a constant current as DC current. The waveform of a 10 volt DC voltage is plotted in Fig.8.1. ...
... "constant" signals. It is possible to refer a constant voltage as DC voltage, or similarly a constant current as DC current. The waveform of a 10 volt DC voltage is plotted in Fig.8.1. ...
PlasmaCAM DHC 2 ™ CNC Plasma Profiling System
... Hand torch configuration with 25' cord is recommended (minimum is 15'). (Expensive “machine torch” is not needed—hand torch cuts with the same parts just as well.) An angled handle (like 70°) is preferred over a straight 90° handle, although either style will work well. “Contact” arc starting mechan ...
... Hand torch configuration with 25' cord is recommended (minimum is 15'). (Expensive “machine torch” is not needed—hand torch cuts with the same parts just as well.) An angled handle (like 70°) is preferred over a straight 90° handle, although either style will work well. “Contact” arc starting mechan ...
8.0 A, 400 V NPN Bipolar Power Transistor
... turn−off load line within the Reverse Bias SOA curve. Load lines that fall within the pulsed forward biased SOA curve during turn−on and within the reverse bias SOA curve during turn−off are considered safe, with the following ...
... turn−off load line within the Reverse Bias SOA curve. Load lines that fall within the pulsed forward biased SOA curve during turn−on and within the reverse bias SOA curve during turn−off are considered safe, with the following ...
DS18S20 High-Precision 1-Wire Digital Thermometer FEATURES
... temperature conversions or copying data from the scratchpad memory to EEPROM, the operating current can be as high as 1.5mA. This current can cause an unacceptable voltage drop across the weak 1-Wire pullup resistor and is more current than can be supplied by CPP. To assure that the DS18S20 has suff ...
... temperature conversions or copying data from the scratchpad memory to EEPROM, the operating current can be as high as 1.5mA. This current can cause an unacceptable voltage drop across the weak 1-Wire pullup resistor and is more current than can be supplied by CPP. To assure that the DS18S20 has suff ...
General Description Features
... deasserting the outputs during margin testing. The MAX16001/MAX16002/MAX16004–MAX16007 offer a watchdog timer that asserts RESET or an independent watchdog output (MAX16005) when the watchdog timeout period (1.6s typ) is exceeded. The watchdog timer can be disabled by leaving the input open. ...
... deasserting the outputs during margin testing. The MAX16001/MAX16002/MAX16004–MAX16007 offer a watchdog timer that asserts RESET or an independent watchdog output (MAX16005) when the watchdog timeout period (1.6s typ) is exceeded. The watchdog timer can be disabled by leaving the input open. ...
Lab#5-Voltmeter
... 1. Measure and record the input resistance of the analog movement. Be sure to also record what number movement you are using. You will want to use the same movement for all of your experiments. Observe what happens to the movement's needle when you connect it to the DMM: record the reading of the an ...
... 1. Measure and record the input resistance of the analog movement. Be sure to also record what number movement you are using. You will want to use the same movement for all of your experiments. Observe what happens to the movement's needle when you connect it to the DMM: record the reading of the an ...
Measuring Low Resistance Devices with High Current
... set of leads called sense leads. Although some small current may flow through the sense leads, it is usually negligible and can generally be ignored for all practical purposes. ...
... set of leads called sense leads. Although some small current may flow through the sense leads, it is usually negligible and can generally be ignored for all practical purposes. ...
FPF1013 / FPF1014 IntelliMAX™ 1 V-Rated
... The FPF1013/4 are low-RDS(ON) N-channel load switches with controlled turn-on. The core of each device is a 17 mΩ (VIN = 1 V, VON = 3 V) N-channel MOSFET and is customized for a low-input operating range of 0.8 V to 1.8 V. The ON pin controls the state of the switch. The FPF1014 contains a 60 Ω (typ ...
... The FPF1013/4 are low-RDS(ON) N-channel load switches with controlled turn-on. The core of each device is a 17 mΩ (VIN = 1 V, VON = 3 V) N-channel MOSFET and is customized for a low-input operating range of 0.8 V to 1.8 V. The ON pin controls the state of the switch. The FPF1014 contains a 60 Ω (typ ...
High-Speed and High-Precision Current Winner-Take
... rapidly falls, causing cell to be a winner. Note, that the presented voltages are the cell outputs before the inverter, thus the circuit real response time is faster than indicated in Fig. 2. Table I summarizes the main characteristics of the circuit, as were carried out by simulations. Note that mi ...
... rapidly falls, causing cell to be a winner. Note, that the presented voltages are the cell outputs before the inverter, thus the circuit real response time is faster than indicated in Fig. 2. Table I summarizes the main characteristics of the circuit, as were carried out by simulations. Note that mi ...
NCP5663 - Low Output Voltage, Ultra
... OSCON with an Equivalent Series Resistance (ESR) of 50 mW. It is especially required if the power source is located more than a few inches from the NCP5663/NCV5663. This capacitor will reduce device sensitivity and enhance the output transient response time. The PCB layout is very important and in o ...
... OSCON with an Equivalent Series Resistance (ESR) of 50 mW. It is especially required if the power source is located more than a few inches from the NCP5663/NCV5663. This capacitor will reduce device sensitivity and enhance the output transient response time. The PCB layout is very important and in o ...
CMS2005 - Sensitec GmbH
... (located at the centre of the primary conductor) should be below 1 kA/m and 15 (A/m)/mm (18.7 µT/mm), respectively. Generally, shielding is possible to avoid influence of magnetic stray fields. Example: A conductor carrying 1 A generates a magnetic field of 20 A/m and a magnetic field gradient of 2 ...
... (located at the centre of the primary conductor) should be below 1 kA/m and 15 (A/m)/mm (18.7 µT/mm), respectively. Generally, shielding is possible to avoid influence of magnetic stray fields. Example: A conductor carrying 1 A generates a magnetic field of 20 A/m and a magnetic field gradient of 2 ...
Advanced Protection, Automation, and Control Functions
... relay always assigns the transferring feeder to the correct zone or zones and maintains high-speed bus protection, and the CT secondaries do not need to be switched. Combining a higher sampling rate with a greater number of analog inputs allows for some very innovative protection schemes that not on ...
... relay always assigns the transferring feeder to the correct zone or zones and maintains high-speed bus protection, and the CT secondaries do not need to be switched. Combining a higher sampling rate with a greater number of analog inputs allows for some very innovative protection schemes that not on ...