LTC4080X
... may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The LTC4080X is guaranteed to meet performance specifications from 0°C to 85°C. Specifications over the –40°C to 85°C operating temperatu ...
... may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The LTC4080X is guaranteed to meet performance specifications from 0°C to 85°C. Specifications over the –40°C to 85°C operating temperatu ...
Frequency Response of Filters - ECE, Rutgers
... NOTE: The oscillator is designed to work for a very wide range of frequencies but may not be stable at very low frequencies, say in the order of 100 Hz or 200Hz. To start with it is a good idea to have the circuit working at some mid-range frequency, say in the order of 1K Hz or 2K Hz, and then chan ...
... NOTE: The oscillator is designed to work for a very wide range of frequencies but may not be stable at very low frequencies, say in the order of 100 Hz or 200Hz. To start with it is a good idea to have the circuit working at some mid-range frequency, say in the order of 1K Hz or 2K Hz, and then chan ...
FJP5555 NPN Silicon Transistor FJP5555 — NPN Silicon T
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
Errata - Silicon Labs
... 2.5 EMU_E214 – Device Erase Cannot Occur if Voltage Scaling Level is Too Low Description of Errata The device erase logic does not check the Voltage Scale Level prior to attempting a device erase. If using Voltage Scale Level 0 (1 V), the device may not be able to erase the flash. This results in a ...
... 2.5 EMU_E214 – Device Erase Cannot Occur if Voltage Scaling Level is Too Low Description of Errata The device erase logic does not check the Voltage Scale Level prior to attempting a device erase. If using Voltage Scale Level 0 (1 V), the device may not be able to erase the flash. This results in a ...
MAX868 Regulated, Adjustable -2x Inverting Charge Pump General Description
... The MAX868 inverting charge pump uses pulsefrequency-modulation (PFM) control to generate a regulated negative output voltage up to -2 x V IN. PFM operation is obtained by enabling the internal 450kHz oscillator as needed to maintain output voltage regulation. This control scheme reduces supply curr ...
... The MAX868 inverting charge pump uses pulsefrequency-modulation (PFM) control to generate a regulated negative output voltage up to -2 x V IN. PFM operation is obtained by enabling the internal 450kHz oscillator as needed to maintain output voltage regulation. This control scheme reduces supply curr ...
Chapter 8 Electrical Power 8.1 Introduction
... (Reference 8.2-201) The base case for this analysis represented the expected system configuration and loading in 2017 and included planned transmission projects that had budgetary approval at the time the analysis was performed. The sub-transmission system used for the analysis represented the summe ...
... (Reference 8.2-201) The base case for this analysis represented the expected system configuration and loading in 2017 and included planned transmission projects that had budgetary approval at the time the analysis was performed. The sub-transmission system used for the analysis represented the summe ...
Ω MAX4721/MAX4722/MAX4723 4.5 Dual SPST Analog Switches in UCSP
... Note 2: This device is constructed using a unique set of packaging techniques that impose a limit on the thermal profile the device can be exposed to during board level solder attach and rework. This limit permits only the use of the solder profiles recommended in the industry standard specification ...
... Note 2: This device is constructed using a unique set of packaging techniques that impose a limit on the thermal profile the device can be exposed to during board level solder attach and rework. This limit permits only the use of the solder profiles recommended in the industry standard specification ...
CN-0273 (Rev.B)
... The circuit can be easily evaluated using a signal generator and an oscilloscope. The board is tested with traditional amplifier test methods using a network analyzer. For complete schematics and PCB layout, refer to the CN0273-Design Support package. A photo of the board is shown in Figure 7. ...
... The circuit can be easily evaluated using a signal generator and an oscilloscope. The board is tested with traditional amplifier test methods using a network analyzer. For complete schematics and PCB layout, refer to the CN0273-Design Support package. A photo of the board is shown in Figure 7. ...
First Trans-Rupter II Transformer Protector Installation in Brazil
... With limited monetary resources available, one regional electrical utility, Companhia Energética de Minas Gerais (CEMIG), sought ways to save on the purchased and installed costs of equipment. They turned to S&C Brasil for suggestions. ...
... With limited monetary resources available, one regional electrical utility, Companhia Energética de Minas Gerais (CEMIG), sought ways to save on the purchased and installed costs of equipment. They turned to S&C Brasil for suggestions. ...
Comparison of Multi-Area Load Frequency Control by PI
... al., 2004] has been proposed for AGC. For designing controllers based on these techniques, the perfect model is required which has to track the state variables and satisfy system constraints. Therefore it is difficult to apply these adaptive control techniques to AGC in practical implementations. In ...
... al., 2004] has been proposed for AGC. For designing controllers based on these techniques, the perfect model is required which has to track the state variables and satisfy system constraints. Therefore it is difficult to apply these adaptive control techniques to AGC in practical implementations. In ...
Module 3: Vacuum Fluorescent Displays
... phosphor and electrodes (high power efficiency and dissipate heat generated). A successful VFD for heads-up display / HUD applications was demonstrated with 35 x 103 with a 3000 hour lifetime. The VFD HUD implemented rare earth oxide dopants to the electron emitting material for the oxide cathode an ...
... phosphor and electrodes (high power efficiency and dissipate heat generated). A successful VFD for heads-up display / HUD applications was demonstrated with 35 x 103 with a 3000 hour lifetime. The VFD HUD implemented rare earth oxide dopants to the electron emitting material for the oxide cathode an ...
Tuning the P700VC in Sens Vector and FVC
... the correct motor flux and stator resistance. This will ensure higher starting torque and better performance at low speed operation. An improperly tuned drive can cause the motor to exhibit instability at low speeds, uneven performance load vs. unloaded through the motors speed range and generate un ...
... the correct motor flux and stator resistance. This will ensure higher starting torque and better performance at low speed operation. An improperly tuned drive can cause the motor to exhibit instability at low speeds, uneven performance load vs. unloaded through the motors speed range and generate un ...
VCXO AND HDTV SET-TOP CLOCK SOURCE MK3771
... 2 x (centering error)/(trim sensitivity) Trim sensitivity is a parameter which can be supplied by your ...
... 2 x (centering error)/(trim sensitivity) Trim sensitivity is a parameter which can be supplied by your ...
SCON-CA/CAL/CGAL/CB/CGB First Step Guide Seventh Edition
... Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to this First Step Guide to ensure correct use. This Instruction Manual is original. Warning : Operation of this equipment requires detailed installation and operation instructions which ar ...
... Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to this First Step Guide to ensure correct use. This Instruction Manual is original. Warning : Operation of this equipment requires detailed installation and operation instructions which ar ...
Transistor–transistor logic (TTL) is a class of digital circuits built from
... emitter and collector regions switch roles. Since most BJTs are designed to maximize current gain in forward-active mode, the βf in inverted mode is several times smaller. This transistor mode is seldom used. The reverse bias breakdown voltage to the base may be an order of magnitude lower in this r ...
... emitter and collector regions switch roles. Since most BJTs are designed to maximize current gain in forward-active mode, the βf in inverted mode is several times smaller. This transistor mode is seldom used. The reverse bias breakdown voltage to the base may be an order of magnitude lower in this r ...
Fault Analysis In Transmission System Using Matlab
... short circuit studies i.e., fault analysis and stability studies. The load flow studies are very important for planning the future expansion of the power system as well as determining its best operating conditions. The informations usually obtained from the load flow studies are the magnitude and ph ...
... short circuit studies i.e., fault analysis and stability studies. The load flow studies are very important for planning the future expansion of the power system as well as determining its best operating conditions. The informations usually obtained from the load flow studies are the magnitude and ph ...
AN-727 APPLICATION NOTE
... system grounds connected to the bus and separated by hundreds or thousands of meters will be at the same potential. Because these grounds are unlikely to be at the same potential, current will flow between these points. This unintended current flow can damage or destroy components. ...
... system grounds connected to the bus and separated by hundreds or thousands of meters will be at the same potential. Because these grounds are unlikely to be at the same potential, current will flow between these points. This unintended current flow can damage or destroy components. ...
Effect of Neutral Grounding Methods on the Earth Fault
... Short circuit faults can occur between phases, or between phases and earth, or both. When the system is grounded by a low resistance or directly (solidly) grounded, the fault current will be very large. The characteristics of earth-fault current depend on the method of neutral point grounding as sho ...
... Short circuit faults can occur between phases, or between phases and earth, or both. When the system is grounded by a low resistance or directly (solidly) grounded, the fault current will be very large. The characteristics of earth-fault current depend on the method of neutral point grounding as sho ...
Standard Products Business Promotion - Renesas e
... © 2010 Renesas Electronics Corporation. All rights reserved. ...
... © 2010 Renesas Electronics Corporation. All rights reserved. ...
36-V, Low-Power, Precision, CMOS, RRIO, Low Offset, Low Input
... over operating free-air temperature range (unless otherwise noted) (1) MIN Supply voltage, VS = (V+) – (V–) ...
... over operating free-air temperature range (unless otherwise noted) (1) MIN Supply voltage, VS = (V+) – (V–) ...
Gas-insulated switchgear up to 420 kV, 63 kA, 5000 A
... insulated design they are also used for measuring purposes and for testing protection relays. In the switchgear type 8DQ1 up to 420 kV, the earthing switches are of a pin-type design. Depending on the switchgear design, they are either incorporated in a common housing with the disconnection switches ...
... insulated design they are also used for measuring purposes and for testing protection relays. In the switchgear type 8DQ1 up to 420 kV, the earthing switches are of a pin-type design. Depending on the switchgear design, they are either incorporated in a common housing with the disconnection switches ...
Hardware - triskelmarine
... We had the data and now we needed a controller to deal with the data and provide a platform to start building algorithms. RS232 communication with the old logger was left in and USB support was added for a new logger. The RS485 interface to the existing current sensors was left in but a new CAN netw ...
... We had the data and now we needed a controller to deal with the data and provide a platform to start building algorithms. RS232 communication with the old logger was left in and USB support was added for a new logger. The RS485 interface to the existing current sensors was left in but a new CAN netw ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.