SEL-734 Quick
... The File > Send command sends any changes made within ACSELERATOR QuickSet to the meter. ACSELERATOR QuickSet automatically selects modified configuration settings groups and warns if these settings will overwrite existing data or change active communications parameters. Figure 11 ...
... The File > Send command sends any changes made within ACSELERATOR QuickSet to the meter. ACSELERATOR QuickSet automatically selects modified configuration settings groups and warns if these settings will overwrite existing data or change active communications parameters. Figure 11 ...
Using the ECC HTML Pages
... When line voltages on a polyphase, squirrel-cage induction motor are not equal, the corresponding unbalanced currents cause excessive heating of the stator winding. The percentage of voltage unbalance corresponds to a proportionally larger percentage of current unbalance. Consequently, the temperatu ...
... When line voltages on a polyphase, squirrel-cage induction motor are not equal, the corresponding unbalanced currents cause excessive heating of the stator winding. The percentage of voltage unbalance corresponds to a proportionally larger percentage of current unbalance. Consequently, the temperatu ...
Chapter 2
... “adjust” its impedance based on varying input voltages and loads (RL) to be able to maintain its designated zener voltage. Zener current will increase or decrease directly with voltage input changes. The zener current will increase or decrease inversely with varying loads. Again, the zener has a ...
... “adjust” its impedance based on varying input voltages and loads (RL) to be able to maintain its designated zener voltage. Zener current will increase or decrease directly with voltage input changes. The zener current will increase or decrease inversely with varying loads. Again, the zener has a ...
radius log- basic / pro / pro plus
... Installation and commissioning must be carried out by an installation technician. The personnel must have access to the Operating Instructions at all times. The personnel responsible for installation, operation and maintenance must have read and understood these Operating Instructions. Gefran spaacc ...
... Installation and commissioning must be carried out by an installation technician. The personnel must have access to the Operating Instructions at all times. The personnel responsible for installation, operation and maintenance must have read and understood these Operating Instructions. Gefran spaacc ...
This article appeared in a journal published by Elsevier. The... copy is furnished to the author for internal non-commercial research
... To draw states that cannot be measured directly, such as the SOC and parameters of a battery, will be even more difficult. The ampere-hour counting (Coulomb counting, or current integration) method for the calculation of battery SOC is simple and easy to implement, but the method needs the prior know ...
... To draw states that cannot be measured directly, such as the SOC and parameters of a battery, will be even more difficult. The ampere-hour counting (Coulomb counting, or current integration) method for the calculation of battery SOC is simple and easy to implement, but the method needs the prior know ...
VWR® Mini Gel
... 1. Make sure the power supply is turned off 2. Plug the male ends of the black (-) and red (+) electrodes into the jacks on the side of the power supply. 3. After the samples have been loaded into the gel, place the lid over the unit so that the lid covers align with the tank. Set the lid straight d ...
... 1. Make sure the power supply is turned off 2. Plug the male ends of the black (-) and red (+) electrodes into the jacks on the side of the power supply. 3. After the samples have been loaded into the gel, place the lid over the unit so that the lid covers align with the tank. Set the lid straight d ...
UBA20271/2 350 V and 600 V Power ICs for dimmable compact
... supply (VDD) reaches the value of VDD(start) AND Vi(DCI) > Vth(start)DCI. The circuit starts oscillating at fbridge(max). The circuit enters the preheat state as soon as the capacitor on the CP pin is charged to a voltage level higher than Vth(CP)max. To remain oscillating, the VDD voltage must rema ...
... supply (VDD) reaches the value of VDD(start) AND Vi(DCI) > Vth(start)DCI. The circuit starts oscillating at fbridge(max). The circuit enters the preheat state as soon as the capacitor on the CP pin is charged to a voltage level higher than Vth(CP)max. To remain oscillating, the VDD voltage must rema ...
MAX9394/MAX9395 2:1 Multiplexers and 1:2 Demultiplexers with Loopback General Description
... signaling (LVDS) inputs and generates a single LVDS output. The demultiplexer section (channel A) accepts a single LVDS input and generates two parallel LVDS outputs. The MAX9394/MAX9395 feature a loopback mode that connects the input of channel A to the output of channel B and connects the selected ...
... signaling (LVDS) inputs and generates a single LVDS output. The demultiplexer section (channel A) accepts a single LVDS input and generates two parallel LVDS outputs. The MAX9394/MAX9395 feature a loopback mode that connects the input of channel A to the output of channel B and connects the selected ...
Transients in Power Systems - Purdue e-Pubs
... This paper provides an introduction to wavelets and their application for power systems transients. Since wavelets are a relatively new development in engineering, a brief history will be presented for the sake of the uninitiated. An overview of the Integral Wavelet Transform, the Discrete Wavelet T ...
... This paper provides an introduction to wavelets and their application for power systems transients. Since wavelets are a relatively new development in engineering, a brief history will be presented for the sake of the uninitiated. An overview of the Integral Wavelet Transform, the Discrete Wavelet T ...
Chapter 4 Circuit Theorems
... We can get I1 2 A, V2 2V ; When R2 4, V1 10V , We can get I1 3 A, find out V2 then. ...
... We can get I1 2 A, V2 2V ; When R2 4, V1 10V , We can get I1 3 A, find out V2 then. ...
Application Note 74 LM139/LM239/LM339 A Quad
... The LM139 can be used to symmetrically square up a sine wave centered around zero volts by incorporating a small amount of positive feedback to improve switching times and centering the input threshold at ground (see Figure 10). Voltage divider R4 and R5 establishes a reference voltage, V1, at the p ...
... The LM139 can be used to symmetrically square up a sine wave centered around zero volts by incorporating a small amount of positive feedback to improve switching times and centering the input threshold at ground (see Figure 10). Voltage divider R4 and R5 establishes a reference voltage, V1, at the p ...
Technical Note - Copley Controls
... In a transient condition, the motor can tolerate a certain amount of energy in excess of the continuous limit. The amount of overload energy the motor can handle is dependent on the motor size, cooling methods and configuration. For a given motor with winding resistance RL the energy dissipated in e ...
... In a transient condition, the motor can tolerate a certain amount of energy in excess of the continuous limit. The amount of overload energy the motor can handle is dependent on the motor size, cooling methods and configuration. For a given motor with winding resistance RL the energy dissipated in e ...
AND8256/D Control of the Output Voltage Range in NCP1653
... Some validation tests have been made on a 300 W demo board. They confirm the here above analysis. The output regulation was measured over the line range (from 90 to 260 V) and at three different load currents (0.11 A, 0.40 A and 0.70 A that corresponds to the full load): • First with RCS2 = 48 kW th ...
... Some validation tests have been made on a 300 W demo board. They confirm the here above analysis. The output regulation was measured over the line range (from 90 to 260 V) and at three different load currents (0.11 A, 0.40 A and 0.70 A that corresponds to the full load): • First with RCS2 = 48 kW th ...