HDE Short Form Product Catalog
... innovation in the areas of controlling, testing, measuring and recording of electric power has resulted in the development of leading edge products designed to help you provide electric power to your customers safely and efficiently. Please take a moment to review this Short Form Product Catalog wit ...
... innovation in the areas of controlling, testing, measuring and recording of electric power has resulted in the development of leading edge products designed to help you provide electric power to your customers safely and efficiently. Please take a moment to review this Short Form Product Catalog wit ...
CD4069, CD4069-SMD Inverter Circuits
... wide power supply operating range, low power consumption, high noise immunity, and symmetric controlled rise and fall times. ...
... wide power supply operating range, low power consumption, high noise immunity, and symmetric controlled rise and fall times. ...
M1601_Intersection_Traffic_Light_PDA_Manual
... and allows the UPS to be a detachable unit that may be added or removed from the panel at any time, without interruption of service to the traffic cabinet (when optional ATS installed). The panel is intended to be a power distribution panel with an optional main service entrance, along with more ref ...
... and allows the UPS to be a detachable unit that may be added or removed from the panel at any time, without interruption of service to the traffic cabinet (when optional ATS installed). The panel is intended to be a power distribution panel with an optional main service entrance, along with more ref ...
Hardware Integration Application Notes
... We recommend that the user first do a qualitative application review of requirements. Following this, there are several sets of quantitative or Yes/No questions to be answered. Once the user fills out the checklist, a review between the user and their FAE can address the details and implications/tra ...
... We recommend that the user first do a qualitative application review of requirements. Following this, there are several sets of quantitative or Yes/No questions to be answered. Once the user fills out the checklist, a review between the user and their FAE can address the details and implications/tra ...
ADG3304 - Analog Devices
... The ADG3304 is a bidirectional logic level translator that contains four bidirectional channels. It can be used in multivoltage digital system applications, such as data transfer, between a low voltage digital signal processing controller and a higher voltage device using SPI and MICROWIRE interface ...
... The ADG3304 is a bidirectional logic level translator that contains four bidirectional channels. It can be used in multivoltage digital system applications, such as data transfer, between a low voltage digital signal processing controller and a higher voltage device using SPI and MICROWIRE interface ...
Lecture 15
... Ex: 2 kword x 16 folded into 256 rows x 128 columns – Must select 16 output bits from the 128 columns – Requires 16 8:1 column multiplexers ...
... Ex: 2 kword x 16 folded into 256 rows x 128 columns – Must select 16 output bits from the 128 columns – Requires 16 8:1 column multiplexers ...
Circuit Breakers - Single Pole Interrupting Capability
... An overcurrent protective device must have an interrupting rating equal to or greater than the fault current available at its line terminals for both three-phase bolted faults and for one or more phase-to-ground faults (110.9). Although most electrical systems are designed with overcurrent devices h ...
... An overcurrent protective device must have an interrupting rating equal to or greater than the fault current available at its line terminals for both three-phase bolted faults and for one or more phase-to-ground faults (110.9). Although most electrical systems are designed with overcurrent devices h ...
AN2299
... meters by calibration of voltage and current channels rather than of output pulse signal frequency. Since any energy measure performed by the device (active wide band and active fundamental, reactive or apparent) is calculated digitally (without error) from current and voltage calibrated signals, it ...
... meters by calibration of voltage and current channels rather than of output pulse signal frequency. Since any energy measure performed by the device (active wide band and active fundamental, reactive or apparent) is calculated digitally (without error) from current and voltage calibrated signals, it ...
TPS54560 - Texas Instruments
... start up ramp is internally controlled to provide a controlled start up and eliminate overshoot. A wide switching frequency range allows either efficiency or external component size to be optimized. Output current is limited cycle-by-cycle. Frequency foldback and thermal shutdown protects internal a ...
... start up ramp is internally controlled to provide a controlled start up and eliminate overshoot. A wide switching frequency range allows either efficiency or external component size to be optimized. Output current is limited cycle-by-cycle. Frequency foldback and thermal shutdown protects internal a ...
WCL488 Series 402828 Rev B1
... NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when equipment is operated in a commercial environment. This equipment ...
... NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when equipment is operated in a commercial environment. This equipment ...
eConnect MasterFormat Specs
... The PDU shall include two serial PDU Linking ports that allow multiple PDUs to be connected in a continuous chain of up to 32 PDUs for IP consolidation. All linked PDUs shall be remotely accessable though a single, primary Ethernet connection on one of the linked PDUs using either a third-party soft ...
... The PDU shall include two serial PDU Linking ports that allow multiple PDUs to be connected in a continuous chain of up to 32 PDUs for IP consolidation. All linked PDUs shall be remotely accessable though a single, primary Ethernet connection on one of the linked PDUs using either a third-party soft ...
NVT2001, NVT2002 - NXP Semiconductors
... total capacitance and the pull-up resistors on both sides combine to the parallel equivalent resistance. The Ron of the device is small compared to the pull-up resistor values, so its effect on the pull-up resistance can be neglected and the fall is determined by the driver pulling the combined capa ...
... total capacitance and the pull-up resistors on both sides combine to the parallel equivalent resistance. The Ron of the device is small compared to the pull-up resistor values, so its effect on the pull-up resistance can be neglected and the fall is determined by the driver pulling the combined capa ...
AN-873: Lock Detect on the ADF4xxx Family of
... (>15 MHz). This is because the period of the PFD frequency begins to approach the 15 ns window used to check for lock. For example, a 25 MHz PFD frequency has a period of 40 ns. In such a case, the accuracy of digital lock detect is compromised. In an unlocked state, if the unlocked frequency is clo ...
... (>15 MHz). This is because the period of the PFD frequency begins to approach the 15 ns window used to check for lock. For example, a 25 MHz PFD frequency has a period of 40 ns. In such a case, the accuracy of digital lock detect is compromised. In an unlocked state, if the unlocked frequency is clo ...
1 General - Eskom Board
... c. An alternative source of this abnormal condition is when power swings occur after a severe disturbance on the network. d. The supply voltage amplitude oscillates at a frequency between 0,2 and 2 Hz. e. In this case the voltage can fall as low as 65% of nominal and can rise up to 110% of nominal d ...
... c. An alternative source of this abnormal condition is when power swings occur after a severe disturbance on the network. d. The supply voltage amplitude oscillates at a frequency between 0,2 and 2 Hz. e. In this case the voltage can fall as low as 65% of nominal and can rise up to 110% of nominal d ...
AN-873 APPLICATION NOTE
... (>15 MHz). This is because the period of the PFD frequency begins to approach the 15 ns window used to check for lock. For example, a 25 MHz PFD frequency has a period of 40 ns. In such a case, the accuracy of digital lock detect is compromised. In an unlocked state, if the unlocked frequency is clo ...
... (>15 MHz). This is because the period of the PFD frequency begins to approach the 15 ns window used to check for lock. For example, a 25 MHz PFD frequency has a period of 40 ns. In such a case, the accuracy of digital lock detect is compromised. In an unlocked state, if the unlocked frequency is clo ...
A Single-Slope 80 MS/s ADC Using Two-Step Time to
... current source. Fig. 3 shows a simplified circuit diagram of the voltage-to-time converter which achieves a high output resistance current source through double cascoding. The drawback of having two cascode devices is limited voltage swing at the output of the current source. However, high output re ...
... current source. Fig. 3 shows a simplified circuit diagram of the voltage-to-time converter which achieves a high output resistance current source through double cascoding. The drawback of having two cascode devices is limited voltage swing at the output of the current source. However, high output re ...
Hello and welcome to this presentation
... • Hardware configuration and software configuration • An example use case • And a few frequently asked questions ...
... • Hardware configuration and software configuration • An example use case • And a few frequently asked questions ...