Morse/PSK Reader Specification: Limitations:
... Figure 1: Frequency roll off (dB/Hz) when 8 values are averaged at 40ksamples / second At the next step the signal is mixed with quadrature (I/Q) oscillator running at 625Hz, low pass filtered with 51 tap FIR filter and 16x decimated, resulting in an I/Q data stream of 312.5 samples per second, see ...
... Figure 1: Frequency roll off (dB/Hz) when 8 values are averaged at 40ksamples / second At the next step the signal is mixed with quadrature (I/Q) oscillator running at 625Hz, low pass filtered with 51 tap FIR filter and 16x decimated, resulting in an I/Q data stream of 312.5 samples per second, see ...
Summary of PhD Projects 2013
... Over the last decades, the worldwide interest in renewable energy sources has risen drastically. At this stage the generation of electrical power via wind turbines is one of the most promising renewable sources. Primarily, in Europe the installed power has risen drastically so that wind power is tod ...
... Over the last decades, the worldwide interest in renewable energy sources has risen drastically. At this stage the generation of electrical power via wind turbines is one of the most promising renewable sources. Primarily, in Europe the installed power has risen drastically so that wind power is tod ...
SKiiP3 F-option (2014-09-30 - Rev-01) Technical
... 2 Application and handling instructions .............................................................................................................. 4 ...
... 2 Application and handling instructions .............................................................................................................. 4 ...
Series 30xx - Lehner
... 6. All efficiency figures (ŋ) contain losses of motor and controller. Total efficiency of 94% contains a controller loss of ca. 1 - 2% which corresponds to a pure motor efficiency of ca. 95 - 96%. 7. Series 30xx motors are optimized for partial load through finely segmented rotors. 8. The temperatur ...
... 6. All efficiency figures (ŋ) contain losses of motor and controller. Total efficiency of 94% contains a controller loss of ca. 1 - 2% which corresponds to a pure motor efficiency of ca. 95 - 96%. 7. Series 30xx motors are optimized for partial load through finely segmented rotors. 8. The temperatur ...
MAX5363/MAX5364/MAX5365 Low-Cost, Low-Power, 6-Bit DACs with 3-Wire Serial Interface in SOT23 General Description
... the overall accuracy of the DAC. The circuit in Figure 5 rejects this power-supply noise by powering the device directly with a precision voltage reference, improving overall system accuracy. The MAX6103 (+3V, 75ppm) or the MAX6105 (+5V, 75ppm) precision voltage references are ideal choices due to t ...
... the overall accuracy of the DAC. The circuit in Figure 5 rejects this power-supply noise by powering the device directly with a precision voltage reference, improving overall system accuracy. The MAX6103 (+3V, 75ppm) or the MAX6105 (+5V, 75ppm) precision voltage references are ideal choices due to t ...
Complete Technical Specifications
... A grid-tied solar array may be a few panels or many in series, and may range from a few 12 volt panels to high voltage multi-panel arrays for grid-tied systems. Grid-tied systems can go as high as 1000 VDC, while off-grid battery systems are typically 12, 24 or 48V. Higher voltage systems (over 48V) ...
... A grid-tied solar array may be a few panels or many in series, and may range from a few 12 volt panels to high voltage multi-panel arrays for grid-tied systems. Grid-tied systems can go as high as 1000 VDC, while off-grid battery systems are typically 12, 24 or 48V. Higher voltage systems (over 48V) ...
Predicting Circuit Board Hot Spots with Electrothermal
... Excessive heat is the enemy of electronic parts, especially integrated circuits (ICs) in densely packed, power-hungry electronic devices. Increased levels of electrical current requirements in these applications must be considered in the printed circuit board (PCB) design to combat the generation of ...
... Excessive heat is the enemy of electronic parts, especially integrated circuits (ICs) in densely packed, power-hungry electronic devices. Increased levels of electrical current requirements in these applications must be considered in the printed circuit board (PCB) design to combat the generation of ...
Balun or Unun
... Ferrite saturates at a lower given power than iron, but has wider frequency capability Permeability (power handling) When a core exceeds rated permeability, the coil acts like plain wire. Voltage breakdown of windings Useable frequency (which mix to use) Efficiency (power loss) ...
... Ferrite saturates at a lower given power than iron, but has wider frequency capability Permeability (power handling) When a core exceeds rated permeability, the coil acts like plain wire. Voltage breakdown of windings Useable frequency (which mix to use) Efficiency (power loss) ...
R-MAG®Medium Voltage Tank Vacuum Magnetic
... has more stroke than the vacuum interrupter and the interrupter contacts make contact before the actuator has completed the stroke. The additional movement of the operating rod after the contact closing causes the contact pressure spring to compress at the top of the operating rod. This wipe allows ...
... has more stroke than the vacuum interrupter and the interrupter contacts make contact before the actuator has completed the stroke. The additional movement of the operating rod after the contact closing causes the contact pressure spring to compress at the top of the operating rod. This wipe allows ...
Residential Load Models for Network Planning Purposes
... consumption. They can be combined as base load. The refrigerator is not shown in fig. 2, but its impact on the energy consumption of a household is significant and the peak power is between 80 W to 150 W. C. Classification of Residential Customers Variations in the consumption are not only due to th ...
... consumption. They can be combined as base load. The refrigerator is not shown in fig. 2, but its impact on the energy consumption of a household is significant and the peak power is between 80 W to 150 W. C. Classification of Residential Customers Variations in the consumption are not only due to th ...
MAX44265 Evaluation Kit Evaluates: MAX44265 General Description Features
... The MAX44265 evaluation kit (EV kit) provides a proven design to evaluate the MAX44265 low-power, MOS-input operational amplifier (op amp) in a 6-bump wafer-level package (WLP). The EV kit circuit is preconfigured as a noninverting amplifier, but can easily be adapted to other topologies by changing ...
... The MAX44265 evaluation kit (EV kit) provides a proven design to evaluate the MAX44265 low-power, MOS-input operational amplifier (op amp) in a 6-bump wafer-level package (WLP). The EV kit circuit is preconfigured as a noninverting amplifier, but can easily be adapted to other topologies by changing ...
AN4026
... The L6699 enables the user to set the operating frequency range of the converter by means of a high-accuracy externally programmable oscillator. At startup, in addition to the traditional frequency-shift soft-start (the switching frequency starts from a preset maximum value and then decays as far as ...
... The L6699 enables the user to set the operating frequency range of the converter by means of a high-accuracy externally programmable oscillator. At startup, in addition to the traditional frequency-shift soft-start (the switching frequency starts from a preset maximum value and then decays as far as ...
E3F2-240VAC - RFD electronic GmbH
... OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and ...
... OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.