LTC6802-2 - Multicell Addressable Battery Stack Monitor
... GPIO1, GPIO2 (Pins 35, 36): General Purpose Input/Output. The operation of these pins depends on the state of the MMB pin. When MMB is high, the pins behave as traditional GPIOs. By writing a “0” to a GPIO configuration register bit, the open drain output is activated and the pin is pulled to V–. By ...
... GPIO1, GPIO2 (Pins 35, 36): General Purpose Input/Output. The operation of these pins depends on the state of the MMB pin. When MMB is high, the pins behave as traditional GPIOs. By writing a “0” to a GPIO configuration register bit, the open drain output is activated and the pin is pulled to V–. By ...
CAG/PSG CD-ROM
... Power Systems (IPS) Isolated Power Systems (IPS) were first introduced into the hospital environment as a means of reducing the risk of explosions in operating rooms and other areas containing or using flammable anesthetizing agents. The IPS functions by “floating” the secondary power lines so that ...
... Power Systems (IPS) Isolated Power Systems (IPS) were first introduced into the hospital environment as a means of reducing the risk of explosions in operating rooms and other areas containing or using flammable anesthetizing agents. The IPS functions by “floating” the secondary power lines so that ...
DS90LV031A 3V LVDS Quad CMOS Differential Line Driver General Description
... ground as shown in Figure 6. Note that the steady-state voltage (VSS) peak-to-peak swing is twice the differential voltage (VOD) and is typically 700 mV. The current mode driver provides substantial benefits over voltage mode drivers, such as an RS-422 driver. Its quiescent current remains relativel ...
... ground as shown in Figure 6. Note that the steady-state voltage (VSS) peak-to-peak swing is twice the differential voltage (VOD) and is typically 700 mV. The current mode driver provides substantial benefits over voltage mode drivers, such as an RS-422 driver. Its quiescent current remains relativel ...
BDTIC CoolSET -Q1 www.BDTIC.com/infineon
... and a comparator. These three parts are key to implement digital frequency reduction with decreasing load. In addition, a ringing suppression time controller is implemented to avoid mistriggering by the high frequency oscillation, when the output voltage is very low under conditions such as soft sta ...
... and a comparator. These three parts are key to implement digital frequency reduction with decreasing load. In addition, a ringing suppression time controller is implemented to avoid mistriggering by the high frequency oscillation, when the output voltage is very low under conditions such as soft sta ...
Acrobat Distiller, Job 62 - Genetic Programming Inc.
... Abstract: Analog electrical circuits that perform mathematical functions (e.g., cube root, square) are called computational circuits. Computational circuits are of special practical importance when the small number of required mathematical functions does not warrant converting an analog signal into ...
... Abstract: Analog electrical circuits that perform mathematical functions (e.g., cube root, square) are called computational circuits. Computational circuits are of special practical importance when the small number of required mathematical functions does not warrant converting an analog signal into ...
01.4IB.60100B Ground-Gard High Resistance
... the high resistance grounding assembly (HRG). Each user has the responsibility to instruct and supervise all personnel associated with usage, installation, operation, and maintenance of this equipment on all safety procedures. Furthermore, each user has the responsibility of establishing a safety pr ...
... the high resistance grounding assembly (HRG). Each user has the responsibility to instruct and supervise all personnel associated with usage, installation, operation, and maintenance of this equipment on all safety procedures. Furthermore, each user has the responsibility of establishing a safety pr ...
OPA341 OPA2341 SINGLE-SUPPLY, RAIL-TO-RAIL OPERATIONAL AMPLIFIER WITH SHUTDOWN
... OPA341 series op amps are optimized for driving medium speed (up to 100kHz) sampling A/D converters. However, they also offer excellent performance for higher-speed converters. The OPA341 series provides an effective means of buffering the A/D converter’s input capacitance and resulting charge injec ...
... OPA341 series op amps are optimized for driving medium speed (up to 100kHz) sampling A/D converters. However, they also offer excellent performance for higher-speed converters. The OPA341 series provides an effective means of buffering the A/D converter’s input capacitance and resulting charge injec ...
lecture4
... To measure voltage, we use a two-terminal device called a voltmeter. To measure current, we use a two-terminal device called a ammeter. To measure resistance, we use a two-terminal device called a ohmmeter. A multimeter can be setup to function as any of these three devices. In lab, you use a DMM to ...
... To measure voltage, we use a two-terminal device called a voltmeter. To measure current, we use a two-terminal device called a ammeter. To measure resistance, we use a two-terminal device called a ohmmeter. A multimeter can be setup to function as any of these three devices. In lab, you use a DMM to ...
Old Company Name in Catalogs and Other Documents
... operation will establish when the both inputs are within the Common Mode Input Voltage Range of electrical characteristics. 3. This specification is the voltage which should be allowed to supply to the output terminal from external without damage or destructive. Even during the transition period of ...
... operation will establish when the both inputs are within the Common Mode Input Voltage Range of electrical characteristics. 3. This specification is the voltage which should be allowed to supply to the output terminal from external without damage or destructive. Even during the transition period of ...
MAX961–MAX964/ MAX997/MAX999 Single/Dual/Quad, Ultra
... The MAX961–MAX964/MAX997/MAX999 are low-power, ultra-high-speed comparators with internal hysteresis. These devices are optimized for single +3V or +5V operation. The input common-mode range extends 100mV Beyond-theRails™, and the outputs can sink or source 4mA to within 0.52V of GND and VCC. Propag ...
... The MAX961–MAX964/MAX997/MAX999 are low-power, ultra-high-speed comparators with internal hysteresis. These devices are optimized for single +3V or +5V operation. The input common-mode range extends 100mV Beyond-theRails™, and the outputs can sink or source 4mA to within 0.52V of GND and VCC. Propag ...
AN-162 LM2907 Tachometer/Speed Switch Building Block
... with signals referenced to ground. Q7, Q8, D4, and D5 comprise an active load with positive feedback. This load behaves as a bi-stable flip-flop which may be set or reset depending upon the currents supplied from Q2 and Q3. Consider the situation where Q2 and Q3 are conducting equally, i.e. the inpu ...
... with signals referenced to ground. Q7, Q8, D4, and D5 comprise an active load with positive feedback. This load behaves as a bi-stable flip-flop which may be set or reset depending upon the currents supplied from Q2 and Q3. Consider the situation where Q2 and Q3 are conducting equally, i.e. the inpu ...
MAX3050/MAX3057 ±80V Fault-Protected, 2Mbps, Low Supply Current CAN Transceivers General Description
... mode, supply current is reduced to 125µA. In shutdown mode, supply current is 15µA. CANH and CANL are output short-circuit current limited and are protected against excessive power dissipation by thermal-shutdown circuitry that places the driver outputs into a high-impedance state. ...
... mode, supply current is reduced to 125µA. In shutdown mode, supply current is 15µA. CANH and CANL are output short-circuit current limited and are protected against excessive power dissipation by thermal-shutdown circuitry that places the driver outputs into a high-impedance state. ...
MAX16914/MAX16915 Ideal Diode, Reverse-Battery, and Overvoltage Protection Switch/Limiter Controllers with External MOSFETs
... With an overvoltage threshold (VOV) set to 20V, RTOTAL < 20V/(100 x ISET), where ISET = 1FA (max). ...
... With an overvoltage threshold (VOV) set to 20V, RTOTAL < 20V/(100 x ISET), where ISET = 1FA (max). ...
IMPLEMENTATION OF INTEGRAL SWITCHING CYCLE CONTROL
... The need of customer can be satisfied only when easily operated, reliable, energy saving, reasonable cost products are introduced in the market. With these requirements as the main aim, industries are forced to know about the development and advancement in the technology. The loads are made efficien ...
... The need of customer can be satisfied only when easily operated, reliable, energy saving, reasonable cost products are introduced in the market. With these requirements as the main aim, industries are forced to know about the development and advancement in the technology. The loads are made efficien ...
STLC3080
... If required , the ringing relay drive signal RELR can be synchronised to a clock applied to CKRING input. This clock is derived from the ringing signal with proper time delay, according to the activation/deactivation time of the relay. RELR is activated on the low level of CKRING clock. The duty cyc ...
... If required , the ringing relay drive signal RELR can be synchronised to a clock applied to CKRING input. This clock is derived from the ringing signal with proper time delay, according to the activation/deactivation time of the relay. RELR is activated on the low level of CKRING clock. The duty cyc ...
AM-560 AM-570 AM-540-EUR AM-550-EUR
... requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe®. In-Warranty Repairs and Replacement – All Countries Please read th ...
... requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe®. In-Warranty Repairs and Replacement – All Countries Please read th ...
PCS100 AVC-20 Technical Catalogue
... Faults downstream of voltage regulators can have an impact on other downstream loads. The PCS100 AVC-20 is designed to integrate into your plant’s fault protection scheme with its ability to allow 2000% current to flow for 200 milliseconds to clear downst ream faults, without disruption to other equ ...
... Faults downstream of voltage regulators can have an impact on other downstream loads. The PCS100 AVC-20 is designed to integrate into your plant’s fault protection scheme with its ability to allow 2000% current to flow for 200 milliseconds to clear downst ream faults, without disruption to other equ ...
TSM102 TSM102A DUAL OPERATIONAL AMPLIFIER, DUAL COMPARATOR, AND VOLTAGE REFERENCE
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
MAX2654-56 - Maxim Integrated
... The MAX2654/MAX2655/MAX2656 high third-order intercept point (IP3), low-noise amplifiers (LNAs) are designed for applications in GPS, PCS, WLL, and satellite phone systems. The MAX2654/MAX2655/MAX2656 incorporate on-chip internal output matching to 50Ω, eliminating the need for external matching com ...
... The MAX2654/MAX2655/MAX2656 high third-order intercept point (IP3), low-noise amplifiers (LNAs) are designed for applications in GPS, PCS, WLL, and satellite phone systems. The MAX2654/MAX2655/MAX2656 incorporate on-chip internal output matching to 50Ω, eliminating the need for external matching com ...