EEEE 381 Lab 5 Two-Stage Op Amp - RIT
... 1) Verify that the M6 current source is sinking approximately the designed amount of current from the differential amplifier. This can most easily be accomplished by measuring the voltage drop across the “10 ” resistor and dividing by the actual measured resistance that you recorded earlier while b ...
... 1) Verify that the M6 current source is sinking approximately the designed amount of current from the differential amplifier. This can most easily be accomplished by measuring the voltage drop across the “10 ” resistor and dividing by the actual measured resistance that you recorded earlier while b ...
Synchronous Triggering of Multiple Spark Gap Switches
... MOSFET. Synchronization mismatch delay of about 10 ns was observed which is well within the synchronous timing requirement of 50ns. This was tolerablee for simultaneous discharge of two current waveforms. The slight mismatch of triggering does not affect much the total added up current for the case ...
... MOSFET. Synchronization mismatch delay of about 10 ns was observed which is well within the synchronous timing requirement of 50ns. This was tolerablee for simultaneous discharge of two current waveforms. The slight mismatch of triggering does not affect much the total added up current for the case ...
SML-020MLTT86PN - ROHM Co., Ltd.
... case temperature characteristics for each LED type.) Storage precautions Storage in a dry box is best. However, if this is not possible we recommend the following conditions : Temperature : 5 to 30C Humidity : 60%RH max. Recommended PCB We recommend the following hole diameters. Note, however, th ...
... case temperature characteristics for each LED type.) Storage precautions Storage in a dry box is best. However, if this is not possible we recommend the following conditions : Temperature : 5 to 30C Humidity : 60%RH max. Recommended PCB We recommend the following hole diameters. Note, however, th ...
Electricity and Magnetism: 4.F.1 Simple Circuits
... 3. 3-5.PS.4 Recognize that electricity in circuits requires a complete loop through which an electrical current can pass, and that electricity can produce light, heat and sound. 4. 3-5.TE.1.2 Identify and explain the appropriate materials and tools (e.g., hammer, screwdriver, pliers, tape measure, s ...
... 3. 3-5.PS.4 Recognize that electricity in circuits requires a complete loop through which an electrical current can pass, and that electricity can produce light, heat and sound. 4. 3-5.TE.1.2 Identify and explain the appropriate materials and tools (e.g., hammer, screwdriver, pliers, tape measure, s ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
... current limiting, thermal shut down and safe operating area protection, making it essentially indestructible. If adequate heat sinking is provided, they can deliver over 1A output current. Although designed primarily as fixed voltage regulators, these devices can be used with external components to ...
... current limiting, thermal shut down and safe operating area protection, making it essentially indestructible. If adequate heat sinking is provided, they can deliver over 1A output current. Although designed primarily as fixed voltage regulators, these devices can be used with external components to ...
DS1090 Low-Frequency, Spread-Spectrum EconOscillator General Description
... The DS1090 is a low-cost, dithered oscillator intended to be used as an external clock for switched-mode power supplies and other low-frequency applications. The dithering or sweeping function reduces peak-radiated emissions from the power supply at its fundamental frequency, as well as harmonic fre ...
... The DS1090 is a low-cost, dithered oscillator intended to be used as an external clock for switched-mode power supplies and other low-frequency applications. The dithering or sweeping function reduces peak-radiated emissions from the power supply at its fundamental frequency, as well as harmonic fre ...
AD8016
... may cause a shift in parametric performance due to a change in the stresses exerted on the die by the package. The output stage of the AD8016 is designed for maximum load current capability. As a result, shorting the output to common can cause the AD8016 to source or sink 2000 mA. To ensure proper o ...
... may cause a shift in parametric performance due to a change in the stresses exerted on the die by the package. The output stage of the AD8016 is designed for maximum load current capability. As a result, shorting the output to common can cause the AD8016 to source or sink 2000 mA. To ensure proper o ...
Manual - BestConverter
... Distributed in the U.S.A. and Canada by CHENG USA, INC. Sales (574) 294-8997 Warranty Service (877) 294-8997 Fax (574) 294-8698 ...
... Distributed in the U.S.A. and Canada by CHENG USA, INC. Sales (574) 294-8997 Warranty Service (877) 294-8997 Fax (574) 294-8698 ...
Electrical Safety
... flowing through a pipe. In order to have a flow of water three things must occur. First, there must be a source of water, like a reservoir. Second, the water must be transported on or in something... like a pipe. Third, there must be a source of pressure, like a water pump, to make the water flow. E ...
... flowing through a pipe. In order to have a flow of water three things must occur. First, there must be a source of water, like a reservoir. Second, the water must be transported on or in something... like a pipe. Third, there must be a source of pressure, like a water pump, to make the water flow. E ...
MAX848/MAX849 1-Cell to 3-Cell, High-Power, Low-Noise, Step-Up DC-DC Converters General Description
... The MAX848/MAX849 boost converters set a new standard of high efficiency and high integration for noisesensitive power-supply applications, such as portable phones and small systems with RF data links. The heart of the these devices is a synchronous boost-topology regulator that generates a fixed 3. ...
... The MAX848/MAX849 boost converters set a new standard of high efficiency and high integration for noisesensitive power-supply applications, such as portable phones and small systems with RF data links. The heart of the these devices is a synchronous boost-topology regulator that generates a fixed 3. ...
CNT devices
... There is a clear difference in the inverse subthreshold slope for the case of sweeping all gate segments together (S=400 mV/dec) versus sweeping only the inner segments (S=180 mV/dec). We attribute the observed change in S to a change from Schottky barrier modulation to bulk switching. (b) shows li ...
... There is a clear difference in the inverse subthreshold slope for the case of sweeping all gate segments together (S=400 mV/dec) versus sweeping only the inner segments (S=180 mV/dec). We attribute the observed change in S to a change from Schottky barrier modulation to bulk switching. (b) shows li ...
CN-0081 利用电流源DAC AD5410提供12位、4 mA至20 mA输出简化解决方案
... The AD5410 is a low-cost, highly integrated 12-bit digital-toanalog converter offering a programmable current source output designed to meet the requirements of industrial process control applications. The current output can be programmed with ranges of 4 mA to 20 mA, 0 mA to 20 mA, or 0 mA to 24 mA ...
... The AD5410 is a low-cost, highly integrated 12-bit digital-toanalog converter offering a programmable current source output designed to meet the requirements of industrial process control applications. The current output can be programmed with ranges of 4 mA to 20 mA, 0 mA to 20 mA, or 0 mA to 24 mA ...
EET 163 B232
... Additional labs and homework may be assigned during the quarter. In case of inclement weather, call my office number for class cancellation information ...
... Additional labs and homework may be assigned during the quarter. In case of inclement weather, call my office number for class cancellation information ...
SPS-5 and SPS-10 Technical Sales Bulletin
... Supervised Distribution Module (Fuses) AQM20 with Smart Fan and PDB-8C8R -8C8R Supervised Distribution Module (circuit breakers) ...
... Supervised Distribution Module (Fuses) AQM20 with Smart Fan and PDB-8C8R -8C8R Supervised Distribution Module (circuit breakers) ...
MAX17242/MAX17243 3.5V–36V, 2A/3A, Synchronous Buck
... The MAX17242/MAX17243 are 2A/3A current-mode stepdown converters with integrated high-side and lowside MOSFETs. The low-side MOSFET enables fixedfrequency, forced-PWM operation in light-load applications. The devices operate with input voltages from 3.5V to 36V while using only 15µA quiescent curren ...
... The MAX17242/MAX17243 are 2A/3A current-mode stepdown converters with integrated high-side and lowside MOSFETs. The low-side MOSFET enables fixedfrequency, forced-PWM operation in light-load applications. The devices operate with input voltages from 3.5V to 36V while using only 15µA quiescent curren ...
Step-Down DC/DC Controller TLE 6389
... a 100% duty cycle, resulting in very low dropout voltage. This control scheme eliminates minimum load requirements and reduces the supply current under light loads to 120µA, depending on dimensioning of external components. In addition the adjustable version TLE6389-2 GV can be shut down via the Ena ...
... a 100% duty cycle, resulting in very low dropout voltage. This control scheme eliminates minimum load requirements and reduces the supply current under light loads to 120µA, depending on dimensioning of external components. In addition the adjustable version TLE6389-2 GV can be shut down via the Ena ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.