• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
No Slide Title
No Slide Title

... Circuit analysis tells us that each resister should drop 30 V. Using a 20-kW/V meter on the 50-V range, the voltages are much lower than expected. The 1 MW of Rmeter in parallel with 1 MW gives an equivalent resistance of 0.5 MW in series with 1 MW. The meter-resister combination drops only 20 V. Th ...
DAC-HF - DATEL
DAC-HF - DATEL

... from the analog output. Avoid ground loop problems by connecting all grounds on the board to the ground plane. The remainder of the ground plane should include as much of the circuit board as possible. 3. When the converter is configured for voltage output with an external operational amplifier, kee ...
A Generic Architecture for Wafer-Scale Neuromorphic Systems
A Generic Architecture for Wafer-Scale Neuromorphic Systems

... increased from zero to 15. the output current is increased from 10 to 15 10 , Once the output current has reached 1510 , the other MDAC can be incremented to provide an additional 15 10 , doubling the output current in I-bit steps and. therefore, providing an extra bit of precision. And the same pri ...
Impact of high WPPs penetration on the Vietnam Power System Vijay Vittal
Impact of high WPPs penetration on the Vietnam Power System Vijay Vittal

... 0.8 p.u. Moreover, WPPs with voltage dips between 0.65 p.u. and 0.7 p.u. contribute 41% of all WPPs’ generated power which is equal to 412 MW. Whereas, 42% of generated power is from WPPs with voltage dips higher than 0.9 p.u. (or no voltage dip) in Case 2. The respective number for Case 3 is 54%. T ...
SAM Series Power Inverter
SAM Series Power Inverter

... multiply by the AC volts (115) to determine the wattage). The inverter will shut down if it is overloaded. The overload must be removed before the inverter will restart. Resistive loads are the easiest for the inverter to run. However, larger resistive loads, such as electric stoves or heaters, usua ...
Using the AEA 20/20 TDR
Using the AEA 20/20 TDR

DATA  SHEET UDA1334ATS Low power audio DAC with PLL
DATA SHEET UDA1334ATS Low power audio DAC with PLL

... sensitivity is achieved. No post filter is needed due to the inherent filter function of the DAC. On-board amplifiers convert the FSDAC output current to an output voltage signal capable of driving a line output. ...
MAX4490/MAX4491/MAX4492 Low-Cost, High-Slew-Rate, Rail-to-Rail I/O Op Amps in SC70 General Description
MAX4490/MAX4491/MAX4492 Low-Cost, High-Slew-Rate, Rail-to-Rail I/O Op Amps in SC70 General Description

... low-cost CMOS op amps feature Rail-to-Rail® input and output capability from either a single 2.7V to 5.5V supply or dual ±1.35V to ±2.75V supplies. These amplifiers exhibit a high slew rate of 10V/µs and a gain-bandwidth product of 10MHz. They can drive 2kΩ resistive loads to within 55mV of either s ...
Introduction to Piezoelectric Pressure Sensors
Introduction to Piezoelectric Pressure Sensors

... USA ...
MAX14984 Enhanced VGA Port Protector with Monitor General Description
MAX14984 Enhanced VGA Port Protector with Monitor General Description

... monitor is detected. A switched 5V output provides up to 55mA to the VGA port in addition to normal VGA signals. The MAX14984 features a single active-low enable input to control two 5V USB switches. Each switch supplies 500mA of current with less than 250mV drop from VCC, and is protected against s ...
ECE137A Notes Set 1: Bipolar Transistors Characteristics
ECE137A Notes Set 1: Bipolar Transistors Characteristics

... page 10 ...
FSUSB104 — Low-Power, Two-Port, Hi-Speed, USB2.0 (480Mbps) Switch FSU S
FSUSB104 — Low-Power, Two-Port, Hi-Speed, USB2.0 (480Mbps) Switch FSU S

AC bias characterization of low noise bolometers for SAFARI using
AC bias characterization of low noise bolometers for SAFARI using

... carbon loaded epoxy. The circuit PC board is designed to host 2 DC and 18 AC bias channels. The latter is achieved by using the lithografic high-Q LC resonators arrays developed at SRON 2 . The nominal inductance of the coil used in each filter is L = 400nH, while the capacitances C are designed suc ...
Chapter 6 - AutomationDirect
Chapter 6 - AutomationDirect

... Modern AC drives are based on solid state electronics technology. Preventive maintenance is required to operate the AC drive in its optimal condition, and to ensure a long life. We recommend that a qualified technician perform a regular inspection of the AC drive. Some items should be checked once a ...
1.2 Ideal Op-Amp
1.2 Ideal Op-Amp

... Ideally, output of an op-amp is 0 Volt if the input is 0 Volt. Realistically, a small dc voltage will appear at the output when no input voltage is applied. Thus, differential dc voltage is required between the inputs to force the output to zero volts. This is called the Input Offset Voltage, Vos. R ...
Parallel Charging Using Multiple Controllers With Separate PV Arrays
Parallel Charging Using Multiple Controllers With Separate PV Arrays

... complete absorption charging, this does not necessarily indicate that there is a problem. At the end of an absorption charging state, it should not take much current to maintain absorption regulation voltage, so it may indicate that the batteries are not fully charged and additional charging may be ...
Power Management Reference Design for a
Power Management Reference Design for a

... While the bq25120 integrates a single, ultra-low power step-down converter for one rail, some systems, such as an MCU, radio or sensor, need a second high-efficiency rail with a different voltage. For these sub-systems, a discrete ultra-low power step-down converter with similar performance to the b ...
New design techniques for a complementary metal
New design techniques for a complementary metal

AN347
AN347

... protecting TMDS signal lines, it is recommended to pick an ESD protection device with 5A peak pulse current at 125W peak pulse power. As the ESD protection devices are added between TMDS outputs of PI3HDMI201/301 and HDMI connector of an HDMI source device, the implementation of ESD protection devic ...
LEEP 1000 Workstation Operating Manual, 110v
LEEP 1000 Workstation Operating Manual, 110v

... 2. Replacement accessories and patient return pads should be kept on hand since defective active accessory or patient return pads can result in substandard performance of this equipment. 3. This equipment should only be connected to a properly grounded receptacle. NEVER use an adapter that defeats t ...
Panasonic KR20 High-Speed Wireless Unit
Panasonic KR20 High-Speed Wireless Unit

ABB circuit-breakers for direct current applications
ABB circuit-breakers for direct current applications

USER MANUAL VU01 Hukseflux
USER MANUAL VU01 Hukseflux

RouterBOARD 111/112 Series
RouterBOARD 111/112 Series

FAULT DIAGNOSIS AND DETECTION IN POWER SYSTEMS
FAULT DIAGNOSIS AND DETECTION IN POWER SYSTEMS

... better voltage profile and quality power to consumers. We introduce a neural network in the power system, which can learn and therefore be trained to find solutions, recognize patterns, classify data and forecast future events. In general, we use a control methodology in Artificial Neural Network (A ...
< 1 ... 503 504 505 506 507 508 509 510 511 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report