• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX44242 20V, Low Input Bias-Current, Low-Noise, Dual Op Amplifier General Description
MAX44242 20V, Low Input Bias-Current, Low-Noise, Dual Op Amplifier General Description

... a noninverting amplifier is typically used to buffer and/or ...
Low Input Voltage Step-Up Converter in Thin SOT
Low Input Voltage Step-Up Converter in Thin SOT

... the control circuit properly a startup oscillator starts to operate the switches. During this phase the switching frequency is controlled by the oscillator and the maximum switch current is limited. As soon as the device has built up the output voltage to about 1.8 V, high enough for supplying the c ...
Comparison between NERC VAR-001-1a and Alberta VAR-001-AB-1a Voltage and Reactive Control
Comparison between NERC VAR-001-1a and Alberta VAR-001-AB-1a Voltage and Reactive Control

... Proposed Terms for the Consolidated Authoritative Document Glossary 3 : “aggregated generating facilities” means an aggregation of generating units, including any reactive power resources, which are: (i) designated by the ISO; and (ii) situated in the same proximate location at one or more point of ...
P82623
P82623

... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
Terminal Connections Visual Indicators Models Covered Mounting
Terminal Connections Visual Indicators Models Covered Mounting

... accept wire sizes between #14 and #22 AWG. Terminals are labeled in the non-powered (fault) condition. FAI Input (if present) - Locate the FAI input terminals. These terminals are non-removable and accept wire sizes between #14 and #22 AWG. The FAI input accepts a dry contact input to control the DC ...
Experiment 7 - Rensselaer Polytechnic Institute
Experiment 7 - Rensselaer Polytechnic Institute

... 741, and is not used. Op-amp limitations: Just like all real circuit elements, op-amps have certain limitations which prevent them from performing optimally under all conditions. The one you are most likely to encounter in this class is called saturation. An op amp becomes saturated if it tries to p ...
AD96685 数据手册DataSheet 下载
AD96685 数据手册DataSheet 下载

... cause the output to oscillate (possibly affecting the other comparator which is being used) unless the output is forced into a fixed state. This is easily accomplished by ensuring that the two inputs are at least one diode drop apart, while also grounding the LATCH ENABLE input. The best performance ...
3.3V-Powered, ±15kV ESD-Protected, 12Mbps and Slew-Rate-Limited True RS-485/RS-422 Transceivers MAX3483E/MAX3485E/MAX3486E/MAX3488E/MAX3490E/MAX3491E General Description
3.3V-Powered, ±15kV ESD-Protected, 12Mbps and Slew-Rate-Limited True RS-485/RS-422 Transceivers MAX3483E/MAX3485E/MAX3486E/MAX3488E/MAX3490E/MAX3491E General Description

... Devices in the MAX3483E family (MAX3483E/MAX3485E/ MAX3486E/MAX3488E/MAX3490E/MAX3491E) are ±15kV ESD-protected, +3.3V, low-power transceivers for RS-485 and RS-422 communications. Each device contains one driver and one receiver. The MAX3483E and MAX3488E feature slew-rate-limited drivers that mini ...
BD9E151NUX
BD9E151NUX

... must meet the absolute maximum ratings for the application: Reverse voltage must be higher than the maximum voltage at the LX pin, which is VINMAX + 0.5 V. Peak current must be greater than IOUTMAX+⊿IL plus on half the peak to peak inductor current. Forward voltage drop should be small for higher ef ...
TDA8954 1. General description 2
TDA8954 1. General description 2

... When OCP is activated, the active power transistor is turned off and the other power transistor is turned on to reduce the current (CPROT is partially discharged). Normal operation is resumed at the next switching cycle (CPROT is recharged). CPROT is partially discharge each time OCP is activated du ...
380VDC 6-Lamp Ballast Retrofit Installation and Userʼs Manual NB380-T832-06-ISBL
380VDC 6-Lamp Ballast Retrofit Installation and Userʼs Manual NB380-T832-06-ISBL

... pursuant to Part 18 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual ...
DS2480B
DS2480B

... port and its timing as well as the communication speed at both the port and the 1-Wire bus are configurable. The circuit to achieve these functions is outlined in the block diagram (see Figure 1). The device gets its input data from the serial communication port of the host computer through pin TXD. ...
Chapter 9: Transmission Lines
Chapter 9: Transmission Lines

... grid on; figure(2); plot(power/1e6,delta,'b-','LineWidth',2.0); xlabel('\bfPower (MW)'); ylabel('\bfAngle \delta (deg)'); title ('\bfAngle \delta vs Power Supplied'); grid on; ...
Transformers plays a crucial role in the power
Transformers plays a crucial role in the power

Before You Begin: Assign Information Classification
Before You Begin: Assign Information Classification

... © 2006 Cisco Systems, Inc. All rights reserved. ...
bq2970 Li-Ion/Li Polymer Battery Protection IC (Rev. D)
bq2970 Li-Ion/Li Polymer Battery Protection IC (Rev. D)

... Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to ab ...
LM358-N 数据资料 dataSheet 下载
LM358-N 数据资料 dataSheet 下载

... of power supply voltage with little change in performance characteristics. At 25˚C amplifier operation is possible down to a minimum supply voltage of 2.3 VDC. Precautions should be taken to insure that the power supply for the integrated circuit never becomes reversed in polarity or that the unit i ...
Test Procedure for the NCN4555GEVB  Table 1: Required Equipment 12/27/2005
Test Procedure for the NCN4555GEVB Table 1: Required Equipment 12/27/2005

...  CLK and SIM_CLK are clock signals (Figures 9 and 10).  Connect the RST input to the Ground or to VDD in order to avoid floating nodes.  To evaluate SIM_CLK a clock signal has to be connected either using the external clock input (SMB connector) or through the HE10 connector. The selection is don ...
Siemens Sinamics V20 Getting Started
Siemens Sinamics V20 Getting Started

... Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo ...
DS1882 Dual Log Audio Digital Potentiometer General Description Features
DS1882 Dual Log Audio Digital Potentiometer General Description Features

... IDD is specified with SDA = SCL = CE = VDD, resistor pins floating, and digital inputs connected to VDD or GND. ICC is specified with SDA = SCL = CE = VDD, resistor pins floating, and digital inputs connected to VDD or GND, after zerocrossing detection has timed out. Note 5: The DS1882 will not obst ...
FSA2380 — Low RON (0.75 W) 3:1 Negative Swing Audio Source
FSA2380 — Low RON (0.75 W) 3:1 Negative Swing Audio Source

... Unless otherwise specified in this data sheet, this product is a standard commercial product and is not intended for use in applications that require extraordinary levels of quality and reliability. This product may not be used in the following applications, unless specifically approved in writing b ...
Fault Analysis on Distribution Feeders With Distributed Generators
Fault Analysis on Distribution Feeders With Distributed Generators

... Fig. 4(b) shows the initial current transients of the voltage controlled IIDG during the first few cycles of the fault. Since the current varies considerably during this period, DG needs to be represented in enough detail so that the controller’s response can be taken into account and the peak curre ...
A1147 and A1148: Low Current Ultrasensitive Two
A1147 and A1148: Low Current Ultrasensitive Two

... against overvoltage conditions on the supply line. The output currents of the A1148 switches HIGH in the presence of a south (+) polarity magnetic field of sufficient strength, and switches LOW otherwise, as in the presence of a weak field or a north (–) polarity field. The A1147 has an opposite out ...
Device Maintenance as it relates to the Arc Flash Hazard
Device Maintenance as it relates to the Arc Flash Hazard

... Molded-case circuit breakers receive extensive testing and calibration at the manufacturers’ plants. These tests are performed in accordance with UL 489, Standard for Safety, MoldedCase Circuit Breakers, Molded-Case Switches and Circuit Breaker Enclosures. Molded-case circuit breakers, other than t ...
LMG5200 80V, 10A GaN Half-Bridge Power Stage
LMG5200 80V, 10A GaN Half-Bridge Power Stage

... The LMG5200 device is available in a 6 mm × 8 mm × 2 mm lead-free package and can be easily mounted on PCBs. The TTL logic compatible inputs can withstand input voltages up to 12 V regardless of the VCC voltage. The proprietary bootstrap voltage clamping technique ensures the gate voltages of the en ...
< 1 ... 334 335 336 337 338 339 340 341 342 ... 1306 >

Immunity-aware programming

When writing firmware for an embedded system, immunity-aware programming refers to programming techniques which improve the tolerance of transient errors in the program counter or other modules of a program that would otherwise lead to failure. Transient errors are typically caused by single event upsets, insufficient power, or by strong electromagnetic signals transmitted by some other ""source"" device.Immunity-aware programming is an example of defensive programming and EMC-aware programming. Although most of these techniques apply to the software in the ""victim"" device to make it more reliable, a few of these techniques apply to software in the ""source"" device to make it emit less unwanted noise.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report