Smart Power Switch - Texas Instruments
... The power interrupt normal operation consists of the chip turning the driver immediately back on if the interrupt goes away prior to CDEL reaching its lower threshold as described above. The CDEL capacitor is chosen based upon the maximum power interrupt time (tINT) allowed without the output experi ...
... The power interrupt normal operation consists of the chip turning the driver immediately back on if the interrupt goes away prior to CDEL reaching its lower threshold as described above. The CDEL capacitor is chosen based upon the maximum power interrupt time (tINT) allowed without the output experi ...
30XW-V/30XWHV Variable-Speed Water-Cooled Liquid - TZB-info
... drawings supplied with the unit. Do not tilt the unit more than 15°. Safety is only guaranteed, if these instructions are carefully followed. If this is not the case, there is a risk of material deterioration and injuries to personnel. Never cover any protection devices. ...
... drawings supplied with the unit. Do not tilt the unit more than 15°. Safety is only guaranteed, if these instructions are carefully followed. If this is not the case, there is a risk of material deterioration and injuries to personnel. Never cover any protection devices. ...
MP6507 - Monolithic Power System
... with dual, built-in full-bridges consisting of Nchannel power MOSFETs. It operates from a supply voltage range of 2.7V to 15V, and can deliver motor current up to 700mA per channel. The internal safety features include sinking and sourcing current limits implemented with external sensors, under-volt ...
... with dual, built-in full-bridges consisting of Nchannel power MOSFETs. It operates from a supply voltage range of 2.7V to 15V, and can deliver motor current up to 700mA per channel. The internal safety features include sinking and sourcing current limits implemented with external sensors, under-volt ...
Tuning your oneTesla
... circuit, and the IGBT bridge in particular, was designed for an interrupted Tesla coil, and the components are not rated to handle continuous operation at full mains voltage. If you were to try continous operation, the current in the primary coil would become too high and fry the IGBTs within millis ...
... circuit, and the IGBT bridge in particular, was designed for an interrupted Tesla coil, and the components are not rated to handle continuous operation at full mains voltage. If you were to try continous operation, the current in the primary coil would become too high and fry the IGBTs within millis ...
MAX16813 Evaluation Kit Evaluates: MAX16813 General Description Features
... The MAX16813 EV kit demonstrates the MAX16813 HB LED driver with an integrated step-up DC-DC preregulator followed by 4 channels of linear current sinks. The preregulator switches at 350kHz and operates as a currentmode-controlled regulator providing up to 600mA for the linear circuit while providin ...
... The MAX16813 EV kit demonstrates the MAX16813 HB LED driver with an integrated step-up DC-DC preregulator followed by 4 channels of linear current sinks. The preregulator switches at 350kHz and operates as a currentmode-controlled regulator providing up to 600mA for the linear circuit while providin ...
Datasheet - Mouser Electronics
... The LN CSAC provides a 10 MHz sine wave output and 1 PPS output, with short-term stability [Allan Deviation] of ≤2E-11 @ TAU = 1 sec, long–term aging of ≤9E-10/month, and maximum frequency change of ±5E-10 over an operating temperature range of –10°C to +35°C. ...
... The LN CSAC provides a 10 MHz sine wave output and 1 PPS output, with short-term stability [Allan Deviation] of ≤2E-11 @ TAU = 1 sec, long–term aging of ≤9E-10/month, and maximum frequency change of ±5E-10 over an operating temperature range of –10°C to +35°C. ...
The Secrets of UL and NFPA. - Automation Technology
... is generally made between factory wiring (sometimes also called internal wiring) and field wiring. Factory wiring is understood to be wiring that is laid and connected only in the control panel (i.e. under supervision), while field wiring is wiring that is connected by an electrician “in the field”. ...
... is generally made between factory wiring (sometimes also called internal wiring) and field wiring. Factory wiring is understood to be wiring that is laid and connected only in the control panel (i.e. under supervision), while field wiring is wiring that is connected by an electrician “in the field”. ...
1100B Technical Specifications - Mitsubishi Electric Power Products
... following specifications for which MEPPI has not approved or authorized such modifications. Further, MEPPI shall not be liable for any special, incidental, indirect, punitive or consequential damages arising out of or in connection with the use of such specifications. Copyright © 2008, Mitsubishi El ...
... following specifications for which MEPPI has not approved or authorized such modifications. Further, MEPPI shall not be liable for any special, incidental, indirect, punitive or consequential damages arising out of or in connection with the use of such specifications. Copyright © 2008, Mitsubishi El ...
PAM8603A
... 2. When the PAM8603A works without LC filters, it's better to add a ferrite chip bead at the outgoing line of speaker for suppressing the possible electromagnetic interference. 3. The absolute maximum rating of the PAM8603A operation voltage is 6V. When the PAM8603A is powered with four battery cell ...
... 2. When the PAM8603A works without LC filters, it's better to add a ferrite chip bead at the outgoing line of speaker for suppressing the possible electromagnetic interference. 3. The absolute maximum rating of the PAM8603A operation voltage is 6V. When the PAM8603A is powered with four battery cell ...
Section 3: Switching Regulators
... basic power converter topology, these ICs are called “switching regulators”. When no switches are included in the IC, but the signal for driving an external switch is provided, it is called a “switching regulator controller”. Sometimes - usually for higher power levels - the control is not entirely ...
... basic power converter topology, these ICs are called “switching regulators”. When no switches are included in the IC, but the signal for driving an external switch is provided, it is called a “switching regulator controller”. Sometimes - usually for higher power levels - the control is not entirely ...
Multisim Electronics Workbench Tutorial
... With the components in place you are ready to connect the wires. Workbench has no wire mode. You connect wires by moving the cursor to a component wire end, click on it, go to a second component and click on its wire end. Workbench will then fill in a wire between those two components. If you get a ...
... With the components in place you are ready to connect the wires. Workbench has no wire mode. You connect wires by moving the cursor to a component wire end, click on it, go to a second component and click on its wire end. Workbench will then fill in a wire between those two components. If you get a ...
Motor control
... MCU uses normal output voltage – gate driver ups to match gate MCU is on isolated power circuit to avoid noise issues Short circuit protection – maybe MCU algorithm should prevent turning on high/low same side Dead-time for shoot-through protection MCU or Gate drivers needs to allow for ...
... MCU uses normal output voltage – gate driver ups to match gate MCU is on isolated power circuit to avoid noise issues Short circuit protection – maybe MCU algorithm should prevent turning on high/low same side Dead-time for shoot-through protection MCU or Gate drivers needs to allow for ...
G48033641
... It is a challenging task for a VLSI design engineer to develop low power VLSI circuits, without sacrificing its performance. Feedthrough Logic (FTL) is a new technology which could be considered better than the existing technologies for improving circuit efficiency. Modified Feedthrough Logic (MFTL) ...
... It is a challenging task for a VLSI design engineer to develop low power VLSI circuits, without sacrificing its performance. Feedthrough Logic (FTL) is a new technology which could be considered better than the existing technologies for improving circuit efficiency. Modified Feedthrough Logic (MFTL) ...
Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and
... Table 1: Comparison of requirements for EEx i and EEx n In practical terms, the reduction in safety factor means that the output from a Zone 2 power supply, for example, can go closer to the point of ignition on the ignition curves than an intrinsically safe supply. It can therefore deliver more pow ...
... Table 1: Comparison of requirements for EEx i and EEx n In practical terms, the reduction in safety factor means that the output from a Zone 2 power supply, for example, can go closer to the point of ignition on the ignition curves than an intrinsically safe supply. It can therefore deliver more pow ...
Fuji Electric PXR3 Temperature Controller Brochure
... Absolute alarm, deviation alarm, zone alarm with upper and lower limits for each Hold function available (see figure below) Alarm latch function provided Delay setting 0 to 9999 sec settable in 1 sec steps Alarm ON-delay Process alarm output Relay contact: SPST contact: 220 V AC/30 V DC, 1 A (resist ...
... Absolute alarm, deviation alarm, zone alarm with upper and lower limits for each Hold function available (see figure below) Alarm latch function provided Delay setting 0 to 9999 sec settable in 1 sec steps Alarm ON-delay Process alarm output Relay contact: SPST contact: 220 V AC/30 V DC, 1 A (resist ...
Installation Instructions
... maximum rating of such a filter is 40 microns to provide adequate protection. 2. Pipe thread sealing compounds and tape must be prevented from entering the valve. 3. New systems must be adequately flushed to remove all pipe scale, weld slag, thread burrs, etc. It is typically necessary to flush new ...
... maximum rating of such a filter is 40 microns to provide adequate protection. 2. Pipe thread sealing compounds and tape must be prevented from entering the valve. 3. New systems must be adequately flushed to remove all pipe scale, weld slag, thread burrs, etc. It is typically necessary to flush new ...
RF6590 POWER MANAGEMENT IC Features
... • SPI logic voltage should not exceed 1.8 volts (Output 2 supply) during operation. • Do not exceed listed currents in CLK mode, otherwise the Output voltage will fall out of regulation. • Register 0 must be restored by the controller, whenever the mode enters TRX mode. All registers should be consi ...
... • SPI logic voltage should not exceed 1.8 volts (Output 2 supply) during operation. • Do not exceed listed currents in CLK mode, otherwise the Output voltage will fall out of regulation. • Register 0 must be restored by the controller, whenever the mode enters TRX mode. All registers should be consi ...
- Electronics
... most difficult branch of electronics. The CD-ROM includes a host of virtual laboratories, animations, diagrams, photographs and text as well as a SPICE electronic circuit simulator with over 50 pre-designed circuits. The component values on all circuits can be edited and the user can use the simulat ...
... most difficult branch of electronics. The CD-ROM includes a host of virtual laboratories, animations, diagrams, photographs and text as well as a SPICE electronic circuit simulator with over 50 pre-designed circuits. The component values on all circuits can be edited and the user can use the simulat ...
731 989USB - LD Didactic
... Always use coupling and shaftend guards to protect against contact to rotating parts. Normally it is not necessary to open the device's housing. However, should this prove necessary, this may only be performed by a technician and only under the condition that the mains plug and all connecting leads ...
... Always use coupling and shaftend guards to protect against contact to rotating parts. Normally it is not necessary to open the device's housing. However, should this prove necessary, this may only be performed by a technician and only under the condition that the mains plug and all connecting leads ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.