• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Ethernet force-distance measurement system, 1 counter input, 4
Ethernet force-distance measurement system, 1 counter input, 4

DAC7724 数据资料 dataSheet 下载
DAC7724 数据资料 dataSheet 下载

... Short-Circuit Current Short-Circuit Duration ...
File
File

... In a parallel series, each line of wire has a different amount of amps. When added the amps together, you get the total amount of amps in the entire circuit. ...
SD101AWS – SD101CWS Features Mechanical Data
SD101AWS – SD101CWS Features Mechanical Data

... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Introduction to Short Circuit Current Calculations
Introduction to Short Circuit Current Calculations

MAX13041 ±80V Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN
MAX13041 ±80V Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN

... the physical bus wires of the controller area network and allows communication at speeds up to 1Mbps. The extended fault-protected voltage range of ±80V on CAN bus lines allows for use in +12V or +42V automotive, and higher voltage +24V and +36V mid-heavy truck applications. Advanced power managemen ...
AN10739 Discrete LED driver Rev. 2 — 21 June 2010 Application note
AN10739 Discrete LED driver Rev. 2 — 21 June 2010 Application note

... LED forward voltage VF, the peak current Imax, and the inductor value L (see Equation 8). With given input conditions one can calculate the resulting switching frequency for different values of L to get a guideline for the choice of the inductor. In general, L shall be as small as possible to reduce ...
II. proposed ELECTRONIC BALLAST
II. proposed ELECTRONIC BALLAST

... lamps are substituting the 40W/T12, in the future 28W/T5 will go to substitute the 32W/T8. The T5 fluorescent lamps had been developed especially to operate with electronic ballast and provide high efficiency when fed in high frequency. As these lamps are more expensive than standard fluorescent lam ...
View_pdf - International Journal of Computer Science and Mobile
View_pdf - International Journal of Computer Science and Mobile

SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES

... In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood of equipment dielectric failure. Several components can be used to limit and/or eliminate the surges. This document provides general s ...
Circuit Note - Analog Devices
Circuit Note - Analog Devices

... driver circuit is in the high performance mode (VCC = 12 V), S1 is open, and the overall gain is 0.35. The input drive to the resolver is 18 V p-p (differential), and the SIN/COS outputs are 9 V p-p differential because the resolver transformation ratio is 0.5. The 9 V p-p differential is 4.5 V p-p ...
Grounding and bonding portable generators and stages
Grounding and bonding portable generators and stages

Si3402EV: Non-Isolated Evaluation Board for the Si3402
Si3402EV: Non-Isolated Evaluation Board for the Si3402

... For the standard ESR capacitor, the ESR increase at very low temperatures may cause a loop stability issue. A typical evaluation board has been shown to exhibit instability under very heavy loads at –20 °C. Due to self-heating, this condition is not a great concern. However, using a low ESR filter c ...
Chapter 1 AN OVERVIEW OF HARMONICS MODELING AND
Chapter 1 AN OVERVIEW OF HARMONICS MODELING AND

... Frequency Scan: The frequency scan is usually the first step in a harmonic study. A frequency or impedance scan is a plot of the driving point (Thevenin) impedance at a system bus versus frequency. The bus of interest is one where a harmonic source exists. For simple system this impedance can be obt ...
Hardware Setup
Hardware Setup

... 2. Locate a small dot marked on the top surface of the CPU close to one if it's corners. The same corner will also be cut off, leaving a noticeable notch in the CPU's corner. These markings indicate Pin 1 of the CPU. 3. Pull up the lever of Socket 462 so that it is perpendicular with the surface of ...
Clamp Meter - East Hills Instruments
Clamp Meter - East Hills Instruments

... Never measure current while the test leads are inserted into the input jacks. Make sure the battery door is closed and latched before operating the Meter. Remove the test leads from the Meter before the battery door is opened. Examine the test leads for damaged insulation or exposed metal. Check tes ...
AAT3200 数据资料DataSheet下载
AAT3200 数据资料DataSheet下载

... The AAT3200 is protected by both current limit and overtemperature protection circuitry. The internal short-circuit current limit is designed to activate when the output load demand exceeds the maximum rated output. If a short-circuit condition were to continually draw more than the current limit th ...
ComfortG2
ComfortG2

... BPM01 Module not required. • Prevents over-discharge of battery • Current limits charging current to a low battery ...
Aalborg Universitet Active harmonic filtering using current-controlled, grid-connected DG units with
Aalborg Universitet Active harmonic filtering using current-controlled, grid-connected DG units with

... To compensate distribution system harmonic distortions, a number of active and passive filtering methods have been developed [3]. However, installing additionally filters is not very favorable due to cost concerns. Alternatively, distribution system power quality enhancement using flexible control o ...
an electrothermally-driven low voltage micro switch for high
an electrothermally-driven low voltage micro switch for high

TPS61194-Q1 Low-EMI Automotive LED Driver With 4 100
TPS61194-Q1 Low-EMI Automotive LED Driver With 4 100

... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absol ...
ISL90460 - Intersil
ISL90460 - Intersil

Harmonic mitigation Solution Handbook
Harmonic mitigation Solution Handbook

... They are commonly used up to about 500kW unit power or 1,000kW total drives power. In this power range the transformer should be at least 2.5 times the drives load. Depending on the transformer size and cabling, the resulting THDu will be up to ~6%. This could give possible nuisance, but is usually ...
Battery Balancer
Battery Balancer

ADD71 Manual
ADD71 Manual

... DANGER ........................................................................................... - 2 Danger............................................................................................... - 3 SPECIFICATION ............................................................................. ...
< 1 ... 637 638 639 640 641 642 643 644 645 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report