±5V, 250mA Dual Output Power Supply (Rev. A)
... Figure 6. VPOS Boost Converter Internal Block Diagram 8.3.1.1 Switching Frequency (VPOS) The boost converter switching frequency may vary slightly as the operating conditions change, but is typically around 1.7 MHz for most operating conditions. 8.3.1.2 Output Voltage (VPOS) The boost converter's ou ...
... Figure 6. VPOS Boost Converter Internal Block Diagram 8.3.1.1 Switching Frequency (VPOS) The boost converter switching frequency may vary slightly as the operating conditions change, but is typically around 1.7 MHz for most operating conditions. 8.3.1.2 Output Voltage (VPOS) The boost converter's ou ...
Loop Selective Direction Measurement for Distance Protection
... z Not valid during single pole open condition z Not valid during single pole open condition z Not valid for three phase faults z Not valid for multiple faults (cross country fault) z Not valid close to series compensation ...
... z Not valid during single pole open condition z Not valid during single pole open condition z Not valid for three phase faults z Not valid for multiple faults (cross country fault) z Not valid close to series compensation ...
programmable countdown time switch
... turned off before the countdown is complete by pressing the on/ off button. ...
... turned off before the countdown is complete by pressing the on/ off button. ...
INTRODUCTION ON CIRCUIT SIMULATION TECHNIQUES
... ERROR: Less than 2 connections at node X The inputs to voltage-controlled sources are not considered connections during this check. This is because these inputs are ideal inputs and draw no current (they have infinite impedance). ...
... ERROR: Less than 2 connections at node X The inputs to voltage-controlled sources are not considered connections during this check. This is because these inputs are ideal inputs and draw no current (they have infinite impedance). ...
D373A Electroluminescent Lamp Driver IC
... each high frequency (HF) cycle, the voltage on the lamp is increased. At a period specified by the lamp frequency (LF) oscillator, the voltage on the lamp is discharged to ground and the polarity of the inductive charging is reversed. By this means, an alternating positive and negative voltage is de ...
... each high frequency (HF) cycle, the voltage on the lamp is increased. At a period specified by the lamp frequency (LF) oscillator, the voltage on the lamp is discharged to ground and the polarity of the inductive charging is reversed. By this means, an alternating positive and negative voltage is de ...
A-2 CPO Preinstall
... It is the responsibility of the customer to furnish and install all lighting equipment in the building before installation of bowling lanes begins. Accepted lighting on the playing surface of the lane between the foul line and the curtain wall is 20 to 25 footcandles of evenly maintained intensity m ...
... It is the responsibility of the customer to furnish and install all lighting equipment in the building before installation of bowling lanes begins. Accepted lighting on the playing surface of the lane between the foul line and the curtain wall is 20 to 25 footcandles of evenly maintained intensity m ...
MF4 4th Order Switched Capacitor Butterworth Lowpass Filter
... Note 5: The specifications for the MF4 have been given for a clock frequency (fCLK) of 250 kHz or less. Above ths clock frequency the cutoff frequency begins to deviate from the specified error band of g 0.6% but the filter still maintains its magnitude characteristics. See Application Hints. Note 6 ...
... Note 5: The specifications for the MF4 have been given for a clock frequency (fCLK) of 250 kHz or less. Above ths clock frequency the cutoff frequency begins to deviate from the specified error band of g 0.6% but the filter still maintains its magnitude characteristics. See Application Hints. Note 6 ...
MAX16961 3A, 2.2MHz, Synchronous Step-Down DC-DC Converter General Description
... voltage range and provides a 0.8V to 3.6V output voltage range. The wide input/output voltage range and the ability to provide up to 3A to load current make this device ideal for on-board point-of-load and post-regulation applications. The device achieves -3.7%/+2.6% output error over load, line, an ...
... voltage range and provides a 0.8V to 3.6V output voltage range. The wide input/output voltage range and the ability to provide up to 3A to load current make this device ideal for on-board point-of-load and post-regulation applications. The device achieves -3.7%/+2.6% output error over load, line, an ...
Zero Power Wireless Sensors Using Energy Processing
... Sensors networks are gaining widespread use in factories, industrial complexes, commercial and residential buildings, agricultural settings, and urban areas, serving to improve manufacturing efficiency, safety, reliability, automation, and security. These networks perform a variety of useful functio ...
... Sensors networks are gaining widespread use in factories, industrial complexes, commercial and residential buildings, agricultural settings, and urban areas, serving to improve manufacturing efficiency, safety, reliability, automation, and security. These networks perform a variety of useful functio ...
Datasheet - Diodes Incorporated
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... In the recent decade, the world’s electric power supply systems are widely interconnected to have the advantages like sharing of sources, diversity of loads, reduced fuel and operating cost and improved reliability [1]. The interconnection of power systems have also created problems like low frequen ...
... In the recent decade, the world’s electric power supply systems are widely interconnected to have the advantages like sharing of sources, diversity of loads, reduced fuel and operating cost and improved reliability [1]. The interconnection of power systems have also created problems like low frequen ...
MAX5188/MAX5191 Dual, 8-Bit, 40MHz, Current/Voltage, Alternate-Phase Output DACs General Description
... Dual, 8-Bit, 40MHz, Current/Voltage, Alternate-Phase Output DACs (AVDD = DVDD = +3V ±10%, AGND = DGND = 0, fCLK = 40MHz, IFS = 1mA, 400Ω differential output, CL = 5pF, TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.) ...
... Dual, 8-Bit, 40MHz, Current/Voltage, Alternate-Phase Output DACs (AVDD = DVDD = +3V ±10%, AGND = DGND = 0, fCLK = 40MHz, IFS = 1mA, 400Ω differential output, CL = 5pF, TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.) ...
Perimeter and Facility Access Hardware
... Elevator Control SAFLOK™ offers an elevator control unit (ECU) and a multi-channel elevator control unit (MCECU). The standard elevator control unit uses a single relay that will control access to certain floors. The MCECU’s most distinctive feature is that it enables up to 12 pass levels (secure s ...
... Elevator Control SAFLOK™ offers an elevator control unit (ECU) and a multi-channel elevator control unit (MCECU). The standard elevator control unit uses a single relay that will control access to certain floors. The MCECU’s most distinctive feature is that it enables up to 12 pass levels (secure s ...
TMP01 数据手册DataSheet 下载
... 357 kΩ or greater (output current 7 µA or less), the temperature setpoint hysteresis will be zero degrees. See the temperature programming discussion below. Larger values of load resistance will only decrease the output current below 7 µA and will have no effect on the operation of the device. The a ...
... 357 kΩ or greater (output current 7 µA or less), the temperature setpoint hysteresis will be zero degrees. See the temperature programming discussion below. Larger values of load resistance will only decrease the output current below 7 µA and will have no effect on the operation of the device. The a ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... Reactor design for the SVC TCR and shunt filters require special attention to current harmonics and voltage harmonics levels because dissipations in the reactors may be higher than the standard shunt reactors. The Standard IEC 289 [15] gives the definitions and suggestions for shunt reactors. IEEE s ...
... Reactor design for the SVC TCR and shunt filters require special attention to current harmonics and voltage harmonics levels because dissipations in the reactors may be higher than the standard shunt reactors. The Standard IEC 289 [15] gives the definitions and suggestions for shunt reactors. IEEE s ...
NTD24N06 - Power MOSFET, 60 V, 24 A, N-Channel
... is believed readily achievable with board mounted components. Most power electronic loads are inductive; the data in the figure is taken with a resistive load, which approximates an optimally snubbed inductive load. Power MOSFETs may be safely operated into an inductive load; however, snubbing reduc ...
... is believed readily achievable with board mounted components. Most power electronic loads are inductive; the data in the figure is taken with a resistive load, which approximates an optimally snubbed inductive load. Power MOSFETs may be safely operated into an inductive load; however, snubbing reduc ...
PRM™ Regulator 28 Vdc Input
... range input voltage. It is specifically designed to provide a controlled Factorized Bus distribution voltage for powering downstream VTM™ current multiplier — fast, efficient, isolated, low noise Point-of-Load (POL) converters. In combination, PRM modules and VTM modules form a complete DC-DC conver ...
... range input voltage. It is specifically designed to provide a controlled Factorized Bus distribution voltage for powering downstream VTM™ current multiplier — fast, efficient, isolated, low noise Point-of-Load (POL) converters. In combination, PRM modules and VTM modules form a complete DC-DC conver ...
1770-4.1, Industrial Automation Wiring and
... reduce the effects of emi and ground noise. Also, since bonding and grounding are important for safety in electrical installations, local codes and ordinances dictate which bonding and grounding methods are permissible. For example, for U.S. installations, the National Electrical Code (NEC) gives yo ...
... reduce the effects of emi and ground noise. Also, since bonding and grounding are important for safety in electrical installations, local codes and ordinances dictate which bonding and grounding methods are permissible. For example, for U.S. installations, the National Electrical Code (NEC) gives yo ...
Interharmonics: Theory and Modeling
... then it will be possible to get bins at frequencies of . These components, whatever the cause is, are defined as interharmonics. There are various causes that could lead to the previously defined interharmonic components. One example is a signal that actually contains in the frequency domain a compo ...
... then it will be possible to get bins at frequencies of . These components, whatever the cause is, are defined as interharmonics. There are various causes that could lead to the previously defined interharmonic components. One example is a signal that actually contains in the frequency domain a compo ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.