DAC8580 数据资料 dataSheet 下载
... input data is latched into the device input shift register on the rising edge of SCLK, MSB first. The falling edge of FSYNC latches the last 16 bits of received data (right-justified) from the shift register into a temporary register, which connects to either the digital filter or the DAC latch. Dat ...
... input data is latched into the device input shift register on the rising edge of SCLK, MSB first. The falling edge of FSYNC latches the last 16 bits of received data (right-justified) from the shift register into a temporary register, which connects to either the digital filter or the DAC latch. Dat ...
ValuTrol Main Control Module (Full wave, Regenerative)
... Three-phase AC power enters the system through fuses and is fed into power conversion modules (SCR) where it is converted to adjustable voltage DC power for the DC motor armature. Two conversion modules may be used as in Figure 1 toprovidemotoringandregenerativecontrolofthe DC load in both forward a ...
... Three-phase AC power enters the system through fuses and is fed into power conversion modules (SCR) where it is converted to adjustable voltage DC power for the DC motor armature. Two conversion modules may be used as in Figure 1 toprovidemotoringandregenerativecontrolofthe DC load in both forward a ...
FMA4A
... The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from RO ...
... The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from RO ...
BD8967FVM
... 5. Consideration on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including l ...
... 5. Consideration on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including l ...
ADC08D500 High Performance, Low Power, Dual 8
... performance limits. For ensured specifications and test conditions, see the Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. When the input ...
... performance limits. For ensured specifications and test conditions, see the Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. When the input ...
DLL Considerations in QDRII/DDRII SRAMs
... Table 2 outlines the read latency of the different revisions of the QDRII device when the DLL is bypassed or disabled. Refer to the respective device data sheets for timings with DLL enabled. The output timings differ significantly between when the DLL is enabled and disabled. For instance, consider ...
... Table 2 outlines the read latency of the different revisions of the QDRII device when the DLL is bypassed or disabled. Refer to the respective device data sheets for timings with DLL enabled. The output timings differ significantly between when the DLL is enabled and disabled. For instance, consider ...
MAX3453E–MAX3456E ±15kV ESD-Protected USB Transceivers General Description Features
... The MAX3453E–MAX3456E USB-compliant transceivers convert single-ended or differential logic-level signals to USB signals, and USB signals to single-ended or differential logic-level signals. The MAX3453E fully complies with full-speed (12Mbps) operation under USB specification 2.0. The MAX3454E–MAX3 ...
... The MAX3453E–MAX3456E USB-compliant transceivers convert single-ended or differential logic-level signals to USB signals, and USB signals to single-ended or differential logic-level signals. The MAX3453E fully complies with full-speed (12Mbps) operation under USB specification 2.0. The MAX3454E–MAX3 ...
Bybee Music Rail
... unpredictable ways, causing distortion. The sound is then no longer pure and transparent. It is polluted by noise. In an audio amplifier, the stream of water is replaced by a stream of electrons. The electron stream originates in the power supply. There is no piano string, but the effect is the same ...
... unpredictable ways, causing distortion. The sound is then no longer pure and transparent. It is polluted by noise. In an audio amplifier, the stream of water is replaced by a stream of electrons. The electron stream originates in the power supply. There is no piano string, but the effect is the same ...
BY 240 / BY 840
... the feed forward signal must be proportional to the master speed. There are two ways to generate Vin: ...
... the feed forward signal must be proportional to the master speed. There are two ways to generate Vin: ...
9.6V, 1600mAh Ni-MH Battery Pack and Charger
... The obstacle avoidance system of ParkBot will be using either infrared waves or ultrasonic waves to project a beam of light or a pulse of sound out of the ultrasonic or infrared sensors. If the light or the pulse of sound is reflected back then the system can identify if there is an object in the pa ...
... The obstacle avoidance system of ParkBot will be using either infrared waves or ultrasonic waves to project a beam of light or a pulse of sound out of the ultrasonic or infrared sensors. If the light or the pulse of sound is reflected back then the system can identify if there is an object in the pa ...
Evaluates: MAX5926 MAX5926 Evaluation Kit General Description Features
... 0.3V/ms. Refer to the MAX5926 IC data sheet for more details on calculating C2 for a different slew rate. Short-circuit detection must be used on the MAX5926 EV kit when no RSENSE is used, and must not be used when an RSENSE is used. Table 7 shows the jumper JU7 settings to enable or disable short-c ...
... 0.3V/ms. Refer to the MAX5926 IC data sheet for more details on calculating C2 for a different slew rate. Short-circuit detection must be used on the MAX5926 EV kit when no RSENSE is used, and must not be used when an RSENSE is used. Table 7 shows the jumper JU7 settings to enable or disable short-c ...
TPA3002D2 数据资料 dataSheet 下载
... applied to the volume control terminal offering a range of gain from –40 dB to 36 dB. Line outputs, for driving external headphone amplifier inputs, are also dc voltage controlled with a range of gain from –56 dB to 20 dB. An integrated 5-V regulated supply is provided for ...
... applied to the volume control terminal offering a range of gain from –40 dB to 36 dB. Line outputs, for driving external headphone amplifier inputs, are also dc voltage controlled with a range of gain from –56 dB to 20 dB. An integrated 5-V regulated supply is provided for ...
Switch-on-to-Fault Schemes in the Context of Line Relay Loadability
... Reclosing logic for the ‘follower’ terminal may include (in addition to a sync-check element) both live-bus and live-line voltage detectors set at or above the lowest system voltage for which automatic reclosing is deemed desirable. A setting in the vicinity of 0.8 PER UNIT is not unusual. If pre-cl ...
... Reclosing logic for the ‘follower’ terminal may include (in addition to a sync-check element) both live-bus and live-line voltage detectors set at or above the lowest system voltage for which automatic reclosing is deemed desirable. A setting in the vicinity of 0.8 PER UNIT is not unusual. If pre-cl ...
User’s Manual 543-0032-00, 943-0032-00 1
... To verify the installation of Comfort Alert is correct, two functional tests can be performed. Disconnect power from the compressor and force a thermostat call for cooling. The red Trip LED should turn on indicating a compressor trip as long as 24VAC is measured at the Y terminal. If the red LED doe ...
... To verify the installation of Comfort Alert is correct, two functional tests can be performed. Disconnect power from the compressor and force a thermostat call for cooling. The red Trip LED should turn on indicating a compressor trip as long as 24VAC is measured at the Y terminal. If the red LED doe ...
Hotswap Design Using TPS2490/01 and MOSFET Transient
... A successful design meets the system specifications while keeping the junction temperature of the limiting MOSFET below the manufacturer’s absolute-maximum rating. The introduction of the TPS2490/91, a hotswap controller with constant-power limiting, greatly simplifies the design of hotswap circuits ...
... A successful design meets the system specifications while keeping the junction temperature of the limiting MOSFET below the manufacturer’s absolute-maximum rating. The introduction of the TPS2490/91, a hotswap controller with constant-power limiting, greatly simplifies the design of hotswap circuits ...
section 260913 - electrical power monitoring
... Hardwired Monitoring Points: Electrical power demand (kilowatts), electrical power consumption (kilowatt-hours)[, power factor].
...
... Hardwired Monitoring Points: Electrical power demand (kilowatts), electrical power consumption (kilowatt-hours)[, power factor]
AD830: High Speed, Video Difference Amplifier Data Sheet (Rev B, 01/2003)
... The topology, reduced to its elemental form, is shown in Figure 7. Nonideal effects, such as nonlinearity, bias currents, and limited full scale, are omitted from this model for simplicity, but are discussed later. The key feature of this topology is the use of two, identical voltage-to-current conv ...
... The topology, reduced to its elemental form, is shown in Figure 7. Nonideal effects, such as nonlinearity, bias currents, and limited full scale, are omitted from this model for simplicity, but are discussed later. The key feature of this topology is the use of two, identical voltage-to-current conv ...
BUF602 数据资料 dataSheet 下载
... This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete devi ...
... This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete devi ...
Tiny 1.5A boost converter with adjustable input current limit (Rev. A)
... application, the frequency is 3.25 MHz and is defined by the input to output voltage ratio and does not vary from moderate to heavy load currents. At light load currents, the converter automatically enters Power Save Mode and operates in PFM (Pulse Frequency Modulation) mode. During pulse-width-modu ...
... application, the frequency is 3.25 MHz and is defined by the input to output voltage ratio and does not vary from moderate to heavy load currents. At light load currents, the converter automatically enters Power Save Mode and operates in PFM (Pulse Frequency Modulation) mode. During pulse-width-modu ...
analog -digital multimeter user`s manual
... a sound signal. The symbols DC and AC (21)are displayed as per selected function on the LCD. When selecting a range with the function selector switch (6), the DC function is always set by default. Connect the multimeter in series with the load, as shown. Ensure that the connections are tight (with l ...
... a sound signal. The symbols DC and AC (21)are displayed as per selected function on the LCD. When selecting a range with the function selector switch (6), the DC function is always set by default. Connect the multimeter in series with the load, as shown. Ensure that the connections are tight (with l ...