![74AVCH8T245 1. General description 8-bit dual supply translating transceiver with configurable](http://s1.studyres.com/store/data/008857656_1-2dc8cd165c8e02e0c86f6d8a406d7741-300x300.png)
74AVCH8T245 1. General description 8-bit dual supply translating transceiver with configurable
... 2.5 V and 3.3 V). Pins An, OE and DIR are referenced to VCC(A) and pins Bn are referenced to VCC(B). A HIGH on DIR allows transmission from An to Bn and a LOW on DIR allows transmission from Bn to An. The output enable input (OE) can be used to disable the outputs so the buses are effectively isolat ...
... 2.5 V and 3.3 V). Pins An, OE and DIR are referenced to VCC(A) and pins Bn are referenced to VCC(B). A HIGH on DIR allows transmission from An to Bn and a LOW on DIR allows transmission from Bn to An. The output enable input (OE) can be used to disable the outputs so the buses are effectively isolat ...
Twido programmable controllers
... Electrical equipment should be serviced only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. This document is not intended as an instruction manual for untrained persons. Assembly and installation instructions a ...
... Electrical equipment should be serviced only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. This document is not intended as an instruction manual for untrained persons. Assembly and installation instructions a ...
MAX13046E/MAX13047E Single- and Dual-Bidirectional Low-Level Translator General Description
... dual-channel translator. Externally applied voltages, VCC and VL, set the logic level on either side of the device. The MAX13046E/MAX13047E utilize a transmission-gate-based design to allow data translation in either direction (VL↔VCC) on any single data line. The MAX13046E/MAX13047E accept VL from ...
... dual-channel translator. Externally applied voltages, VCC and VL, set the logic level on either side of the device. The MAX13046E/MAX13047E utilize a transmission-gate-based design to allow data translation in either direction (VL↔VCC) on any single data line. The MAX13046E/MAX13047E accept VL from ...
arduino101_present_20130122
... Based on a simple micro-controller board, and A development environment (IDE) for writing software for the board ...
... Based on a simple micro-controller board, and A development environment (IDE) for writing software for the board ...
SIMATIC ET 200 - Automation Technology
... Each standard product from the SIMATIC range is characterized by the highest quality and robustness and is perfect for use in industrial environments. Specific system tests ensure the planned and required quality. SIMATIC components meet all relevant international standards and are certified accordi ...
... Each standard product from the SIMATIC range is characterized by the highest quality and robustness and is perfect for use in industrial environments. Specific system tests ensure the planned and required quality. SIMATIC components meet all relevant international standards and are certified accordi ...
Technical improvements of Windside wind turbine systems
... This thesis derives from a wind power activity at the University of Vaasa from the beginning of year 2002 to the end of 2013. The participants in the project were Department of Electrical Engineering in University of Vaasa and the manufacturer of studied wind turbine devices, i.e. Oy Windside Produc ...
... This thesis derives from a wind power activity at the University of Vaasa from the beginning of year 2002 to the end of 2013. The participants in the project were Department of Electrical Engineering in University of Vaasa and the manufacturer of studied wind turbine devices, i.e. Oy Windside Produc ...
Model 330 - Lake Shore Cryotronics, Inc.
... Lake Shore certifies that this product has been inspected and tested in accordance with its published specifications and that this product met its published specifications at the time of shipment. The accuracy and calibration of this product at the time of shipment are traceable to the United States ...
... Lake Shore certifies that this product has been inspected and tested in accordance with its published specifications and that this product met its published specifications at the time of shipment. The accuracy and calibration of this product at the time of shipment are traceable to the United States ...
C21 Dimming System
... c.) IGBT dimmers shall not use zero cross detection to synchronize to the power line. Dimmer output voltage shall be unaffected by severely distorted or noisy power line waveforms. d.) IGBT dimmers shall automatically switch from Reverse Phase Control (RPC) mode to Forward Phase Control (FPC) mode ...
... c.) IGBT dimmers shall not use zero cross detection to synchronize to the power line. Dimmer output voltage shall be unaffected by severely distorted or noisy power line waveforms. d.) IGBT dimmers shall automatically switch from Reverse Phase Control (RPC) mode to Forward Phase Control (FPC) mode ...
Comparison of PAM-4 and NRZ Signaling
... PAM-4 will perform better or worse than NRZ based on channel design factors. The results show NRZ performed better for the five backplanes being measured. Backplanes A, B, C, and D passed NRZ with at least 1 aggressor and all of these failed to pass PAM-4 even with 0 aggressors. Backplane C passes N ...
... PAM-4 will perform better or worse than NRZ based on channel design factors. The results show NRZ performed better for the five backplanes being measured. Backplanes A, B, C, and D passed NRZ with at least 1 aggressor and all of these failed to pass PAM-4 even with 0 aggressors. Backplane C passes N ...
KEI 2302, 2306 Service
... Operators use the product for its intended function. They must be trained in electrical safety procedures and proper use of the instrument. They must be protected from electric shock and contact with hazardous live circuits. Maintenance personnel perform routine procedures on the product to keep it ...
... Operators use the product for its intended function. They must be trained in electrical safety procedures and proper use of the instrument. They must be protected from electric shock and contact with hazardous live circuits. Maintenance personnel perform routine procedures on the product to keep it ...
IP4786CZ32 DVI and HDMI interface ESD and
... The DDC lines use a new buffering concept which decouples the internal capacitive load from the external capacitive load for use with standard Complementary Metal Oxide Semiconductor (CMOS) or Low Voltage Transistor-Transistor Logic (LVTTL) I/O cells down to 1.8 V. This buffering also redrives the D ...
... The DDC lines use a new buffering concept which decouples the internal capacitive load from the external capacitive load for use with standard Complementary Metal Oxide Semiconductor (CMOS) or Low Voltage Transistor-Transistor Logic (LVTTL) I/O cells down to 1.8 V. This buffering also redrives the D ...
Application Guidelines for Ground Fault Protection
... relays now offer negative-sequence current elements as a means of detecting ground faults and determining fault direction [4]. Conventional polarization techniques using zero-sequence voltage and current are implemented in nearly all microprocessor-based relays. Many of these relays also offer negat ...
... relays now offer negative-sequence current elements as a means of detecting ground faults and determining fault direction [4]. Conventional polarization techniques using zero-sequence voltage and current are implemented in nearly all microprocessor-based relays. Many of these relays also offer negat ...
RC-1160 / RC-1260 3.5 MB
... CAUTION indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. CAUTION may also be used to indicate other unsafe practices or risks of property damage. ...
... CAUTION indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. CAUTION may also be used to indicate other unsafe practices or risks of property damage. ...
IGLOO Icicle Evaluation Kit User`s Guide
... board is for accessory boards. It is a 38 pin connector. A set of the FPGA I/O pins are connected to this connector as well as some power pins. Spare I/Os from the FPGA have been wired to pads on the board for debug purposes. A top silkscreen of the Rev B board is shown in Figure 1-1 on page 6. A bo ...
... board is for accessory boards. It is a 38 pin connector. A set of the FPGA I/O pins are connected to this connector as well as some power pins. Spare I/Os from the FPGA have been wired to pads on the board for debug purposes. A top silkscreen of the Rev B board is shown in Figure 1-1 on page 6. A bo ...
Design of a Multi-Channel Integrated Circuit
... The thesis presents the design, simulation, and layout of an eight channel integrated circuit (IC) for use in nuclear physics experiments where particle identification, total pulse height, and relative timing information is needed. The design employs a technique known as pulse shape discrimination ( ...
... The thesis presents the design, simulation, and layout of an eight channel integrated circuit (IC) for use in nuclear physics experiments where particle identification, total pulse height, and relative timing information is needed. The design employs a technique known as pulse shape discrimination ( ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.