• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX1098/MAX1099 10-Bit Serial-Output Temperature Sensors with 5-Channel ADC General Description
MAX1098/MAX1099 10-Bit Serial-Output Temperature Sensors with 5-Channel ADC General Description

... using +5V and +3V supply voltages, respectively. Accuracy is ±1°C from 0°C to +70°C, with no calibration needed. The devices feature an algorithmic switched-capacitor analog-to-digital converter (ADC), on-chip clock, and 3-wire serial interface compatible with SPI™, QSPI™, and MICROWIRE™. The MAX109 ...
Surge Protectors
Surge Protectors

... Surge protector (uses 15A wall plug and 15A receptacles.) This has 20A electronics for more heavy duty use. ...
DOMINATOR HD MODEL 1071 USER MANUAL Revision A   05/09/2014
DOMINATOR HD MODEL 1071 USER MANUAL Revision A 05/09/2014

Single/Dual/Quad, Ultra-High-Speed, +3V/+5V, Beyond-the
Single/Dual/Quad, Ultra-High-Speed, +3V/+5V, Beyond-the

... Note 4: Input offset voltage is defined as the mean of the trip points. Note 5: CMRR = (VOSL - VOSH) / 5.2V, where VOSL is the offset at VCM = -0.1V and VOSH is the offset at VCM = 5.1V. Note 6: PSRR = (VOS2.7 - VOS5.5) / 2.8V, where VOS2.7 is the offset voltage at VCC = 2.7V, and VOS5.5 is the offs ...
Power Measurement
Power Measurement

TPS54A20 8-V to 14-V Input, 10-A, up to 10
TPS54A20 8-V to 14-V Input, 10-A, up to 10

... capacitor buck converter designed for small size, low voltage applications from a 12-V input rail. This topology uniquely merges a switched capacitor circuit with a two phase buck converter. Advantages include automatic current balancing between the inductors, lower switching losses which enable hig ...
MB39C602 - Fujitsu
MB39C602 - Fujitsu

... MB39C602 is a flyback type switching regulator controller. The LED current is regulated by controlling the switching on-time depending on the LED load.The LED current is converted into detecting voltage (Vs) by sense resistor (Rs) connected in series with LED. Vs is compared by an external error amp ...
REFURBISHMENT and VERIFICATION of the HEATHKIT TT
REFURBISHMENT and VERIFICATION of the HEATHKIT TT

... Connect the leads of an AC voltmeter to SX21 (see Figure) and CD1 (see Figure)  (use the 150 volt range or higher). Turn the  instrument  ON  and  adjust the line  voltage (pull down the LINE TEST switch and adjust the meter to the LINE CHECK  arrow with the SET LINE control). For all voltage posit ...
How to test an electric motor?
How to test an electric motor?

... Insulation resistance of motor winding using Insulation tester meter set to the 500 Volt scale (1000v DC). 1. Check from phase to phase (U to V, V to W, W to U) and 2. check from phase to earthing ( U to E, V to E , W to E ). Minimum test value of the electric motor is 1 Meg Ohm (1 MΩ). With the mot ...
Power Measurement
Power Measurement

... the relative uncertainty in active power measurements can be shown to be equal to –εwtgϕ. The phase uncertainty depends on the frequency. By using more complex circuits, the frequency range of the dynamometer can be extended to a few tens of kilohertz. The above has presented the power definitions a ...
Optimization of Electrochemical Wet Etching of Silver STM
Optimization of Electrochemical Wet Etching of Silver STM

... Once the proper elements are arranged as shown a voltage between 15 and 27 voltage is applied to the electrochemical circuit. For most etching purposes the ideal voltage to apply is approximately 24 volts. When the DC voltage source is switched on small bubbles may appear around the apex of the tip, ...
PAM2306D Description Pin Assignments
PAM2306D Description Pin Assignments

... This formula has a maximum at VIN =2VOUT, where IRMS = IOUT/2. This simple worst-case condition is commonly used for design because even significant deviations do not offer much relief. Note that the capacitor manufacturer's ripple current ratings are often based on 2000 hours of life. This makes it ...
Unit number- 2461038
Unit number- 2461038

... standards set out in the outcomes, performance criteria, range statements and evidence requirements. To achieve a merit in this unit, a candidate must demonstrate a superior or more sophisticated level of performance. In this unit this might be demonstrated by the use of more complex measurement tec ...
MAX9150 Low-Jitter, 10-Port LVDS Repeater Ordering Information Typical Application Circuit
MAX9150 Low-Jitter, 10-Port LVDS Repeater Ordering Information Typical Application Circuit

... intended for point-to-point communication over a controlled impedance medium, as defined by the ANSI/TIA/EIA-644 and IEEE 1596.3 standards. The LVDS standard uses a lower voltage swing than other common communication standards, achieving higher data rates with reduced power consumption while reducin ...
Typical Current Transformer
Typical Current Transformer

... Current transformers can reduce or “step-down” current levels from thousands of amperes down to a standard output of a known ratio to either 5 Amps or 1 Amp for normal operation. Thus, small and accurate instruments and control devices can be used with CT’s because they are insulated away from any h ...
LTM2885 - 6500VRMS Isolated RS485/RS422
LTM2885 - 6500VRMS Isolated RS485/RS422

... Note 4: This µModule transceiver includes over temperature protection that is intended to protect the device during momentary overload conditions. Junction temperature will exceed 125°C when over temperature protection is active. Continuous operation above specified maximum operating junction temper ...
Chapter 12
Chapter 12

Monolite Operating Manual Alcad.qxd
Monolite Operating Manual Alcad.qxd

... These effects can be avoided by using the correct charger; it must feature voltage regulation, with the battery disconnected, of ±1% from no load to full load under all operating conditions; and under full load with the battery disconnected, the peak-to-peak voltage must fall within ±2.5% of the re ...
A Static Power Model for Architects
A Static Power Model for Architects

Tower Electronic Systems
Tower Electronic Systems

... The Tower 3300 series of three phase double conversion Uninterruptible Power Supplies (UPS) provide quiet, reliable and continuous power to an external load. The load is protected against input transients and the output frequency is controlled to within specified parameters. In the event of a power ...
NCP1653(PFC controller)
NCP1653(PFC controller)

... This pin sources a current IS which is proportional to the inductor current IL. The sense currentIS is for overcurrent protection (OCP), overpower limitation (OPL) and PFC duty cycle://www.51wendang.com/doc/f7620cb6d9e460b5302d697car modulation. When IS goes above 200 mA, OCP is activated and the Dr ...
Ch12_PPT_Fund_Elec_Circ_5e
Ch12_PPT_Fund_Elec_Circ_5e

... • This chapter will introduce the concept of three phase AC power. • The two configurations for sources and loads for three phase circuitry will be discussed. • The different schemes for connecting these two configurations will be covered. ...
ID Innovations - Purdue Engineering
ID Innovations - Purdue Engineering

... license, express or implied, by estoppel or otherwise, to any intellectual property right is granted by this document or in connection with the sale of ID-Innovations products. Except as set forth in ID-Innovations Terms and Conditions of Sale, ID-Innovations assumes no liability whatsoever and disc ...
GC3510651086
GC3510651086

... power supplied to electrical equipment from the steady 50 Hz, sinusoidal waveform of voltage or current. These deviations may affect the safe or reliable operation of equipment such as computers. Thus terms like “poor power quality” mean that there is ample deviation from norms in the power supply t ...
Determination of energy barrier profiles for high-k
Determination of energy barrier profiles for high-k

... layers. By measuring current at both positive and negative voltages, we are able to measure the band offsets from Si and also to determine the flatband voltage and the barrier asymmetry at 0 V. Our SiO2 calibration sample yielded a conduction band offset value of 3.03± 0.1 eV. Measurements on HfO2 g ...
< 1 ... 758 759 760 761 762 763 764 765 766 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report