• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The Importance of the X/R Ratio in Low
The Importance of the X/R Ratio in Low

... Purpose of a Short Circuit Study The purpose of a short circuit study is to determine whether or not electrical equipment is rated properly for the maximum available fault current that the equipment may see. The study is performed using computer software first by modeling the system (conductors, tra ...
NOT Gate
NOT Gate

...  Similar for NAND/NOR. Can implement with multiple two-input gates, or with single CMOS circuit. ...
J5659
J5659

... for power converters, which are variable structure system due to their on and off switching operation. Frequency to the line frequency is low. The deterioration of control performance is these cases stem from the fact that the current loop crossover frequency has to be limited to about one tenth of ...
Modular Multilevel DC/DC converter architectures for HVDC taps
Modular Multilevel DC/DC converter architectures for HVDC taps

29371 Demonstrate knowledge of automotive electrical
29371 Demonstrate knowledge of automotive electrical

... conventional current flow, electron current flow, conductors, insulators, semi-conductors, attraction and repulsion of charges, potential, potential difference (p.d.), electromotive force (e.m.f.), counter e.m.f. ...
Science Medium Term Planning – Spring 1 (year 5)
Science Medium Term Planning – Spring 1 (year 5)

... When the children have made a simple buzzer circuit ask them to consider how to make the buzzer quieter. How many options can they list in their books? Discuss some answers, i.e. add more wires; add a cell with less voltage; add another component that will use the power like another buzzer or bulb. ...
power flow model of static var compensator - e
power flow model of static var compensator - e

... environmental impact aspects today are much more important than they used to be and need to be addressed in a serious way in conjunction with transmission development procedures[7],[8]. The basic operating requirements of an AC power system are that the synchronous generators must remain in synchron ...
8-NEC Changes for PV in 2014-SolarABCs 2013-7
8-NEC Changes for PV in 2014-SolarABCs 2013-7

... interrupter,  PV  type,  or  other  system  components  listed  to   provide  equivalent  protec
Conductors and Insulators
Conductors and Insulators

... What might happen if the wires we choose for this application were to have insufficient cross-sectional area? file 00168 Answer 7 An analogy: what would happen if the water pipes in a municipal water supply system were sized too small? Notes 7 The effects of undersized wiring are multiple: not only ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... Abstract: An organised method for derivation of a multiport converter (MPC) with optimized fuzzy concept is proposed in this paper. The MPC is trigger by interconnecting multiple pulsating voltage cells (PVCs) through the DLIs. The PVCs can be load, yield, and bidirectional type, and bidirectional M ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

1.Introduction
1.Introduction

G:\Power Management\7937\HT7937v150-20160625.vp
G:\Power Management\7937\HT7937v150-20160625.vp

... It is also important to note that for an input voltage supply which can be maintained at 5.0V or higher, the device possesses even higher drive capabilities which can drive a higher number of parallel connected LEDs. The following table depicts the maximum LED numbers possible for this higher input ...
weighted total harmonic distortion
weighted total harmonic distortion

... Abstract- This paper presents harmonic and power quality analysis of two level and three level Diode Clamped Voltage Source Inverter (DCVSI). Purpose of analysis is to investigate performance of VSI in WECS in terms of power quality fed to grid, filter requirement and DC bus utilization. Modulation ...
Logical Design Design with Basic Logic Gates
Logical Design Design with Basic Logic Gates

9. RC Time Constant
9. RC Time Constant

... the square wave) of the falling trace, and set the reference voltage level at the bottom of the square wave. 13. Measure time and voltage along the discharge trace: Use cursor 2 to measure the time and voltages of five points on the trace. To ensure that the same point is measured as you switch from ...
ECEN 2612 Two-Port Circuits
ECEN 2612 Two-Port Circuits

...  To find the transfer impedance z21 assume that port 2 is open, so I2 is 0. Then apply a test voltage across port 1. Measure the current I1 and the voltage V2 while holding the test voltage V1 constant. A test voltage of 10V will work for these measurements.  To find the transfer impedance z12 ass ...
Littelfuse Introduces Single Fuse Solution for Applications that
Littelfuse Introduces Single Fuse Solution for Applications that

... Avoids need to parallel multiple fuses or over-spec industrial-type fuses to handle high currents NUREMBERG, GERMANY, May 17, 2017 — Littelfuse, Inc., the global leader in circuit protection, today introduced a series of UL approved high current, surface mount fuses in conjunction with the Power Con ...
TR41.9.1-06-11-004- Proposed Revisions to TIA-968
TR41.9.1-06-11-004- Proposed Revisions to TIA-968

... signal level control shall provide not exceed the programmed levels given in Table 4.5 within +/1 dB. The voltages impressed on resistor Rp by the data equipment shall be such as not to cause power dissipation in Rp in excess of 50 milliwatts. The circuit shown below was used in calculating values o ...
25 A, 60 V NPN Bipolar Power Transistor
25 A, 60 V NPN Bipolar Power Transistor

... The data of Figure 6 is based on TC = 25_C; TJ(pk) is variable depending on power level. Second breakdown pulse limits are valid for duty cycles to 10% but must be derated when TC w 25_C. Second breakdown limitations do not derate the same as thermal limitations. For inductive loads, high voltage an ...
Chapter 1
Chapter 1

... the system, such as component wear. As component wear and shift overlap times increase, the control unit adjusts line pressure by controlling a variable force motor or solenoid to maintain proper shift timing calibrations. 7. Engine speed, throttle position, temperature, engine load, and other typic ...
Chapter 8 Electrical Power 8.1 Introduction
Chapter 8 Electrical Power 8.1 Introduction

... The equipment considered is from the point of interconnection of Fermi 3 to the switchyard out to the 345 kV transmission system. Maximum and minimum switchyard voltage limits established by ITCTransmission will be applied to the 345 kV switchyard. Normal operating and abnormal procedures exist to m ...
SIMPLE SYSTEM PLANNING WITH REFUsol
SIMPLE SYSTEM PLANNING WITH REFUsol

... voltage that achieves the highest power for the solar generator in the current situation. This voltage will always lie between the MPP voltage of the shorter and the longer module strings and be close to the optimum for the individual string by around half the MPP module voltage in each case. As the ...
LD Didactic
LD Didactic

... The analog multimeter LD analog 10 has been designed and tested in accordance with the safety regulations IEC EN 61010-1. If the device is used appropriately, the safety of the multimeter and the security of the person using it are guaranteed. However, safety is not guaranteed if the multimeter is u ...
< 1 ... 793 794 795 796 797 798 799 800 801 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report