• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LM2596 SIMPLE SWITCHER Power Converter 150 kHz3A Step
LM2596 SIMPLE SWITCHER Power Converter 150 kHz3A Step

... FIGURE 1. Standard Test Circuits and Layout Guides As in any switching regulator, layout is very important. Rapidly switching currents associated with wiring inductance can generate voltage transients which can cause problems. For minimal inductance and ground loops, the wires indicated by heavy lin ...
Installation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual

Modelica Implementation of Field oriented Controlled 3 phase
Modelica Implementation of Field oriented Controlled 3 phase

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Fig. 3 Voltage conversion ratio of a series-parallel resonant converter independency on the load and on the normalized switching frequency The voltage conversion ratio curves also show that the output voltage can be regulated at no load. Thus, the main disadvantage of the series resonant converter i ...
Design Challenges in Backlighting LCD TVs
Design Challenges in Backlighting LCD TVs

... the ac waveforms will have a high crest factor when the dcinverter supply voltage is high. This makes the push-pull drive scheme inappropriate for notebook PCs but ideal for LCD TVs where the dc-inverter supply voltage is regulated to within ±20% or less. 2. Driving multiple lamps. CCFL lamps have b ...
Basic Principles of Adjustable Frequency Drives
Basic Principles of Adjustable Frequency Drives

HPE Power Advisor: A tool for estimating power requirements for
HPE Power Advisor: A tool for estimating power requirements for

... Configuring a system of single-node servers ........................................................................................................................................................................................................................................................ 12 Conf ...
QUESTION BANK SPECIAL ELECTRICAL MACHINES
QUESTION BANK SPECIAL ELECTRICAL MACHINES

... parameters: winding inductance = 30 mH, rated current = 3A, DC supply = 45V, total resistance in each phase = 15Ω. When the transistors are turned off, determine (i) the time taken by the phase current to decay to zero and (ii) the proportion of the stored inductive energy returned to the supply. 18 ...
MAX8662/MAX8663 Power-Management ICs for Single-Cell, Li+ Battery-Operated Devices General Description
MAX8662/MAX8663 Power-Management ICs for Single-Cell, Li+ Battery-Operated Devices General Description

... Maxim’s Smart Power Selector™ (SPS) safely distributes power between an external power source (AC adapter, auto adapter, or USB source), battery, and the system load. When system load peaks exceed the external source capability, the battery supplies supplemental current. When system load requirement ...
ELECTRICAL MACHINES LABORATORY "................................................................"
ELECTRICAL MACHINES LABORATORY "................................................................"

... need for analyzing an electrical machine, as measuring devices, supply systems, management systems, protection systems, synchronism and rectification systems, etc. This unit is prepared for working to a maximum power of 1 KW and all the components are located within a compact box. Metallic box. ...
EE2403-QB
EE2403-QB

Slides, chapter 20 - University of Colorado Boulder
Slides, chapter 20 - University of Colorado Boulder

AN10777 LPC32x0 power supply design examples Rev. 01 — 22 January 2009
AN10777 LPC32x0 power supply design examples Rev. 01 — 22 January 2009

... interface, a 10-bit A/D converter with a touch screen sense option, and an external bus interface that supports SDR and DDR SDRAM as well as static devices. ...
Guide and Requirements for Service at 69000 to 287000
Guide and Requirements for Service at 69000 to 287000

... SECTION 3.0 - CUSTOMER ELECTRICAL REQUIREMENTS SUBSECTION 3.1 - EQUIPMENT REQUIREMENTS It will be necessary for customers to coordinate their station insulation with the incoming transmission line insulation. At 230 kV and 287 kV it is BC Hydro's practice to install overhead ground wires on transmis ...
Electronic Systems Protection Electronic Systems Protection
Electronic Systems Protection Electronic Systems Protection

RF7163 QUAD-BAND GSM850/EGSM900/DCS1800/ PCS1900 TRANSMIT MODULE
RF7163 QUAD-BAND GSM850/EGSM900/DCS1800/ PCS1900 TRANSMIT MODULE

... compliant transmit module with four interchangeable receive ports. This transmit module builds upon RFMD’s leading power amplifier with PowerStar® integrated power control technology, pHEMT switch technology, and integrated transmit filtering for best-in-class harmonic performance. The results are h ...
MAX13174E +5V Multiprotocol, Pin-Selectable Cable Terminator General Description
MAX13174E +5V Multiprotocol, Pin-Selectable Cable Terminator General Description

... RS-530A, RS-449, V.36, and X.21) with a 100Ω differential load, V.35 with a T-network load, or V.28 (RS-232) and V.10 (RS-423) with an open-circuit load for use with transceivers that have on-chip termination. The termination protocol can be selected by the serial interface cable wiring or by pin co ...
zener diode - WordPress.com
zener diode - WordPress.com

... With an open zener diode, the full unregulated voltage will be present at the output without a load. In some cases with full or partial loading an open zener could remain undetected. ...
Power converter optimal control for wind energy conversion systems
Power converter optimal control for wind energy conversion systems

... control theory permits the development of multi-variable controllers in order to obtain an optimal response of the system, to provide some robustness and to ensure stability. Using this technique during the controller synthesis process the worst disturbance signals case is contemplated, in this way, ...
DATA SHEET Tytan II D0-25-1/S
DATA SHEET Tytan II D0-25-1/S

... Fuse switch-disconnectors combine fuse protection of system parts with switching capability under load as well as when in overload. Tytan II series devices are main fuse switch-disconnectors for D01 and D02 fuses. Simultaneous isolation of all phases is ensured by the screwcap-less plug-in technolog ...
Presentation PPT File - RFIC Group @ Fudan University
Presentation PPT File - RFIC Group @ Fudan University

DC-DC Converter
DC-DC Converter

... Example 1: Step-Down DC-DC Converter supplied by 230V DC voltage. The load resistance equal to10Ω. Voltage drop across the chopper when it is ON equal to 2V. For a duty cycle of ...
AUS Word Document
AUS Word Document

Power Electronics - Talking Electronics
Power Electronics - Talking Electronics

... Solution. We have seen that transistor equivalent circuit of an SCR is composed of pnp transistor and npn transistor with collector of each transistor coupled to the base of the other. Since a triac is equivalent to two SCRs connected in inverse parallel (Refer back to Fig. 21.4), the transistor equ ...
L12 datasheet - Trossen Robotics
L12 datasheet - Trossen Robotics

... A 1.0 ms pulse commands the controller to fully retract the actuator, and a 2.0 ms pulse signals full extension. If the motion of the actuator, or of other servos in your system, seems erratic, place a 1–4Ω resistor in series with the actuator’s red V+ leadwire. PWM Mode: This mode allows control of ...
< 1 ... 95 96 97 98 99 100 101 102 103 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report