Design of a New External Signal Controlled Polymorphic
... digital circuit. Often this can be found having two inputs and one output. With different system state and requirements, every terminal is in one of the two binary conditions low (0) or high (1), represented by different voltage levels. ...
... digital circuit. Often this can be found having two inputs and one output. With different system state and requirements, every terminal is in one of the two binary conditions low (0) or high (1), represented by different voltage levels. ...
James Samual`s Thesis Proposal
... the circuitry. As a result, PowerToad can potentially burn a person or even start a fire. In order to ...
... the circuitry. As a result, PowerToad can potentially burn a person or even start a fire. In order to ...
VSP2590 数据资料 dataSheet 下载
... The data shift operation should decode at the rising edge of SCLK while SLOAD is low. 16 bits of input data are loaded to the parallel latch in the VSP2590 at the rising edge of SCS. External Sync Update: Register update timing is synchronized with the falling edge of UPDATE_REG. Continuous Writing ...
... The data shift operation should decode at the rising edge of SCLK while SLOAD is low. 16 bits of input data are loaded to the parallel latch in the VSP2590 at the rising edge of SCS. External Sync Update: Register update timing is synchronized with the falling edge of UPDATE_REG. Continuous Writing ...
Juice Box Users Manual
... Connect the Juice Box to a network switch that your computer has access to. (Or use a cross over cable with a direct connection). The Juice Box network connector is the RJ45 jack on the right side of the chassis above the DB9 connector. Open your Web browser and type “http://” and the IP address of ...
... Connect the Juice Box to a network switch that your computer has access to. (Or use a cross over cable with a direct connection). The Juice Box network connector is the RJ45 jack on the right side of the chassis above the DB9 connector. Open your Web browser and type “http://” and the IP address of ...
Product manual for the 4-Quadrant-/ Combi meter
... reprint, copy or store the contents in electronic data processing systems without the express permission of the EMH. All trade marks and product names mentioned in this manual are the property of the EMH metering GmbH & Co. KG or the respective title holder. EMH is certified in accordance with DIN E ...
... reprint, copy or store the contents in electronic data processing systems without the express permission of the EMH. All trade marks and product names mentioned in this manual are the property of the EMH metering GmbH & Co. KG or the respective title holder. EMH is certified in accordance with DIN E ...
ISL59482 Datasheet
... Storage Temperature Range. . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C Ambient Operating Temperature . . . . . . . . . . . . . . . . . . . . . -40°C to +85°C Operating Junction Temperature . . . . . . . . . . . . . . . . . . . .-40°C to +125°C Power Dissipation. . . . . . . . . . . ...
... Storage Temperature Range. . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C Ambient Operating Temperature . . . . . . . . . . . . . . . . . . . . . -40°C to +85°C Operating Junction Temperature . . . . . . . . . . . . . . . . . . . .-40°C to +125°C Power Dissipation. . . . . . . . . . . ...
DN1021 - How to Produce Negative Output Voltages from Positive Inputs Using a uModule Step-Down Regulator
... regulators are complete switchmode power supplies in a surface-mount package. They include the DC/DC controller, inductor, power switches and supporting circuitry. These highly integrated regulators also provide an easy solution for applications that require negative output voltages. In other words, ...
... regulators are complete switchmode power supplies in a surface-mount package. They include the DC/DC controller, inductor, power switches and supporting circuitry. These highly integrated regulators also provide an easy solution for applications that require negative output voltages. In other words, ...
Monitoring of electrical equipment failure indicators and zero
... addition, the inherent ability of circuit breakers to interrupt repeated faults provided a sense of confidence in the electrical equipment. Other operating-mode recommendations involved the number of operations of electrical equipment. The number of operations is available on a mechanical counter an ...
... addition, the inherent ability of circuit breakers to interrupt repeated faults provided a sense of confidence in the electrical equipment. Other operating-mode recommendations involved the number of operations of electrical equipment. The number of operations is available on a mechanical counter an ...
DRV8801-Q1 DMOS Full-Bridge Motor Drivers
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
南台科技大學 電力電子研究室
... for insulated gate bipolar transistors (IGBTs), under open- and shortcircuit failures, are proposed. This tech- nique is applied to a threephase induction-motor (IM) drive system. The detection technique is adapted to detect failures of short-circuit and open-circuit in the IGBT, which is based on g ...
... for insulated gate bipolar transistors (IGBTs), under open- and shortcircuit failures, are proposed. This tech- nique is applied to a threephase induction-motor (IM) drive system. The detection technique is adapted to detect failures of short-circuit and open-circuit in the IGBT, which is based on g ...
BA324D - Sense
... allows the BA324D to be installed throughout the world. The 4/20mA input terminals comply with the requirements for simple apparatus enabling the indicator to be connected in series with most certified intrinsically safe circuits; together with the low voltage drop, this makes the instrument very ea ...
... allows the BA324D to be installed throughout the world. The 4/20mA input terminals comply with the requirements for simple apparatus enabling the indicator to be connected in series with most certified intrinsically safe circuits; together with the low voltage drop, this makes the instrument very ea ...
MPQ2451-5/33-AEC1 - Monolithic Power System
... pulse so the power MOSFET does not turn ON; this procedure reduces gate driving and switching losses. This PAUSE command causes the whole chip to enter sleep mode, reducing the quiescent current to further improve light-load efficiency. When VCOMP exceeds the sleep threshold, the PAUSE signal resets ...
... pulse so the power MOSFET does not turn ON; this procedure reduces gate driving and switching losses. This PAUSE command causes the whole chip to enter sleep mode, reducing the quiescent current to further improve light-load efficiency. When VCOMP exceeds the sleep threshold, the PAUSE signal resets ...
v. effect of different kinds of inter-turn winding faults on magnetic flux
... subsequently destructive failures [17]. Four kinds of internal faults in stator winding are stator turn-to-turn short circuit in the same branch, turn-to-turn short circuit of two branches in the same phase, turn-to-turn short circuit of two branches in different phases, and turn-to-earth fault are ...
... subsequently destructive failures [17]. Four kinds of internal faults in stator winding are stator turn-to-turn short circuit in the same branch, turn-to-turn short circuit of two branches in the same phase, turn-to-turn short circuit of two branches in different phases, and turn-to-earth fault are ...
BDTIC www.BDTIC.com/infineon Wireless Control Components ASK / FSK Single Conversion Receivers
... As can be seen from the block diagram in Figure 2-1, the basic concept of the TDA5210 is a single conversion receiver with an on-chip fully integrated PLL frequency synthesizer and an IF of nominally 10.7MHz. The 10.7MHz IF was selected because of the availability of low-cost ceramic filters in a va ...
... As can be seen from the block diagram in Figure 2-1, the basic concept of the TDA5210 is a single conversion receiver with an on-chip fully integrated PLL frequency synthesizer and an IF of nominally 10.7MHz. The 10.7MHz IF was selected because of the availability of low-cost ceramic filters in a va ...
2.2.2 Monostable Circuits Word Document
... The output pulse can be arranged to give either a logic 1 pulse or a logic 0 pulse depending on the application. Monostable circuits are useful for creating automatic delays in circuits, with a time that can be controlled by the circuit designer. Such a delay can be used for keeping an outside lamp ...
... The output pulse can be arranged to give either a logic 1 pulse or a logic 0 pulse depending on the application. Monostable circuits are useful for creating automatic delays in circuits, with a time that can be controlled by the circuit designer. Such a delay can be used for keeping an outside lamp ...
08 SFT2841 connected..
... Metering functions Phase-to-phase voltage This function gives the RMS value of the 50 or 60 Hz component of the phase-to-phase voltages. U21 voltage between phases 2 and 1 (U21=V1-V2) U32 voltage between phases 3 and 2 (U32=V2-V3) U13 voltage between phases 1 and 3 (U13=V3-V1) – by calculat ...
... Metering functions Phase-to-phase voltage This function gives the RMS value of the 50 or 60 Hz component of the phase-to-phase voltages. U21 voltage between phases 2 and 1 (U21=V1-V2) U32 voltage between phases 3 and 2 (U32=V2-V3) U13 voltage between phases 1 and 3 (U13=V3-V1) – by calculat ...
MAX793/MAX794/MAX795 3.0V/3.3V Adjustable Microprocessor Supervisory Circuits General Description
... Note 7: OUT switches from BATT to VCC when VCC rises above the reset threshold, if VBATT > VRST. In this case, switchover back to VCC occurs at the exact voltage that causes reset to be asserted, however, switchover occurs 200ms prior to reset. If VBATT < VRST, OUT switches from BATT to VCC when VCC ...
... Note 7: OUT switches from BATT to VCC when VCC rises above the reset threshold, if VBATT > VRST. In this case, switchover back to VCC occurs at the exact voltage that causes reset to be asserted, however, switchover occurs 200ms prior to reset. If VBATT < VRST, OUT switches from BATT to VCC when VCC ...
Study of Inductive-Capacitive Series Circuits Using
... simulate the electrical circuits and analyze different operating regimes. Because the signal step response or pulse generates a transitory regime, the circuit behavior in these conditions can be studied. The simulation is shown in Fig.27: The advantage of this simulation method is that the circuit c ...
... simulate the electrical circuits and analyze different operating regimes. Because the signal step response or pulse generates a transitory regime, the circuit behavior in these conditions can be studied. The simulation is shown in Fig.27: The advantage of this simulation method is that the circuit c ...
MLX80050/51/30/31
... The MLX8005x/3x consist of a low-drop voltage regulator 5V/3.3V/70mA combined with a Reset/Watchdog unit and a LIN bus transceiver. The LIN transceiver is suitable for LIN bus systems conform to LIN specification revision 2.x and SAE J2602. The watchdog times of the integrated window watchdog can be ...
... The MLX8005x/3x consist of a low-drop voltage regulator 5V/3.3V/70mA combined with a Reset/Watchdog unit and a LIN bus transceiver. The LIN transceiver is suitable for LIN bus systems conform to LIN specification revision 2.x and SAE J2602. The watchdog times of the integrated window watchdog can be ...
Agilent Network Analyzer Basics - Steven M. Anlage Research Page
... the ratio of the reflected signal voltage to the incident signal voltage. It can be calculated as shown above by knowing the impedances of the transmission line and the load. The magnitude portion of gamma is called rho (ρ). A transmission line terminated in Zo will have all energy transferred to th ...
... the ratio of the reflected signal voltage to the incident signal voltage. It can be calculated as shown above by knowing the impedances of the transmission line and the load. The magnitude portion of gamma is called rho (ρ). A transmission line terminated in Zo will have all energy transferred to th ...