• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Ultracapacitor Based Ride Through System for Anand Vivek Ravi Vinod John
Ultracapacitor Based Ride Through System for Anand Vivek Ravi Vinod John

ACA-20PC Series - Murata Power Solutions
ACA-20PC Series - Murata Power Solutions

... (0-20A range) ac-powered models when their built-in auxiliary terminal block connections on TB1 are used to supply power to an external load. The input supply wires connected to both the ammeter and the load must be fused according to the current rating of the wire gauge being used, in accordance wi ...
2300_QU2_All_Sects_Spring2003
2300_QU2_All_Sects_Spring2003

... b) For this circuit, find the power absorbed by the current source. Remember to use lower-case variables for voltage, current, and power. ...
AND8129/DA 30 W Power Supply Operating in
AND8129/DA 30 W Power Supply Operating in

... turns a MOSFET ON until its current grows−up to the setpoint to turn it off and then waits until the core reset is detected (usually via an auxiliary winding) to reactivate this transistor. As a result, the controller does not include any standalone clock but only detects the presence of events cond ...
vector control and dual-threshold voltage techniques can not help
vector control and dual-threshold voltage techniques can not help

Philosophy of Topology and Components Selection for
Philosophy of Topology and Components Selection for

... of the transformer, decreases price, and increases the transformer’s efficiency. The rectifier works with ZCS commutation and without an inductor and with a duty cycle of 90%. When we have an output current of 100A and more, the output rectifier with an inductive filter is not a good solution becaus ...
05-Three Phase Analysis
05-Three Phase Analysis

... • We are concerned with balanced 3-phase • Balanced circuit conditions:  impedances are equal for each phase  voltage source phasors have equal magnitude and have a 120 deg. phase shift  a, b, c phase rotation ...
AND9038 - Efficiency Improvements Using DSN2 Schottky Diodes
AND9038 - Efficiency Improvements Using DSN2 Schottky Diodes

KB006
KB006

... Dynamic overvoltages are defined as long-term resonant overvoltages lasting many cycles and even seconds that can result in damage to capacitors, transformers, surge arresters and/or solid state power conversion equipment. In this issue of the Kilovar Briefs, we will examine the mechanism of creatin ...
Vacuum Circuit Breaker Technology
Vacuum Circuit Breaker Technology

... high energy arc which results in large amounts of metal vapor being placed in the contact zone and thereby limiting the fault rating of the interrupter. In order to improve the interrupter’s fault capacity either the spiral or axial magnetic field (AMF) contact design can be applied. These contacts ...
Power Integrations
Power Integrations

... run right through the capacitor lead pads and that no additional PC traces have been placed in series with C3. Note also that PC traces in series with L1 and the PC trace connecting C2 and C3 can be narrower and longer because current flow is essentially DC. 13) Heat sinks should be either connected ...
Sinusoidal current injection based on a line
Sinusoidal current injection based on a line

How to Select Automation Accessories for Valves T
How to Select Automation Accessories for Valves T

... signal for the positioner. The most common conversions used with control valves are For systems being controlled and monitored with electronic instrumentation but with pneumatically actuated control valves, the use of a transducer is the most practical method for interfacing the two types of equipme ...
S8VE (60/90/120/180/240-W Models)
S8VE (60/90/120/180/240-W Models)

Fuzzy Controlled Cascaded H-Bridge Multilevel Inverter
Fuzzy Controlled Cascaded H-Bridge Multilevel Inverter

SELECTRONIC™ FloWise® EXPOSED 1.6/1.1 GPF DUAL FLUSH
SELECTRONIC™ FloWise® EXPOSED 1.6/1.1 GPF DUAL FLUSH

TNY253/254/255 TinySwitch™ Family
TNY253/254/255 TinySwitch™ Family

... such as TVs. Figure 9 shows a 7.5 V, 1.3 W flyback circuit that uses TNY253 for implementing a TV standby supply. The circuit operates from the DC high-voltage already available from the main power supply. This input voltage can range from 120 to 375 VDC depending on the input AC voltage range th ...
PSS30S92F6-AG
PSS30S92F6-AG

Power capacitors
Power capacitors

Lecture 12
Lecture 12

... (hundreds of megahertz or higher) then the model would have to account for the movement of charge in and out of the depletion zone, a capacitive effect. It is important to use a model which is accurate enough to account for the necessary effects, without using so complicated a model that it is diffi ...
MX Series data sheet - AMETEK Programmable Power
MX Series data sheet - AMETEK Programmable Power

... MX45 up to 45 kVA. Both operate using single or three phase output in AC mode. In DC mode, 50% of the AC power level is available. On MX-P models, AC+DC mode is also supported. For higher power requirements, the MX90 and MX135 models are available. Multi cabinet MX45 systems always operate in three ...
Electrical Safe Work Practice
Electrical Safe Work Practice

... Qualified Person • If their work exposes them to electrical hazards which would otherwise be protected according to Subpart S – They must protect themselves against ALL the electrical hazards. • Hazards include: Shocks, Electrocution, Arc Blast, Burns, Explosions. ...
Document
Document

AN-6075 Compact Green-Mode Adapter Using FSQ500L for Low Cost 1. Introduction www.fairchildsemi.com
AN-6075 Compact Green-Mode Adapter Using FSQ500L for Low Cost 1. Introduction www.fairchildsemi.com

KT88 – TRIODE Parallel Push-Pull 60Watt Mono
KT88 – TRIODE Parallel Push-Pull 60Watt Mono

... explains and demonstrates that the THD dip is due to reversal of the relative phase of the signal current in the active load to that delivered to the subsequent grid leak. This causes the proportions of the 2nd, 3rd and 4th harmonics to change. Germane to the present discussion is that with a cathod ...
< 1 ... 234 235 236 237 238 239 240 241 242 ... 449 >

Mercury-arc valve



A mercury-arc valve or mercury-vapor rectifier or (UK) mercury-arc rectifier is a type of electrical rectifier used for converting high-voltage or high-current alternating current (AC) into direct current (DC). It is a type of cold cathode gas-filled tube, but is unusual in that the cathode, instead of being solid, is made from a pool of liquid mercury and is therefore self-restoring. As a result, mercury-arc valves were much more rugged, long-lasting and could carry much higher currents than most other types of gas discharge tube.Invented in 1902 by Peter Cooper Hewitt, mercury-arc rectifiers were used to provide power for industrial motors, electric railways, streetcars, and electric locomotives, as well as for radio transmitters and for high-voltage direct current (HVDC) power transmission. They were the primary method of high power rectification before the advent of semiconductor rectifiers, such as diodes, thyristors and gate turn-off thyristors (GTOs) in the 1970s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report