generic specification for high performance
... Power meter shall provide advanced metering data integration with the web. 1. Ethernet communication architecture shall be available, which shall allow user to display metering data, and host meter power information website directly within meter. 2. Meter shall provide direct access to all power dat ...
... Power meter shall provide advanced metering data integration with the web. 1. Ethernet communication architecture shall be available, which shall allow user to display metering data, and host meter power information website directly within meter. 2. Meter shall provide direct access to all power dat ...
Libro blanco Tecnología piezoeléctrica en válvulas neumáticas
... Piezo valves are often a better alternative to conventional solenoid valves, especially in the areas of flow and pressure control and as directly controlled proportional valves. They are small, lightweight, extremely precise, very durable, incredibly fast and above all they save energy. For example, ...
... Piezo valves are often a better alternative to conventional solenoid valves, especially in the areas of flow and pressure control and as directly controlled proportional valves. They are small, lightweight, extremely precise, very durable, incredibly fast and above all they save energy. For example, ...
Differential Signaling
... A differential receiver is tolerant of its ground moving around. If each “wire” of pair is on close proximity of one and other. electromagnetic interference imposes the same voltage on both signals. The difference cancels out the effect. Since the AC currents in the “wires” are equal but opposite an ...
... A differential receiver is tolerant of its ground moving around. If each “wire” of pair is on close proximity of one and other. electromagnetic interference imposes the same voltage on both signals. The difference cancels out the effect. Since the AC currents in the “wires” are equal but opposite an ...
TWL92230C 数据资料 dataSheet 下载
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
Earth fault protection in isolated and compensated
... This report presents theory on transformer neutral earthing, earth fault protection and simulations on a real 22 kV power distribution system in ATPDraw provided by Statkraft. The report consists of three main parts. The first part presents a problem description and theory, the second part presents ...
... This report presents theory on transformer neutral earthing, earth fault protection and simulations on a real 22 kV power distribution system in ATPDraw provided by Statkraft. The report consists of three main parts. The first part presents a problem description and theory, the second part presents ...
MC33814, Two cylinder small engine control IC - Data Sheet
... Powered by SMARTMOS technology, the 33814 delivers a cost-optimized IC solution for managing one and two-cylinder engines. With six drivers, three predrivers, a 5.0 V regulator for the MCU, a protected external sensor supply, and a high level of integration, the IC offers an ideal response to contem ...
... Powered by SMARTMOS technology, the 33814 delivers a cost-optimized IC solution for managing one and two-cylinder engines. With six drivers, three predrivers, a 5.0 V regulator for the MCU, a protected external sensor supply, and a high level of integration, the IC offers an ideal response to contem ...
Rectification - NYCC SP-01
... Self-rectification is usually limited to dental and portable units. The highest limits are about 30 MA. at 90 kV. They are limited so because overstepping these bounds can cause temperature rise in the anode target to the point of thermionic emission. In this event the inverse voltage can drive thes ...
... Self-rectification is usually limited to dental and portable units. The highest limits are about 30 MA. at 90 kV. They are limited so because overstepping these bounds can cause temperature rise in the anode target to the point of thermionic emission. In this event the inverse voltage can drive thes ...
14 Millimeter Thread, 3/8” Reach, 13/16” Hex
... was found to improve performance in four-stroke engines as well. All operate on primarily the same principle, a spark plug with fine wire electrodes will perform better than a traditional plug. There are two reasons for this, first is because a smaller center electrode requires less voltage to jump ...
... was found to improve performance in four-stroke engines as well. All operate on primarily the same principle, a spark plug with fine wire electrodes will perform better than a traditional plug. There are two reasons for this, first is because a smaller center electrode requires less voltage to jump ...
Instructions for IQ Analyzer Electrical Distribution System Monitor
... 5-11.1 Organization of Data .............................. 5-25 5-11.2 Display of Trend Data ............................ 5-25 5-11.3 Programming of Trend Parameters ........ 5-26 5-11.4 Applications of Trending ........................ 5-28 5-12 Event Log Operation (NEW!) ....................... 5- ...
... 5-11.1 Organization of Data .............................. 5-25 5-11.2 Display of Trend Data ............................ 5-25 5-11.3 Programming of Trend Parameters ........ 5-26 5-11.4 Applications of Trending ........................ 5-28 5-12 Event Log Operation (NEW!) ....................... 5- ...
VSOP98260 Preamplifier Circuit for IR Remote Control
... typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in ...
... typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in ...
model iq12-2600
... Automatic shutoff for Low Battery Automatic shutoff for Overload Automatic momentary shutoff/restart for Over Temperature All controls accessible from the front AC input/output hardwire box Load Demand including Automatic Throttle Control (1 amp ground signal) Load Demand Enable/Disable Switch Built ...
... Automatic shutoff for Low Battery Automatic shutoff for Overload Automatic momentary shutoff/restart for Over Temperature All controls accessible from the front AC input/output hardwire box Load Demand including Automatic Throttle Control (1 amp ground signal) Load Demand Enable/Disable Switch Built ...
NPCC Directory 4 System Protection Criteria
... General Criteria The intent of the criteria established in this Directory is to ensure dependable and secure operation of the protection systems for bulk power system. For those protective relays intended for removal of faults from the bulk power system, dependability is paramount, and the redundanc ...
... General Criteria The intent of the criteria established in this Directory is to ensure dependable and secure operation of the protection systems for bulk power system. For those protective relays intended for removal of faults from the bulk power system, dependability is paramount, and the redundanc ...
ADM9690 数据手册DataSheet 下载
... 60 ms (RESET(2)) after VMON climbs above the reset threshold. RESET(1) is intended to provide a power-on reset signal for the µP while RESET(2) is used to hold additional circuitry in a reset state until the µP has regained control following a power-up. The voltage monitoring circuitry remains opera ...
... 60 ms (RESET(2)) after VMON climbs above the reset threshold. RESET(1) is intended to provide a power-on reset signal for the µP while RESET(2) is used to hold additional circuitry in a reset state until the µP has regained control following a power-up. The voltage monitoring circuitry remains opera ...
Operating And Service Instructions - AT30 Charger
... APPENDIX C: Standard Drawings * Outline: AT30 Battery Charger NEMA-1 Style-5018 Enclosure .................................................... 66 Outline: AT30 Battery Charger NEMA-1 Style-5030 Enclosure .................................................... 68 Outline: AT30 Battery Charger NEMA-1 Sty ...
... APPENDIX C: Standard Drawings * Outline: AT30 Battery Charger NEMA-1 Style-5018 Enclosure .................................................... 66 Outline: AT30 Battery Charger NEMA-1 Style-5030 Enclosure .................................................... 68 Outline: AT30 Battery Charger NEMA-1 Sty ...
A21 Dimming System
... 1.) Power connections shall be made on compression screw terminals. Control signal connections shall be made via plug-in connectors at each module chassis. 2.) Load connections shall be via compression screw terminals on a terminal block. 3.) Power Modules shall be suitable for 120V or 277V, 60Hz. 4 ...
... 1.) Power connections shall be made on compression screw terminals. Control signal connections shall be made via plug-in connectors at each module chassis. 2.) Load connections shall be via compression screw terminals on a terminal block. 3.) Power Modules shall be suitable for 120V or 277V, 60Hz. 4 ...
NBSG11 2.5V/3.3V SiGe 1:2 Differential Clock Driver with RSECL* Outputs
... NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared operating temperature range. Functiona ...
... NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared operating temperature range. Functiona ...
CD4538BC Dual Precision Monostable
... active LOW and prevent triggering while active. Precise control of output pulse-width has been achieved using linear CMOS techniques. The pulse duration and accuracy are determined by external components RX and CX. The device does not allow the timing capacitor to discharge through the timing pin on ...
... active LOW and prevent triggering while active. Precise control of output pulse-width has been achieved using linear CMOS techniques. The pulse duration and accuracy are determined by external components RX and CX. The device does not allow the timing capacitor to discharge through the timing pin on ...
table of contents
... Note: The internal oscillator of the MFJ-259 will not produce an entirely stable reading on the frequency display due to short term drift in the oscillator. This drift is normal and does not affect the accuracy, results or usefulness of this instrument since a null will even be maintained on the hig ...
... Note: The internal oscillator of the MFJ-259 will not produce an entirely stable reading on the frequency display due to short term drift in the oscillator. This drift is normal and does not affect the accuracy, results or usefulness of this instrument since a null will even be maintained on the hig ...
PCA9515A 1. General description I
... more devices or longer length can be accommodated. It can also be used to run two buses, one at 5 V and the other at 3.3 V or a 400 kHz and 100 kHz bus, where the 100 kHz bus is isolated when 400 kHz operation of the other is required. Two or more PCA9515As cannot be put in series. The PCA9515A desi ...
... more devices or longer length can be accommodated. It can also be used to run two buses, one at 5 V and the other at 3.3 V or a 400 kHz and 100 kHz bus, where the 100 kHz bus is isolated when 400 kHz operation of the other is required. Two or more PCA9515As cannot be put in series. The PCA9515A desi ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.