• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
led retrofit options for linear fluorescent luminaires
led retrofit options for linear fluorescent luminaires

... indicates that a testing laboratory found a representative group of product samples met UL’s safety requirements, usually based on published standards. The typical listed product is a complete system meant to be “plug and play” or “drop in,” meaning nothing else needs to be done to the product other ...
MODELING AND ANALYSIS OF POWER TRANSFORMERS UNDER FERRORESONANCE PHENOMENON.
MODELING AND ANALYSIS OF POWER TRANSFORMERS UNDER FERRORESONANCE PHENOMENON.

... I would like to express mi gratitude to my supervisors for leading me throughout this 'transient'. To Francisco for his patience and his gentleness when leading our research. He always found the words to say to keep me motivated and focus in the goal. To José Antonio for always being there whiling t ...
SYNCRO AS-2M4 Brochure
SYNCRO AS-2M4 Brochure

... control panels. The 19” rack mount is particularly ideal for use in a combined FIP / QE90 EWIS panel or when fitting in IP rated enclosure. It houses and supports the entire FIP on a fully hinged swingout frame constructed of welded steel for strength and powder coated to match the fitted panel. The ...
Electrical Engineering Department
Electrical Engineering Department

... of impregnating and surface treatment materials are also to be used in this area. Moreover resistance materials are also used for different purposes as potential divider, heating and controlling element. This subject provides the necessary information regarding all above materials so that the studen ...
OPERATING MANUAL Model BD-80C High Frequency Corona
OPERATING MANUAL Model BD-80C High Frequency Corona

... seconds to do the same treatment at a distance of 1½ in. (38 mm). A qualitative feel for the distance over which the corona is effective can be obtained by visual inspection of the purple corona. This is best done in a darkened room. 3.1.5.2 A metallic conductor within about 2 in. (50 mm) of the ele ...
Chapter 5: X-Ray Production
Chapter 5: X-Ray Production

A Guide To Diagnostic Insulation Testing Above 1 kV
A Guide To Diagnostic Insulation Testing Above 1 kV

... The appearance of electronics and the development of battery technology revolutionized the design of insulation testers. Modern instruments are line or battery-powered and produce very stable test voltages under a wide variety of conditions. They are also able to measure very small currents so that ...
PACSystems* RX3i CEP - GE Intelligent Platforms
PACSystems* RX3i CEP - GE Intelligent Platforms

... terminals. Use an M3 screw, star lock washer and a flat washer to connect the wire at the Carrier’s grounding hole. Connect the other end of the ground wire to a tapped hole in the grounded mounting panel or enclosure, using a machine screw, star lock washer and flat washer. Alternately, if the pane ...
ERP Protection Relays Test Technical Teaching Equipment
ERP Protection Relays Test Technical Teaching Equipment

... This is a teaching unit which gives students theorical and practical experience with several industrial application relays. The numerous devices, inputs and outputs, along with a modular structure, allow to use the ERP-UB for a wide range of protection applications simulation and real test of indust ...
ppt - glast lat
ppt - glast lat

TS3L501E 数据资料 dataSheet 下载
TS3L501E 数据资料 dataSheet 下载

... lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used betw ...
Contactors and relays
Contactors and relays

... contactors at between 85 to 110 % of the rated control circuit voltage. The DC operated DILM17 to DILM225A contactors now cover an even wider range in which they switch reliably. They allow reliable operation between 0.7 x Ucmin and 1.2 x Ucmax of the rated actuation voltage. The greater voltage tol ...
LASER PRINTER Phaser 3450
LASER PRINTER Phaser 3450

RECORDERS  8460-DAS1600 – DAS800-DAS801 INSTRUCTION MANUAL
RECORDERS 8460-DAS1600 – DAS800-DAS801 INSTRUCTION MANUAL

Operating experience with a generator stator end
Operating experience with a generator stator end

... Stator end-windings are excited by electromagnetic forces during the operation. The vibration amplitudes are proportional to the square of the current and the frequency is twice the electrical line frequency. On endwindings with loose supports, larger vibration amplitudes can be measured at partial ...
Controller Pro Instruction Manual
Controller Pro Instruction Manual

... A serial cable with a male DB-9 connector and USB adapter listed below. o Cables to Go, Port Authority™ 2 USB to Serial Adapter. www.cablestogo.com o Radio Shack, 6 Ft. (1.8m) USB-to-Serial Port Cable, Model: 26-183, Catalog #: 26-183 o Note: At this time, the Belkin USB-Serial Adapter Model #F5U103 ...
VOLTAGE FLUCTUATIONS CAUSED BY THE OPERATION OF A
VOLTAGE FLUCTUATIONS CAUSED BY THE OPERATION OF A

cnc routers
cnc routers

... Whatever the volume or scope of your manufacturing operations, talk to PLASQUIP today about an AXIS CNC Router solution that will not only meet, but also exceed your requirements. One of our team will be happy to guide you through the range of machines and options available so that we can provide a ...
CC1070 - Texas Instruments
CC1070 - Texas Instruments

Advant OCS with Master software S800 I/O Product Guide
Advant OCS with Master software S800 I/O Product Guide

... A range of I/O modules is available covering analog and digital signals of various types, and interfaces for RTDs and TCs of various types. The S800 I/O system provides I/O modules with typically 4, 8 or 16 channels depending on type and ratings of the individual module. All I/O modules are supervis ...
NX3V1T384 1. General description Low-ohmic single-pole single-throw analog switch
NX3V1T384 1. General description Low-ohmic single-pole single-throw analog switch

... 1. General description The NX3V1T384 is a low-ohmic single-pole single-throw analog switch. It has two input/output terminals (Y and Z) and an active LOW enable input pin (E). When E is HIGH, the analog switch is turned off. Schmitt trigger action at the enable input (E) makes the circuit tolerant t ...
Document
Document

AD7709 数据手册DataSheet下载
AD7709 数据手册DataSheet下载

... When the part is placed in power-down mode for a single conversion/second, at an update rate of 19.79 Hz, the current consumption is higher compared to when the part is placed in standby mode as the crystal oscillator takes approximately 100 ms to begin clocking. The device will, therefore, use full ...
AN103: Using the On-Chip Temperature Sensor
AN103: Using the On-Chip Temperature Sensor

Electrical characterization of acupuncture points
Electrical characterization of acupuncture points

... Various electrical measures, such as electrical resistance, impedance, and potential, have been used to detect and monitor acupuncture points. To appreciate how these measures differ, fundamental electrical concepts must be understood. Most electrodermal devices deliver an electrical stimulus to the ...
< 1 ... 96 97 98 99 100 101 102 103 104 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report