• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fluke 120B Series Industrial ScopeMeter® Hand
Fluke 120B Series Industrial ScopeMeter® Hand

Single-Supply, 10MHz, Rail-to-Rail Output, Low-Noise, JFET Amplifier OPA141 OPA2141
Single-Supply, 10MHz, Rail-to-Rail Output, Low-Noise, JFET Amplifier OPA141 OPA2141

... Junction-to-board characterization parameter (6) ...
4.3. Inverse Class F with quarterwave transmission line
4.3. Inverse Class F with quarterwave transmission line

... 2]. It was shown that the symmetrical anode current waveform and level of its depression can be provided with the opposite phase conditions between the fundamental-frequency and second harmonic components and an optimum value of the ratio between their voltage amplitudes. It was noted that high oper ...
2SAR562F3
2SAR562F3

USB Dedicated Charging Port Controller and Power Switch (Rev. A)
USB Dedicated Charging Port Controller and Power Switch (Rev. A)

... Connected to the D– or D+ line of USB connector. Provide the correct voltage with an attached portable equipment for DCP detection, high impedance while disabled. ...
µ OPA349 OPA2349 1
µ OPA349 OPA2349 1

... Signal Input Terminals, Voltage(2) .................. (V–) – 0.5V to (V+) + 0.5V Current(2) .................................................... 10mA Output Short Circuit(3) .............................................................. Continuous Operating Temperature, OPA2349 ..................... ...
LTC1065 - DC Accurate, Clock-Tunable Linear Phase 5th Order
LTC1065 - DC Accurate, Clock-Tunable Linear Phase 5th Order

... is primarily intended for generation of clock frequencies below 500kHz. The first curve of the Typical Performance Characteristics section shows how to quickly choose the value of the RC for a given frequency. More precisely, the frequency of the internal oscillator is equal to: fCLK = K/RC For cloc ...
MAX11156 18-Bit, 500ksps, ±5V SAR ADC with Internal Reference in TDFN General Description
MAX11156 18-Bit, 500ksps, ±5V SAR ADC with Internal Reference in TDFN General Description

... small size, and internal reference. The MAX11156 measures a ±5V (10VP-P) input range while operating from a single 5V supply. A patented charge-pump architecture allows direct sampling of high- impedance sources. The MAX11156 integrates an optional 6ppm/°C reference with internal buffer, saving the ...
Quadra (VL-1000 750 Kb)
Quadra (VL-1000 750 Kb)

... antennas for different bands. Extensive self-test, system monitoring, and protection circuits are provided, with status and tuning information being displayed on a huge Liquid Crystal Display ...
AAT3155 数据资料DataSheet下载
AAT3155 数据资料DataSheet下载

4 And 6 Tube Nixie Clock Kit Assembly Instructions
4 And 6 Tube Nixie Clock Kit Assembly Instructions

... 30) Quality check: Review the board and look for any missing or bad solder joints. Confirm that the zener diode has its strip towards the top of the board. Confirm the the rectifier has its strip on the right. Confirm that the physically smaller 100uF capacitor has its strip toward the bottom of th ...
MAX14970 Ruggedized 6Gbps SATA Redriver with High ESD and Extended Temperature Operation
MAX14970 Ruggedized 6Gbps SATA Redriver with High ESD and Extended Temperature Operation

... output levels. Each buffer includes an equalizer, a limiting amplifier, and an output driver with preemphasis. The buffer outputs are protected from high-voltage electrostatic discharge (ESD) to Q8kV Human Body Model (HBM). ...
AAT3157 数据资料DataSheet下载
AAT3157 数据资料DataSheet下载

Here - Spellman High Voltage
Here - Spellman High Voltage

49`er Availability
49`er Availability

... Some things to keep in mind if you build one: * The limited VXO range has to do with how far you can pull an NE602 oscillator without having it stop. I used an RF choke, but you can increase the pull with a large toroid (like 60 turns or more on a T68-2 or T68-6). But be careful at the low end of yo ...
AD595 Datasheet - SparkFun Electronics
AD595 Datasheet - SparkFun Electronics

... power and signal common at Pin 4. The thermocouple wire inputs connect to Pins 1 and 14 either directly from the measuring point or through intervening connections of similar thermocouple wire type. When the alarm output at Pin 13 is not used it should be connected to common or –V. The precalibrated ...
- aes journals
- aes journals

... ABSTRACT: 4-bit 5GS flash ADC in 0.18µm CMOS is presented. All the ADC sub blocks including the comparators and the encoder are implemented using current mode logic (CML) circuits. In addition to CML implementation comparator and encoder are fully pipelined to improve the conversion rate. Encoder is ...
MAX9476 - Part Number Search
MAX9476 - Part Number Search

... synthesizer can be used to generate the clocks for systems using T1, E1, T3, E3, and xDSL. The MAX9476 features a phase-lock loop (PLL) that uses a voltage-controlled crystal oscillator (VCXO). The internal PLL phase locks the external crystal (35.328MHz) to the 8kHz input reference clock. In additi ...
Technical specification - DAE e
Technical specification - DAE e

... set value by varying the width of the pulses in open loop operation. vi. Soft start feature: When the VFD is started, the frequency of inverter shall be increased from minimum to SET value, gradually according to set ramp rate (soft start feature).Voltage shall ramp upward but rampdown feature is no ...
Series 36 Electric Actuator
Series 36 Electric Actuator

HOW TO CHECK SERVOPACK
HOW TO CHECK SERVOPACK

... back of the unit. If the cooling fan is not working properly, the servo will trip on an overheat fault. Visually check the cooling fan to make sure it turns freely. If there is no physical evidence that the fan is bad, the motor can be checked with an ohmmeter. Using an ohmmeter, measure across the ...
Basic Wiring for Motor Contol
Basic Wiring for Motor Contol

... Common Control is when the power circuit and the control circuit are fed from the same voltage source. Common control is when the control circuit is tied back to lines 1 and 2 of of the starter. It is supplied with the same voltage as the power or motor circuit. The understanding of Common Control a ...
Contents 1 Introduction
Contents 1 Introduction

PAM8006A Description Pin Assignments
PAM8006A Description Pin Assignments

... tolerance on this trip point from device to device. Once the die temperature exceeds the set thermal point, the device enters into the shutdown state and the outputs are disabled. This is not a latched fault. The thermal fault is cleared once the temperature of the die is reduced by 50°C. The device ...
User Manual
User Manual

... This receptacle is for the connection of the DUT. The Receptacle Rating depends on the specific Analyzer model. SA-2010 models use a Hospital Grade North American/USA standard NEMA 5-20R receptacle rated 20 Amps @ 125 VAC. SA2010-INTL models use a universal international receptacle rated 20 Amps @ 2 ...
< 1 ... 341 342 343 344 345 346 347 348 349 ... 1306 >

Immunity-aware programming

When writing firmware for an embedded system, immunity-aware programming refers to programming techniques which improve the tolerance of transient errors in the program counter or other modules of a program that would otherwise lead to failure. Transient errors are typically caused by single event upsets, insufficient power, or by strong electromagnetic signals transmitted by some other ""source"" device.Immunity-aware programming is an example of defensive programming and EMC-aware programming. Although most of these techniques apply to the software in the ""victim"" device to make it more reliable, a few of these techniques apply to software in the ""source"" device to make it emit less unwanted noise.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report