Click here
... FIGURE 20-23 General Motors CS generator. Notice the use of zener diodes in the rectifier to help control any high-voltage surges that could affect delicate computer circuits. If a high-voltage surge does occur, the zener diode(s) will be reverse biased and the potentially harmful voltage will be s ...
... FIGURE 20-23 General Motors CS generator. Notice the use of zener diodes in the rectifier to help control any high-voltage surges that could affect delicate computer circuits. If a high-voltage surge does occur, the zener diode(s) will be reverse biased and the potentially harmful voltage will be s ...
AN-1876 LM2841 Evaluation Board (Rev. C)
... The LM2841 is a PWM DC/DC buck (step-down) regulator. With a wide input range from 4.5V-42V, it is suitable for a wide range of applications from automotive to power conditioning from unregulated sources. The LM2841 evaluation board is designed to provide the design engineer with a fully functional ...
... The LM2841 is a PWM DC/DC buck (step-down) regulator. With a wide input range from 4.5V-42V, it is suitable for a wide range of applications from automotive to power conditioning from unregulated sources. The LM2841 evaluation board is designed to provide the design engineer with a fully functional ...
Manual 900 MHz
... carried by the crane operator. Belt clips and shoulder harness are provided to enable the operator to conveniently carry the unit while leaving hands free to operate controls. Switches on the transmitter control all functions of the crane. The portable transmitter weight is 5.2 pounds or less. The t ...
... carried by the crane operator. Belt clips and shoulder harness are provided to enable the operator to conveniently carry the unit while leaving hands free to operate controls. Switches on the transmitter control all functions of the crane. The portable transmitter weight is 5.2 pounds or less. The t ...
File - Electrical Technology
... An attempt by the temperature to increase and shift the collector current (IC) and the operating point respectively will experience a self feedback situation to correct this unwanted change. If the collector current (IC) tries to increase due to an increase in temperature will cause the emitter curr ...
... An attempt by the temperature to increase and shift the collector current (IC) and the operating point respectively will experience a self feedback situation to correct this unwanted change. If the collector current (IC) tries to increase due to an increase in temperature will cause the emitter curr ...
Proposal for Battery Facilities Technical and Operating Requirements Work Group Session
... Battery Facilities – Work Group – Nov 20th, 2013 ...
... Battery Facilities – Work Group – Nov 20th, 2013 ...
ADG719 数据手册DataSheet下载
... that will be produced. TPC 7 illustrates the drop in off isolation as a function of frequency. From dc to roughly 200 kHz, the switch shows better than –95 dB isolation. Up to frequencies of 10 MHz, the off isolation remains better than –67 dB. As the frequency increases, more and more of the input ...
... that will be produced. TPC 7 illustrates the drop in off isolation as a function of frequency. From dc to roughly 200 kHz, the switch shows better than –95 dB isolation. Up to frequencies of 10 MHz, the off isolation remains better than –67 dB. As the frequency increases, more and more of the input ...
MAX14579E/MAX14579AE Low-Power Headset Detectors with SEND/END Button Support General Description
... VBIAS (typ)) for longer than the debounce time (typ). The SWD output is logic-low for the duration of the SEND/ END button press event following the debounce period. The SEND/END detection circuitry is active whenever a jack is inserted. The debounce period built into the SEND/END button press detec ...
... VBIAS (typ)) for longer than the debounce time (typ). The SWD output is logic-low for the duration of the SEND/ END button press event following the debounce period. The SEND/END detection circuitry is active whenever a jack is inserted. The debounce period built into the SEND/END button press detec ...
Can Water Store Charge? - University of Washington
... V charging voltage; 1 h charging time; 10 kΩ load resistance. 10 mM NaCl electrolyte. (a) Initial 10 s from beginning of discharge; (b) full extent of discharge, up to 30 min. ...
... V charging voltage; 1 h charging time; 10 kΩ load resistance. 10 mM NaCl electrolyte. (a) Initial 10 s from beginning of discharge; (b) full extent of discharge, up to 30 min. ...
S285-60-1
... Type PST-9 Automatic Source Transfer Switchgear provides both loss-of-voltage and overcurrent protection for critical loads for 15-, 25-, and 35 kV underground systems. PST-9 units are self-contained, steel constructed pad mount enclosures containing oil as a dielectric insulator medium. They are sh ...
... Type PST-9 Automatic Source Transfer Switchgear provides both loss-of-voltage and overcurrent protection for critical loads for 15-, 25-, and 35 kV underground systems. PST-9 units are self-contained, steel constructed pad mount enclosures containing oil as a dielectric insulator medium. They are sh ...
MT-038: Op Amp Input Bias Current
... currents of a bias-compensated op amp may not only be mismatched, they can actually flow in opposite directions! In most applications this isn't important, but in some it can have unexpected effects (for example the droop of a sample-and-hold (SHA) built with a bias-compensated op amp may have eithe ...
... currents of a bias-compensated op amp may not only be mismatched, they can actually flow in opposite directions! In most applications this isn't important, but in some it can have unexpected effects (for example the droop of a sample-and-hold (SHA) built with a bias-compensated op amp may have eithe ...
Short-Circuit/Coordination Study and Arc Flash Hazard Study
... all directly affected existing distribution equipment at the District's facility. The study shall include all portions of the existing and proposed electrical distribution system from the electric utility power source(s) and emergency power source(s) down to and including each switchboard, distribut ...
... all directly affected existing distribution equipment at the District's facility. The study shall include all portions of the existing and proposed electrical distribution system from the electric utility power source(s) and emergency power source(s) down to and including each switchboard, distribut ...
FDMF6705V - Extra-Small, High-Performance, High- Frequency DrMOS Module FDMF6705V - Extra-S m
... With an integrated approach, the complete switching power stage is optimized with regards to driver and MOSFET dynamic performance, system inductance, and Power MOSFET RDS(ON). XS™ DrMOS uses Fairchild's high-performance PowerTrench® MOSFET technology, which dramatically reduces switch ringing, elim ...
... With an integrated approach, the complete switching power stage is optimized with regards to driver and MOSFET dynamic performance, system inductance, and Power MOSFET RDS(ON). XS™ DrMOS uses Fairchild's high-performance PowerTrench® MOSFET technology, which dramatically reduces switch ringing, elim ...
Instruction Manual for FrSky Two-Way System
... FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. ...
... FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. ...
SP485R 数据资料DataSheet下载
... LOW to DE and a logic HIGH to RE. While in the shutdown mode, the power supply current is typically less than 1µA. The driver outputs are disabled and are at a high impedance state determined by the receiver input impedance which should be at least 120kΩ. The receiver output is at also at high imped ...
... LOW to DE and a logic HIGH to RE. While in the shutdown mode, the power supply current is typically less than 1µA. The driver outputs are disabled and are at a high impedance state determined by the receiver input impedance which should be at least 120kΩ. The receiver output is at also at high imped ...
Backlight Driver for 5 LEDs with Charge Pump and PWM Control
... in 1.5x and 2x modes and is disabled in 1x mode to save power and improve efficiency. The mode selection circuit automatically selects the mode as 1x, 1.5x, or 2x based on circuit conditions such as LED voltage, input voltage, and load current. The 1x mode is the most efficient of the three modes, f ...
... in 1.5x and 2x modes and is disabled in 1x mode to save power and improve efficiency. The mode selection circuit automatically selects the mode as 1x, 1.5x, or 2x based on circuit conditions such as LED voltage, input voltage, and load current. The 1x mode is the most efficient of the three modes, f ...
Homemade VHF and UHF Antennas
... back toward the radio from the antenna When using this method you will need to announce your call sign when testing, and stay 5 KHz inside the ham bands ...
... back toward the radio from the antenna When using this method you will need to announce your call sign when testing, and stay 5 KHz inside the ham bands ...
IAR Embedded Workbench ® IAR Debugging probes User Guide
... (MIPI-20 or MIPI-10). If a standard JTAG connector is used, you must first plug the JTAG-20 to MIPI-20 adapter into the JTAG connector. Note: No harm is done if the above order is reversed. To prevent damage, the target GND and the USB host GND must be at the same level. When hot-plugging, make sure ...
... (MIPI-20 or MIPI-10). If a standard JTAG connector is used, you must first plug the JTAG-20 to MIPI-20 adapter into the JTAG connector. Note: No harm is done if the above order is reversed. To prevent damage, the target GND and the USB host GND must be at the same level. When hot-plugging, make sure ...
LTM4616 - Dual 8A per Channel Low VIN DC/DC uModule
... two outputs within a voltage range of 0.6V to 5V, each set by a single external resistor. This high efficiency design delivers up to 8A continuous current (10A peak) for each output. Only bulk input and output capacitors are needed, depending on ripple requirement. The part can also be configured fo ...
... two outputs within a voltage range of 0.6V to 5V, each set by a single external resistor. This high efficiency design delivers up to 8A continuous current (10A peak) for each output. Only bulk input and output capacitors are needed, depending on ripple requirement. The part can also be configured fo ...
Considerations when buying a corona treater - Webconvert-ltd
... “sized” based on the application, and is related to line conditions. The formula used to specify a generator size is as follows; Line speed x Web Width x # of sides to be treated x Power factor The power factor is the watt density required in order to obtain adequate treatment, and is the result of ...
... “sized” based on the application, and is related to line conditions. The formula used to specify a generator size is as follows; Line speed x Web Width x # of sides to be treated x Power factor The power factor is the watt density required in order to obtain adequate treatment, and is the result of ...
AD688 数据手册DataSheet 下载
... +10 V Output with Kelvin Sense. Connect to Pin 1. + Input to A3. Connect to VHIGH, Pin 6. Reference Gain Adjustment for Calibration. See the Calibration section. Unbuffered Reference High Output. Noise Filtering Pin. Connect external 1 µF capacitor to ground to reduce output noise, see the Noise Per ...
... +10 V Output with Kelvin Sense. Connect to Pin 1. + Input to A3. Connect to VHIGH, Pin 6. Reference Gain Adjustment for Calibration. See the Calibration section. Unbuffered Reference High Output. Noise Filtering Pin. Connect external 1 µF capacitor to ground to reduce output noise, see the Noise Per ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.