CAB 4N Manual - Peavey Commercial Audio
... selected, then it will take +18 dBu of level to get to a 0 dB reading (full-scale A/D) on the front panel input meter. The setting in the Full-Scale Input Sensitivity dialog box will determine how the front panel input meters display audio levels coming into the CAB 4n. It is very important that the ...
... selected, then it will take +18 dBu of level to get to a 0 dB reading (full-scale A/D) on the front panel input meter. The setting in the Full-Scale Input Sensitivity dialog box will determine how the front panel input meters display audio levels coming into the CAB 4n. It is very important that the ...
ADG1221 数据手册DataSheet下载
... of these switches make them ideal solutions for data acquisition and sample-and-hold applications, where low glitch and fast settling are required. Figure 2 shows that there is minimum charge injection over the full signal range of the device. ...
... of these switches make them ideal solutions for data acquisition and sample-and-hold applications, where low glitch and fast settling are required. Figure 2 shows that there is minimum charge injection over the full signal range of the device. ...
+5V-Powered, Multichannel RS-232 Drivers/Receivers General Description Next-Generation Device Features
... Note 1: For the MAX220, V+ and V- can have a maximum magnitude of 7V, but their absolute difference cannot exceed 13V. Note 2: Input voltage measured with TOUT in high-impedance state, VSHDN or VCC = 0V. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the ...
... Note 1: For the MAX220, V+ and V- can have a maximum magnitude of 7V, but their absolute difference cannot exceed 13V. Note 2: Input voltage measured with TOUT in high-impedance state, VSHDN or VCC = 0V. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the ...
LTC3827-1 - Low IQ, Dual, 2-Phase
... RUN1, RUN2 (Pins 8, 9): Digital Run Control Inputs for Each Controller. Forcing either of these pins below 0.7V shuts down that controller. Forcing both of these pins below 0.7V shuts down the entire LTC3827-1, reducing quiescent current to approximately 8μA. ...
... RUN1, RUN2 (Pins 8, 9): Digital Run Control Inputs for Each Controller. Forcing either of these pins below 0.7V shuts down that controller. Forcing both of these pins below 0.7V shuts down the entire LTC3827-1, reducing quiescent current to approximately 8μA. ...
Earth Fault Currents in Three Phase systems
... can be the cause of earth faults. Once tracking takes place, any surrounding air will ionize which will then behave like a solid conductor consequently creating a “solid” fault. Passive faults can be considered more as conditions rather than real faults. They are more of conditions that are stressin ...
... can be the cause of earth faults. Once tracking takes place, any surrounding air will ionize which will then behave like a solid conductor consequently creating a “solid” fault. Passive faults can be considered more as conditions rather than real faults. They are more of conditions that are stressin ...
MAX13410E–MAX13415E RS-485 Transceiver with Integrated Low-Dropout Regulator and AutoDirection Control General Description
... MAX13414E/MAX13415E only), guaranteeing a logichigh receiver output when the receiver inputs are open or shorted. The receiver outputs a logic-high when the transmitter on the terminated bus is disabled (high impedance). The MAX13412E/MAX13413E feature Maxim’s proprietary AutoDirection control. This ...
... MAX13414E/MAX13415E only), guaranteeing a logichigh receiver output when the receiver inputs are open or shorted. The receiver outputs a logic-high when the transmitter on the terminated bus is disabled (high impedance). The MAX13412E/MAX13413E feature Maxim’s proprietary AutoDirection control. This ...
bq27532-G1 Technical Reference Manual
... 6.2.10 Avg I Last Run .................................................................................................... 6.2.11 Avg P Last Run ................................................................................................... 6.2.12 Delta Voltage .................................. ...
... 6.2.10 Avg I Last Run .................................................................................................... 6.2.11 Avg P Last Run ................................................................................................... 6.2.12 Delta Voltage .................................. ...
Crompton Instruments Integra and Paladin Transducers
... current, frequency, Watts, VAr, VA, energy, power factor and total harmonic distortion measurement of both phase and system, current and voltage. A simple Windows based software package is provided to configure the transducer. Once configured, up to 50 electrical and power quality variables can be s ...
... current, frequency, Watts, VAr, VA, energy, power factor and total harmonic distortion measurement of both phase and system, current and voltage. A simple Windows based software package is provided to configure the transducer. Once configured, up to 50 electrical and power quality variables can be s ...
Manual
... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...
... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...
IM483 High Performance Microstepping Drive
... a Bookmark feature that allows the reader to link from a Bookmarked Topic in the Table of Contents to a full description of that feature’s attributes and functions. You can also select a Topic directly from the Table of Contents Pages. Topics with a Bookmark function are further identifiable because ...
... a Bookmark feature that allows the reader to link from a Bookmarked Topic in the Table of Contents to a full description of that feature’s attributes and functions. You can also select a Topic directly from the Table of Contents Pages. Topics with a Bookmark function are further identifiable because ...
UltraVolt, Inc. - Application Notes for High Voltage Power Supplies
... signal disables the output. If pin 4 is left open, the power supply defaults to an enabled state. The data sheet has detailed information on logic levels. Pin 5 – Signal Ground Return: The signal ground should be used as the reference point for both the remote adjust and the monitors. Do not return ...
... signal disables the output. If pin 4 is left open, the power supply defaults to an enabled state. The data sheet has detailed information on logic levels. Pin 5 – Signal Ground Return: The signal ground should be used as the reference point for both the remote adjust and the monitors. Do not return ...
ib0600367engd
... These manuals are required if you are going to utilize functions and performance. ...
... These manuals are required if you are going to utilize functions and performance. ...
Si7034-A10 - Silicon Labs
... low-K dielectrics as a sensor enables the Si7034 to achieve excellent long term stability and immunity to contaminants with low drift and hysteresis. The Si7034 offers a low power, high accuracy, calibrated and stable solution ideal for a wide range of temperature, humidity, and dew-point applicatio ...
... low-K dielectrics as a sensor enables the Si7034 to achieve excellent long term stability and immunity to contaminants with low drift and hysteresis. The Si7034 offers a low power, high accuracy, calibrated and stable solution ideal for a wide range of temperature, humidity, and dew-point applicatio ...
Lecture 2: Transfer Functions - University of California, Berkeley
... To directly calculate the transfer function (impedance, transimpedance, etc) we can generalize the circuit analysis concept from the “real” domain to the “phasor” domain With the concept of impedance (admittance), we can now directly analyze a circuit without explicitly writing down any differential ...
... To directly calculate the transfer function (impedance, transimpedance, etc) we can generalize the circuit analysis concept from the “real” domain to the “phasor” domain With the concept of impedance (admittance), we can now directly analyze a circuit without explicitly writing down any differential ...
Measurement of Scintillation and Ionization Yield and Scintillation
... signals produced by nuclear recoils between 10.3 and 57.3 keV in a liquid argon time projection chamber (LAr-TPC) with and without an applied electric field. The results described in this paper are relevant for the calibration and interpretation of data of LAr-TPC dark matter detectors [1–3]. They a ...
... signals produced by nuclear recoils between 10.3 and 57.3 keV in a liquid argon time projection chamber (LAr-TPC) with and without an applied electric field. The results described in this paper are relevant for the calibration and interpretation of data of LAr-TPC dark matter detectors [1–3]. They a ...
AT 121 - Chapter 2 - Basic Electrical Principals
... On Car Starter Motor Inspection – Customer Complaint – “Poor Crank, or Intermittent Crank” If a starter does not run, and the battery checks out, this simple test may be preformed on any vehicle. The test is broken down to inspect the most basic parts of a starter circuit. Proper power and ground ...
... On Car Starter Motor Inspection – Customer Complaint – “Poor Crank, or Intermittent Crank” If a starter does not run, and the battery checks out, this simple test may be preformed on any vehicle. The test is broken down to inspect the most basic parts of a starter circuit. Proper power and ground ...
Circuit Breaker Selection
... Quick interruption of short-circuit current is usually considered the primary function of a circuit breaker. The fault-current interrupting capability of Power/Vac circuit breakers is stated in threephase, symmetrical, rms AC amperes. Accordingly, calculation of the maximum available fault duty of a ...
... Quick interruption of short-circuit current is usually considered the primary function of a circuit breaker. The fault-current interrupting capability of Power/Vac circuit breakers is stated in threephase, symmetrical, rms AC amperes. Accordingly, calculation of the maximum available fault duty of a ...
powercut-1250 / 1500
... - Install and earth (ground) the welding or plasma cutting unit in accordance with applicable standards. - Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing. - Insulate yourself from earth and the workpiece. - Ensure your working stance is safe. FUME ...
... - Install and earth (ground) the welding or plasma cutting unit in accordance with applicable standards. - Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing. - Insulate yourself from earth and the workpiece. - Ensure your working stance is safe. FUME ...
Manual (Units installed prior to Nov 2006)
... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...
... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...