• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Specification for Impulse Voltage Generator
Specification for Impulse Voltage Generator

... situated in Johannesburg, South Africa at an altitude of 1800 metres above sea level. It is equipped to manufacture replacement windings for three phase transformers up to 800 MVA with voltages ranging up to 765 kV. The type of repairs carried out on the transformers necessitates HV electrical testi ...
Reactive & Voltage Maintenance - Joint Proposal
Reactive & Voltage Maintenance - Joint Proposal

TORQUE
TORQUE

...  1. The amount of force applied.  2. The distance the force is applied away from the center of the shaft. The torque, or turning force, is directly proportional to both force and distance. The more force you apply, the greater the torque. Also, the longer the crank handle, the greater the torque. ...
Strain Sensors 14th June, 2013 Kaustubh Shinde and Obi Igwe
Strain Sensors 14th June, 2013 Kaustubh Shinde and Obi Igwe

... • Elimination of cords and plugs for charging ...
type approval certificate
type approval certificate

... Derating curve up to 50°C is to be observed. ELR 3-230AC/500AC- 2/-9/-16: 230 V AC input, 500 AC operational voltage, 2 A / 9 A / 16 A output current, zero voltage switch. Derating curve up to 50°C is to be observed. ELR 2+1- 24DC/500AC-37: 24 V DC input, 500 AC operational voltage, 37 A output curr ...
SAMPLE ELECTRICAL PI QUESTIONS 1. Why heat produce in AC
SAMPLE ELECTRICAL PI QUESTIONS 1. Why heat produce in AC

... and hysteresis in the core. Copper loss is a constant after the coil has been wound and therefore a measurable loss. Hysteresis loss is constant for a particular voltage and current. Eddy-current loss, however, is different for each frequency passed through the transformer. 34. Define IDMT relay? An ...
LECTURER-26 GENERATION OF IMPULSE CURRENTS Lightning
LECTURER-26 GENERATION OF IMPULSE CURRENTS Lightning

... representing the nominal wave front and wave tail times the tolerances allowed on these times are ±10%only. Apart from the standard impulse current, waves, rectangular waves of long duration are also used for testing. The waveshape should be nominally rectangular in shape. The rectangular waves gene ...
Introduction to Digital Multimeters
Introduction to Digital Multimeters

Transient responses due to various burial depths on a single long
Transient responses due to various burial depths on a single long

... The purpose for this paper is to determine the effective burial depth for a single long horizontal ground conductor which is part of a lightning protection system. In this study, transient responses behaviours of the ground conductor towards various burial depths with lightning excitation are presen ...
16890_chapter-18-transformers
16890_chapter-18-transformers

... – Describe how the ratio of the voltage, current, and number of turns are related with a transformer – Describe applications of a transformer – Identify different types of transformers ...
iVolt-Brochure
iVolt-Brochure

... In the UK, generating companies are required to provide customers with a voltage between 216V and 253V. The average voltage across the UK is 242V, but levels can fluctuate significantly throughout the day on each site. Across Europe, the standard voltage has been historically 220V. As a result, most ...
Electrical Force - University High School
Electrical Force - University High School

... Voltages add when cells are connected ...
talk
talk

... based on this. The supply voltage is decided based on the number of stages stacked and the gain needed. Start off with the ‘Vdd’ specified for the technology. The MOSETs are biased and we must ensure that all the transistors are operating in the saturation region (Vds > Vgs – Vth). Gate biasing volt ...
Bip Transistor 50V 10A VCE(sat);360mV NPN Single TO-220F-3FS
Bip Transistor 50V 10A VCE(sat);360mV NPN Single TO-220F-3FS

... Any and all SANYO Semiconductor Co.,Ltd. products described or contained herein are, with regard to "standard application", intended for the use as general electronics equipment. The products mentioned herein shall not be intended for use for any "special application" (medical equipment whose purpos ...
BAUR_violaTD_FINAL_english_TEXT
BAUR_violaTD_FINAL_english_TEXT

... produce a characteristic curve, the height and course of which allows for conclusions on the status. Trend analyses based on regular measurements over a long period are also helpful. Therefore, it is recommended to always carry out the diagnostics together to create comparison options while evaluati ...
power_supply_and_cables
power_supply_and_cables

... • From table on previous slide, PS output power per boardstack is 213.7W • Assume efficiency 70% (I think I measured it once on STAR SSD MPOD supplies; datasheet doesn’t say, we could inquire of course, but this is roughly about right figure) • PS input AC power per boardstack is 305.3W • PS input ...
2SD1781K
2SD1781K

... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
DC575 - LTC2410CGN Evaluation Kit Quick Start Guide
DC575 - LTC2410CGN Evaluation Kit Quick Start Guide

single phase to three phase power conversion using pwm technique
single phase to three phase power conversion using pwm technique

... Over the years, three-phase motors, more than single phase motors have been the main consideration in industries due to certain parameters such as; efficiency, torque ripples and power factor. In rural areas, in order to operate machine tools and rolling mills as well as in low power industrial appl ...
electronic interface control
electronic interface control

A Dual-VDD Low Power FPGA Architecture
A Dual-VDD Low Power FPGA Architecture

Current is now orange - power supplies made by ifm electronic
Current is now orange - power supplies made by ifm electronic

Megaline HO Spec
Megaline HO Spec

... The standard MegaLine aluminium housing comes with a natural anodized finish. Additional custom anodized finishes are available for an additional cost. MegaLine may be specified with fixed mounting clips or with Pivot Bracket mounting clips. The Pivot Bracket allows the installer to set a custom fix ...
ece 470 power systems i - Rose
ece 470 power systems i - Rose

Understanding the Basics of Electrical Systems
Understanding the Basics of Electrical Systems

... tems, such as a corner-grounded delta-connected system, are permitted to be grounded [250.26(4)], but this is beyond the scope of this book. ...
< 1 ... 1796 1797 1798 1799 1800 1801 1802 1803 1804 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report