AAT3681A 数据资料DataSheet下载
... The AAT3681A is a high performance battery charger designed for single cell lithium-ion/polymer batteries with up to 500mA of charge current from an external power source. It is a stand-alone charging solution, with just one external component required for complete functionality. The AAT3681A precis ...
... The AAT3681A is a high performance battery charger designed for single cell lithium-ion/polymer batteries with up to 500mA of charge current from an external power source. It is a stand-alone charging solution, with just one external component required for complete functionality. The AAT3681A precis ...
PSC18
... Input filter suppressing the feedback of high frequency interference produced by the unit into the mains as well as for the attenuation of the interference voltages and voltage transients superimposed on the mains. Rectifier (polar protection) with synchronised power controller (operating frequency ...
... Input filter suppressing the feedback of high frequency interference produced by the unit into the mains as well as for the attenuation of the interference voltages and voltage transients superimposed on the mains. Rectifier (polar protection) with synchronised power controller (operating frequency ...
IMS2 User Manual
... Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and understand all instructions in this manual prior to installing, operating or maintaining the starter, to follow good electrical practi ...
... Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and understand all instructions in this manual prior to installing, operating or maintaining the starter, to follow good electrical practi ...
FG2206 Construction Manual
... Bold face parameters are covered by production test and guaranteed over operating temperature range. ...
... Bold face parameters are covered by production test and guaranteed over operating temperature range. ...
Micronta 22-204A range doubler multimeter instructions
... You can probably completely ignore the dB scale, most people will never need it. 1. Plug the test leads into the correct jacks (Black into COM and Red into +V.ohms.A). 2. Set the Range and Voltage Doubler switches as required to obtain a meter reading in the upper half of the scale. 3. Read dB on th ...
... You can probably completely ignore the dB scale, most people will never need it. 1. Plug the test leads into the correct jacks (Black into COM and Red into +V.ohms.A). 2. Set the Range and Voltage Doubler switches as required to obtain a meter reading in the upper half of the scale. 3. Read dB on th ...
LTC1664 - Micropower Quad 10-Bit DAC
... –0.3V ≤ VREF ≤ VCC + 0.3V (see Absolute Maximum Ratings). Particular care should be taken to observe these limits during power supply turn-on and turn-off sequences, when the voltage at VCC (Pin 16) is in transition. If it is not possible to sequence the supplies, connect a Schottky diode from REF ( ...
... –0.3V ≤ VREF ≤ VCC + 0.3V (see Absolute Maximum Ratings). Particular care should be taken to observe these limits during power supply turn-on and turn-off sequences, when the voltage at VCC (Pin 16) is in transition. If it is not possible to sequence the supplies, connect a Schottky diode from REF ( ...
LVDS Signaling Using APEX Device I/O Pins Introduction
... a VREF pin, check the box that enables the feature Reserve Pin (even if it does not exist in the design file) and select As VREF from the drop down list associated with the reserve pin field. ...
... a VREF pin, check the box that enables the feature Reserve Pin (even if it does not exist in the design file) and select As VREF from the drop down list associated with the reserve pin field. ...
Dual, 256-Tap, Volatile, Low-Voltage, Linear Taper Digital Potentiometer MAX5392 General Description Features
... The MAX5392 dual, 256-tap, volatile, low-voltage linear taper digital potentiometer offers three end-to-end resistance values of 10kI, 50kI, and 100kI. The potentiometer consists of 255 fixed resistors in series between terminals H_ and L_. The potentiometer wiper, W_, is programmable to access any ...
... The MAX5392 dual, 256-tap, volatile, low-voltage linear taper digital potentiometer offers three end-to-end resistance values of 10kI, 50kI, and 100kI. The potentiometer consists of 255 fixed resistors in series between terminals H_ and L_. The potentiometer wiper, W_, is programmable to access any ...
a Precision, Wide Bandwidth 3-Port Isolation Amplifier AD210*
... greater. The adjustment becomes less effective at lower gains (its effect is halved at G = 2) so that the pot will have to be a larger fraction of the total RF at low gain. At G = 1 (follower) the gain cannot be adjusted downward without compromising input impedance; it is better to adjust gain at t ...
... greater. The adjustment becomes less effective at lower gains (its effect is halved at G = 2) so that the pot will have to be a larger fraction of the total RF at low gain. At G = 1 (follower) the gain cannot be adjusted downward without compromising input impedance; it is better to adjust gain at t ...
Ramp/Soak Process Controller E5CK-T
... Signals available as allocated outputs are the control output (heat), control output (cool), alarm 1, alarm 2, alarm 3, LBA. The auxiliary outputs of the Process Controller cannot be used as control outputs. The E5CK-T does not have a heater burnout alarm (HBA). Control output (heat), control output ...
... Signals available as allocated outputs are the control output (heat), control output (cool), alarm 1, alarm 2, alarm 3, LBA. The auxiliary outputs of the Process Controller cannot be used as control outputs. The E5CK-T does not have a heater burnout alarm (HBA). Control output (heat), control output ...
LTC6104 - High Voltage, High Side, Bi-Directional Current Sense Amplifier
... The LTC®6104 is a versatile, high voltage, high side, bidirectional current sense amplifier. Design flexibility is provided by the excellent device characteristics: ±450µV maximum offset and only 520µA of current consumption (typical at 12V). The LTC6104 operates on supplies from 4V to 60V. The LTC610 ...
... The LTC®6104 is a versatile, high voltage, high side, bidirectional current sense amplifier. Design flexibility is provided by the excellent device characteristics: ±450µV maximum offset and only 520µA of current consumption (typical at 12V). The LTC6104 operates on supplies from 4V to 60V. The LTC610 ...
High PSR Low Drop-out Voltage Regulator (LDO)
... and ro−pass are the transconductance and output resistance respectively of pass element and β is the result of voltage divider feedback network. As discussed previously in section II-B the performance of the error amplifier is directly correlated with the PSSR of the LDO system. The intuitive mode a ...
... and ro−pass are the transconductance and output resistance respectively of pass element and β is the result of voltage divider feedback network. As discussed previously in section II-B the performance of the error amplifier is directly correlated with the PSSR of the LDO system. The intuitive mode a ...
Precision, Wide Bandwidth 3-Port Isolation Amplifier AD210*
... 20 kHz makes it useful for wideband signals. It is also effective in applications like control loops, where limited bandwidth could result in instability. Small Size: The AD210 provides a complete isolation function in a small DIP package just 1.00" × 2.10" × 0.350". The low profile DIP package allo ...
... 20 kHz makes it useful for wideband signals. It is also effective in applications like control loops, where limited bandwidth could result in instability. Small Size: The AD210 provides a complete isolation function in a small DIP package just 1.00" × 2.10" × 0.350". The low profile DIP package allo ...
AudioFire Windows Manual
... 7. Power Sources - This unit should be operated only from the type of power source indicated in this documentation or on your Echo product. If you are unsure about the type of power at your location, contact your local power company. 8. Grounding – Precautions should be taken so that the grounding c ...
... 7. Power Sources - This unit should be operated only from the type of power source indicated in this documentation or on your Echo product. If you are unsure about the type of power at your location, contact your local power company. 8. Grounding – Precautions should be taken so that the grounding c ...
ICS850S1601I Advance Data Sheet.fm
... NOTE 2: Defined as skew between outputs on different devices operating at the same supply voltage and with equal load conditions. Using the same type of inputs on each device, the outputs are measured at the differential cross points. NOTE 3: This parameter is defined according with JEDEC Standard 6 ...
... NOTE 2: Defined as skew between outputs on different devices operating at the same supply voltage and with equal load conditions. Using the same type of inputs on each device, the outputs are measured at the differential cross points. NOTE 3: This parameter is defined according with JEDEC Standard 6 ...