XOCLCC6EVB Crystal Clock Oscillator Module Evaluation Board User's Manual for NBX
... Figure 4. Split Power Supply Lab Setup for LVPECL Outputs (DO NOT JUMPER DUTGND and SMAGND) ...
... Figure 4. Split Power Supply Lab Setup for LVPECL Outputs (DO NOT JUMPER DUTGND and SMAGND) ...
Magneto Resistive Sensors - Rechner Sensors Australia
... Wiring of the MRS should be routed separately or screened from heavy conductor lines, as in extreme cases inductive peak voltages can destroy the sensors despite the integrated protective circuit. Screened cable or twisted lines are recommended, especially for longer cable runs > 5 m. Direct contro ...
... Wiring of the MRS should be routed separately or screened from heavy conductor lines, as in extreme cases inductive peak voltages can destroy the sensors despite the integrated protective circuit. Screened cable or twisted lines are recommended, especially for longer cable runs > 5 m. Direct contro ...
Large Current Rectifiers - Universidad Técnica Federico Santa María
... currents, the paper discusses the working principles of thyristor phase-controlled rectifiers commonly used in these applications. Chopper–rectifiers using high-current insulated gate bipolar transistors are introduced as an alternative being considered in recent projects. The pulsewidth-modulated c ...
... currents, the paper discusses the working principles of thyristor phase-controlled rectifiers commonly used in these applications. Chopper–rectifiers using high-current insulated gate bipolar transistors are introduced as an alternative being considered in recent projects. The pulsewidth-modulated c ...
IEC Separable Connectors 17.5 kV/24 kV, 630A
... The Chardon T-Body connectors are used to terminate polymeric cable to dead front apparatus such as transformers, switchgear, and other equipment. They can be used at 17.5 kV and 24 kV. They can be used for indoor or outdoor applications, and can be used for all polymeric cable types (XLPE, EPR, etc ...
... The Chardon T-Body connectors are used to terminate polymeric cable to dead front apparatus such as transformers, switchgear, and other equipment. They can be used at 17.5 kV and 24 kV. They can be used for indoor or outdoor applications, and can be used for all polymeric cable types (XLPE, EPR, etc ...
Smart Ground Test Report Springfield Energy
... This report describes the ground tests and analysis of the Springfield Power Station. The objective of the test and analysis was to evaluate the plant grounding system with respect to safety performance, and transfer voltage to control circuits and if necessary, to recommend grounding design enhance ...
... This report describes the ground tests and analysis of the Springfield Power Station. The objective of the test and analysis was to evaluate the plant grounding system with respect to safety performance, and transfer voltage to control circuits and if necessary, to recommend grounding design enhance ...
A Complete Electrical Hazard Classification
... contact by skin. This paper and the thresholds discussed are NOT meant to cover electrical injury and thresholds from internally delivered electric shocks, such as can occur under medical procedures, and from internally placed electrical devices. For instance, the threshold of ventricular fibrillati ...
... contact by skin. This paper and the thresholds discussed are NOT meant to cover electrical injury and thresholds from internally delivered electric shocks, such as can occur under medical procedures, and from internally placed electrical devices. For instance, the threshold of ventricular fibrillati ...
MM74C925 * MM74C926 4-Digit Counters with Multiplexed 7
... Segment resistors are desirable to minimize power dissipation and chip heating. The DS75492 serves as a good digit driver when it is desired to drive bright displays. When using this driver with a 5V supply at room temperature, the display can be driven without segment resistors to full illumination ...
... Segment resistors are desirable to minimize power dissipation and chip heating. The DS75492 serves as a good digit driver when it is desired to drive bright displays. When using this driver with a 5V supply at room temperature, the display can be driven without segment resistors to full illumination ...
Power Efficiency of Multiple Clock, Multiple Voltage Cores
... designs compared to synchronous designs. However, their work targets a regular ASIC design flow with simpler clocking strategies rather than the aggressive clock distribution networks used in microprocessors. Of great importance in GALS designs is the choice of the asynchronous communication mechani ...
... designs compared to synchronous designs. However, their work targets a regular ASIC design flow with simpler clocking strategies rather than the aggressive clock distribution networks used in microprocessors. Of great importance in GALS designs is the choice of the asynchronous communication mechani ...
Balance and Single line to ground fault location in electrical
... Various fault location techniques have been developed to assist power system engineers in locating fault fast. By detecting fault fast, the correct faulted section could be isolated and therefore minimize restoration time. The restoration can be expedited if the location of the fault is either known ...
... Various fault location techniques have been developed to assist power system engineers in locating fault fast. By detecting fault fast, the correct faulted section could be isolated and therefore minimize restoration time. The restoration can be expedited if the location of the fault is either known ...
HMC1097LP4E 数据资料DataSheet下载
... performance. It is not recommended to leave the baseband inputs floating which generates excessive current flow that may cause damage to the IC. The baseband inputs should be pulled down to GND in shutdown mode. The nominal baseband input AC Voltage used in the characterization of the HMC1097LP4E is ...
... performance. It is not recommended to leave the baseband inputs floating which generates excessive current flow that may cause damage to the IC. The baseband inputs should be pulled down to GND in shutdown mode. The nominal baseband input AC Voltage used in the characterization of the HMC1097LP4E is ...
Electrical Safety - St. Olaf College
... Departments are expected to maintain safe and healthy living, learning and working environments for faculty, staff, students and visitors to our campus. Departments are expected to assure that all staff, faculty and students are thoroughly familiar with their safety responsibilities and that safety ...
... Departments are expected to maintain safe and healthy living, learning and working environments for faculty, staff, students and visitors to our campus. Departments are expected to assure that all staff, faculty and students are thoroughly familiar with their safety responsibilities and that safety ...
Observations on the Use of Powered Paint Stripping Equipment
... Good technique is required to keep dust from escaping Even using perfect technique, some dust always escapes ...
... Good technique is required to keep dust from escaping Even using perfect technique, some dust always escapes ...
MAX7049EVKIT-433, MAX7049EVKIT-868, MAX7049EVKIT-915
... verify that the light is green. Verify that the TX Ready light is also green. The spectrum analyzer should display an unmodulated carrier at the logic 0 (Space) frequency, which is about 867.95MHz for the 100kHz deviation example. This frequency may be off by up to a few tens of kHz, depending on th ...
... verify that the light is green. Verify that the TX Ready light is also green. The spectrum analyzer should display an unmodulated carrier at the logic 0 (Space) frequency, which is about 867.95MHz for the 100kHz deviation example. This frequency may be off by up to a few tens of kHz, depending on th ...
ZXLD1350 30V 350mA LED DRIVER with AEC-Q100 Description
... The ZXLD1350 has been qualified to AECQ100 grade 2 allowing it to operate at ambient temperatures from -40 to 105°C. ...
... The ZXLD1350 has been qualified to AECQ100 grade 2 allowing it to operate at ambient temperatures from -40 to 105°C. ...
4.3 Setting the Temperature
... Do not touch surfaces that become hot during high temperature operation. Ensure that the operating temperature is less than the maximum operating temperature of your sample material. Ensure that the power switch is easily accessible during use. If liquid is spilled inside the unit, disconnect it fro ...
... Do not touch surfaces that become hot during high temperature operation. Ensure that the operating temperature is less than the maximum operating temperature of your sample material. Ensure that the power switch is easily accessible during use. If liquid is spilled inside the unit, disconnect it fro ...
Evaluation of Power Transistors Figure of Merit for Hard
... necessary to consider also gate drive loss KGS (5). This part becomes very important when veryhigh frequency operation is considered. Input values for calculation of detailed FoM as well as for calculation of KGS listed in Table 2. Consequently the evaluation of FOM was made parametrically, i.e., in ...
... necessary to consider also gate drive loss KGS (5). This part becomes very important when veryhigh frequency operation is considered. Input values for calculation of detailed FoM as well as for calculation of KGS listed in Table 2. Consequently the evaluation of FOM was made parametrically, i.e., in ...
LM2595 SIMPLE SWITCHER Power Converter 150 kHz 1A Step
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
Operational Amplifiers: Basics and Design Aspects
... Figure 8. Gain and open/closed loops [2] The feedback is either negative or positive, but usually negative feedback is used. Positive feedback occurs when some of the output feeds the input in a way that boosts the input value. Negative feedback exists when some of the output returns to the input, b ...
... Figure 8. Gain and open/closed loops [2] The feedback is either negative or positive, but usually negative feedback is used. Positive feedback occurs when some of the output feeds the input in a way that boosts the input value. Negative feedback exists when some of the output returns to the input, b ...
Instantaneous Reclosing
... • Some claim this is the best way to interconnect DG – Same way as nearly all central station generation is connected – However, most utilities don’t allow this connection on their system. ...
... • Some claim this is the best way to interconnect DG – Same way as nearly all central station generation is connected – However, most utilities don’t allow this connection on their system. ...
VOD223T - Vishay
... typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in ...
... typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.