• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MDUG-CM2/14501E-01
MDUG-CM2/14501E-01

Table of Contents - Industrial Manufacturing
Table of Contents - Industrial Manufacturing

... The objective of this course is to provide a high-level overview of those products of Siemens Industry, Inc. (SII) which are sold by our channel partners and fall into the following categories: low voltage power distribution, motors, control, drives, and industrial automation. It is beyond the scope ...
Load balancing by SVC Light
Load balancing by SVC Light

PDF
PDF

... tracking maximum power points is adopted. If the maximum power level of a PV array is higher than the power rating of an MPPT, the two MPPTs will be in parallel operation to function as a single MPPT. Thus, it requires an online configuration check to determine the connection types of the two MPPTs, ...
Welcome to this module on regulated power supplies. This
Welcome to this module on regulated power supplies. This

... requiring multiple voltages, functions, or outputs requiring network control which benefit from supervisory and reset functions ...
Precision in Practice
Precision in Practice

... 10mA, producing 100mV across the 10Ω standard resistor. The effect of the changing series thermal emf can be clearly seen on the Normal Ohms readings, contributing 10mΩ for every 100µV of series thermal emf. However, the effect is reduced to virtually zero on the True Ohms readings. Close examinatio ...
MTD5P06V 5V - Red Rock Energy
MTD5P06V 5V - Red Rock Energy

... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. ...
BDTIC C C M - P F C
BDTIC C C M - P F C

MAX750A/MAX758A Adjustable, Step-Down, Current-Mode PWM Regulators _______________General Description
MAX750A/MAX758A Adjustable, Step-Down, Current-Mode PWM Regulators _______________General Description

... system coupled with a simple step-down (buck) regulator topography. Input voltages range from 4V to 11V for the MAX750A, and from 4V to 16V for the MAX758A. The current-mode PWM architecture provides cycle-bycycle current limiting, improved load transient response characteristics, and simpler outer- ...
F7 Quick Start Guide
F7 Quick Start Guide

Electronics Computer Club “the geek club”
Electronics Computer Club “the geek club”

3-in-1 Current Transformers
3-in-1 Current Transformers

... traditional current transformers in one moulded case. 3-in-1 current transformers can be directly installed next to a three-phase moulded case circuit breaker, thus saving installation time where fitting three standard individual current transformers would be required. The M3N1 range of current tran ...
PVD 3484 GB - SSD Parvex
PVD 3484 GB - SSD Parvex

irf.com - Newark
irf.com - Newark

... step-up transformer (TSU). The 24VDC bus is then stepped-up and converted to a highfrequency, 300Vp-p square-wave voltage across the secondary winding, which is used to drive the resonant output stage. The resonant tank circuit (LRES and CRES) provides the necessary transfer function for generating ...
mx321 automatic voltage regulator (avr)
mx321 automatic voltage regulator (avr)

motor starter protector
motor starter protector

motor starter protector
motor starter protector

... Thermistor Input shall be provided in case the motor or equipment arrives with integral Thermistors to monitor temperature. The Thermistor input shall provide for a motor thermal temperature monitoring that will bias the Motor Thermal Model mentioned above based on actual motor temperature. a.) The ...
Slide 1
Slide 1

... • Suppose we want to protect the motor against over load and over temperature ...
CZ36611614
CZ36611614

... A DVR has to supply energy to the load during the voltage sags. If a DVR has to supply active power over longer periods, it is convenient to provide a shunt converter that is connected to the DVR on the DC side[6]. As a matter of fact one could envisage a combination of DSTATCOM and DVR connected on ...
electrical systems on meriden triumphs
electrical systems on meriden triumphs

Phase-shifting Transformer Modeling in PSS®E
Phase-shifting Transformer Modeling in PSS®E

... adjusting the phase angle of the voltages at the phase-shifting transformer terminals. Phase-shifting transformers are also known as phase angle regulating (PAR) transformers. Phase-shifting transformers built for transmission grids are generally a three-phase, two-terminal pair design. The terminal ...
Grid Code Impact on Electrical Machine Design
Grid Code Impact on Electrical Machine Design

... circulating currents will flow in such a manner that the current produces a counter magnetic flux to cancel the linkage (Fig. 6). If these currents become sufficiently high, then overheating or other damage could occur to the outer components. The larger the V/f value is, the shorter the time the ge ...
Minimize power losses of lightly loaded flyback converters with the
Minimize power losses of lightly loaded flyback converters with the

effects of generator parameters and transformer disposal on
effects of generator parameters and transformer disposal on

Lecture 5
Lecture 5

... The phase difference between the CURRENT through the resistor and inductor A. is always zero B. is always 90o C. depends on the value of L and R D. depends on L, R and the generator voltage Electricity & Magnetism Lecture 20, Slide 18 ...
< 1 ... 150 151 152 153 154 155 156 157 158 ... 489 >

Stepper motor



A stepper motor or step motor or stepping motor is a brushless DC electric motor that divides a full rotation into a number of equal steps. The motor's position can then be commanded to move and hold at one of these steps without any feedback sensor (an open-loop controller), as long as the motor is carefully sized to the application in respect to torque and speed.Switched reluctance motors are very large stepping motors with a reduced pole count, and generally are closed-loop commutated.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report