2.5MHz, 1.5A Synchronous Step Down Regulator
... an ultra-small 2mm x 2mm, low profile package or a low cost SOT23-5 package. The device requires only three external filter components for a complete step down regulator solution. The input voltage range is 2.9 to 5.5V with either factory programmed outputs from 1.0 to 3.3V or adjustable output via ...
... an ultra-small 2mm x 2mm, low profile package or a low cost SOT23-5 package. The device requires only three external filter components for a complete step down regulator solution. The input voltage range is 2.9 to 5.5V with either factory programmed outputs from 1.0 to 3.3V or adjustable output via ...
UC3825 数据资料 dataSheet 下载
... TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous mater ...
... TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous mater ...
SAMWHA Products
... Main Decoupling MLCC for Industrial Applications SAMWHA high voltage MLCC products with the temperature characteristics of C0G and X7R are designed for commercial and industrial applications. The products are applied to DC-DC converters and ballast circuit to reduce ripple noise and diverting potent ...
... Main Decoupling MLCC for Industrial Applications SAMWHA high voltage MLCC products with the temperature characteristics of C0G and X7R are designed for commercial and industrial applications. The products are applied to DC-DC converters and ballast circuit to reduce ripple noise and diverting potent ...
part 2 products - GE Grid Solutions
... amp-hour rating for those applications requiring faster recharge times. Actual available charge current will still depend on output load level and power factor. ...
... amp-hour rating for those applications requiring faster recharge times. Actual available charge current will still depend on output load level and power factor. ...
MAX127/MAX128 Multirange, +5V, 12-Bit DAS with 2-Wire Serial Interface General Description
... The MAX127/MAX128 are multirange, 12-bit data acquisition systems (DAS) that require only a single +5V supply for operation, yet accept signals at their analog inputs that may span above the power-supply rail and below ground. These systems provide eight analog input channels that are independently ...
... The MAX127/MAX128 are multirange, 12-bit data acquisition systems (DAS) that require only a single +5V supply for operation, yet accept signals at their analog inputs that may span above the power-supply rail and below ground. These systems provide eight analog input channels that are independently ...
CAT5171 - 256‐position I2C Compatible Digital Potentiometer (POT)
... significant six bits of the slave address are a device type identifier. For the CAT5171, these bits are fixed at 010110. The next bit, AD0, is the first bit of the internal slave address and must match the physical device address which is defined by the state of the AD0 input pin for the CAT5171 to ...
... significant six bits of the slave address are a device type identifier. For the CAT5171, these bits are fixed at 010110. The next bit, AD0, is the first bit of the internal slave address and must match the physical device address which is defined by the state of the AD0 input pin for the CAT5171 to ...
DFIG-Steady state
... which induces an emf in the rotor windings according to eind • eind=induced emf in one conductor of rotor • v=velocity of conductor relative to stator flux rotation • B=stator magnetic flux density vector • L=length of conductor in direction of wire ...
... which induces an emf in the rotor windings according to eind • eind=induced emf in one conductor of rotor • v=velocity of conductor relative to stator flux rotation • B=stator magnetic flux density vector • L=length of conductor in direction of wire ...
Guitar Pickup Theory
... The resonant frequency of most available pickups in combination with normal guitar cables lies between 2,000 and 5,000 Hz. This is the range where the human ear has its highest sensitivity. A quick subjective correlation of frequency to sound is that at 2,000 Hz the sound is warm and mellow, at 3,00 ...
... The resonant frequency of most available pickups in combination with normal guitar cables lies between 2,000 and 5,000 Hz. This is the range where the human ear has its highest sensitivity. A quick subjective correlation of frequency to sound is that at 2,000 Hz the sound is warm and mellow, at 3,00 ...
CA320005EN
... overhead distribution lines and derive their power from the voltage gradient between the line and the ground plane. This voltage gradient provides a reliable source for operating and resetting the fault indicator when compared to current reset devices which are subject to system loading variations. ...
... overhead distribution lines and derive their power from the voltage gradient between the line and the ground plane. This voltage gradient provides a reliable source for operating and resetting the fault indicator when compared to current reset devices which are subject to system loading variations. ...
Connection of generation plant to distribution networks
... electrical documentation as proof of the technical information provided in this application form. We will also require details of any existing generation on site ...
... electrical documentation as proof of the technical information provided in this application form. We will also require details of any existing generation on site ...
15170 Elec Motors
... manufacturer’s complying with the provisions of this specification are acceptable. Motors from 1/2 HP through 200 HP shall be 460V, 3-phase, 60 Hz, squirrel cage induction type. It is the responsibility of each manufacturer to thoroughly review the plans and specifications and determine that their e ...
... manufacturer’s complying with the provisions of this specification are acceptable. Motors from 1/2 HP through 200 HP shall be 460V, 3-phase, 60 Hz, squirrel cage induction type. It is the responsibility of each manufacturer to thoroughly review the plans and specifications and determine that their e ...
NB6L14M 2.5 V/3.3 V 3.0 GHz Differential 1:4 CML Fanout Buffer
... to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, ...
... to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, ...
TD-L1630 - skipper
... (3) The frequencies memorized in the memory are maintained with the built-in Nickel Cadmium (Ni-Cd) backup battery. The Ni-Cd battery is automatically re-charged while the power of the main unit is ON. When the equipment is operated for the first time, not operated over one month or replaced the Ni- ...
... (3) The frequencies memorized in the memory are maintained with the built-in Nickel Cadmium (Ni-Cd) backup battery. The Ni-Cd battery is automatically re-charged while the power of the main unit is ON. When the equipment is operated for the first time, not operated over one month or replaced the Ni- ...
electrical installation standards
... In all cases, it must be possible to disconnect the wiring from a piece of equipment without affecting the operation of the remainder of the installation. Bridging of multiple wires in a single end fitting and conductor junctions in wiring ducts are not permitted. The minimum cross-section for the c ...
... In all cases, it must be possible to disconnect the wiring from a piece of equipment without affecting the operation of the remainder of the installation. Bridging of multiple wires in a single end fitting and conductor junctions in wiring ducts are not permitted. The minimum cross-section for the c ...
SECTION [26 12 19] [16271] PAD-MOUNTED, LIQUID
... The windings shall be tightly wound utilizing tension devices to place the conductor into the coils. ...
... The windings shall be tightly wound utilizing tension devices to place the conductor into the coils. ...
Aalborg Universitet Yang, Yongheng; Ma, Ke; Wang, Huai; Blaabjerg, Frede
... into the capacitor stresses, including both electrical and thermal stresses. However, on-line predicting the lifetime of the capacitor (catastrophic failures) are more challenging, which calls for an instantaneous thermal modelling for monitoring and thus protection of the DC-link capacitors. Hence, ...
... into the capacitor stresses, including both electrical and thermal stresses. However, on-line predicting the lifetime of the capacitor (catastrophic failures) are more challenging, which calls for an instantaneous thermal modelling for monitoring and thus protection of the DC-link capacitors. Hence, ...
xbis - International Journal of Engineering and Computer Science
... position because it may have no torque, run in wrong direction, blow its fuse, overheat, or simply not run if wiring is incorrect. Motor start capacitors are used to operate drive roller. Motor: X-ray machine has chain driven rollers powered by three phase motors. The three phase motor is powered by ...
... position because it may have no torque, run in wrong direction, blow its fuse, overheat, or simply not run if wiring is incorrect. Motor start capacitors are used to operate drive roller. Motor: X-ray machine has chain driven rollers powered by three phase motors. The three phase motor is powered by ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.