• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TDK-Lambda - SitesPlus
TDK-Lambda - SitesPlus

... TDK Corporation announces the introduction of the iBH series of 80W, 20A Point of Load (POL) nonisolated DC-DC converters, featuring a wide 0.7V to 5.5V output adjustment range. The iBH converters can operate from either 5V or 12Vdc bus voltages, having a wide input voltage range of 3.5V to 14V, red ...
ATV Transmitter from a Microwave Oven!
ATV Transmitter from a Microwave Oven!

... port. After an unknown number of degrees rotation within the feed structure (Matsushita would not provide tube data), this causes the magnetron to be pulled lower in frequency by some 25 MHz from its design frequency, ensuring legal amateur band operation. ...
Cooper Bussmann TVSA Series
Cooper Bussmann TVSA Series

... • Cell phones • Medical equipment C ...
Analysis of Different Topologies For Active Power Factor Correction
Analysis of Different Topologies For Active Power Factor Correction

Selecting the Optimum Transient Voltage Suppressor
Selecting the Optimum Transient Voltage Suppressor

... voltages in hand, examine the clamping-voltage ratings published in the manufacturer’s data sheets to identify suppressors falling within the required range. It is possible that there is no device that falls well within the upper and lower limits. If the device with the closest voltage rating falls ...
AMERITRON AL-811H
AMERITRON AL-811H

... The power supply in this amplifier uses a combination plate, filament and control transformer. A buck boost winding is provided to allow the user to compensate for low, medium or high power line voltage. This amplifier is normally supplied wired for the highest power line voltage setting. Never chan ...
ameritron al-811h instruction manual
ameritron al-811h instruction manual

pwrscale.pdf
pwrscale.pdf

... Express amp and have wired up switches to ground out different zeners in the string to produce a choice of B+ voltages in this amp. FWIW this switching has been dead quiet to my ears; the mechanical sound of the switch itself is all that I hear. I was just thinking that if a "variable zener" was cre ...
SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS® (PSS/E)  LAB1
SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS® (PSS/E) LAB1

... flow, equivalency, and switching studies. A common line interface is also available and students are encouraged to explore this method. It will not be covered in these labs. PSS®E provides the user with a wide range of assisting programs for installation, data input, output, manipulation and prepara ...
RBL,E Series - RECOM Power
RBL,E Series - RECOM Power

W12D1_Presentation_s13_v01_jwb
W12D1_Presentation_s13_v01_jwb

... resistor and switch. The switch is initially open but at t = 0 it is closed. A very long time after the switch is closed, the current in the circuit is ...
SVC Light® enabling strong flicker reduction from a steel plant in the
SVC Light® enabling strong flicker reduction from a steel plant in the

Circuit Note CN-0130
Circuit Note CN-0130

... performance (see Tutorial MT-031, Grounding Data Converters and Solving the Mystery of "AGND" and "DGND" and Tutorial MT-101, Decoupling Techniques). Note that Figure 1 is a simplified schematic and does not show all the necessary decoupling. Careful consideration of the power supply and ground retu ...
DC-USB 6-34V 10A, Intelligent DC-DC converter with USB interface
DC-USB 6-34V 10A, Intelligent DC-DC converter with USB interface

- Premier University of Technology
- Premier University of Technology

... receivers: configu ra lion. 0 peratton, noise sources, sensitivity calculation. performance curves. Design of analog and digital receivers. Transmission link analysis; point-to-point and point-tomufti-point links. system configuration, link power budget. rise time budget. line coding schemes. transm ...
Low Input Voltage, Current Mode PWM Buck Converter
Low Input Voltage, Current Mode PWM Buck Converter

... to an absolute maximum of 10V) and 100% duty cycle allows low dropout for maximum energy extraction from the battery. The part’s low quiescent current, 400µ A, with a shutdown current of 15µ A, extends battery life. Its user-selectable Burst Mode operation enhances efficiency at low load current. Fo ...
GQ3412071214
GQ3412071214

AN439 87C751 fast NiCad charger - Rcl
AN439 87C751 fast NiCad charger - Rcl

... It provides the correct polarity for the mosfet gate signal and its 1.5A peak output improves efficiency by switching the fet quickly. The Amobead is an optional component which reduces EMI at the expense of increased drain voltage swing. The scope traces were taken without the Amobead in place. ...
STP 3 & 4 8.2  Offsite Power Systems
STP 3 & 4 8.2 Offsite Power Systems

... double-circuit structures). The western right-of-way is 100 ft wide and contains a 345 kV circuit to Blessing. The middle or northwestern right-of-way is 400 ft wide and contains six (6) circuits. These circuits are carried on three sets of double-circuit towers. The Elm Creek 18 and the W.A.Parish ...
ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008
ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008

STK681-320
STK681-320

... damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical ...
Extending the input voltage range of the
Extending the input voltage range of the

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
INV350SU - Instruction Sheet
INV350SU - Instruction Sheet

... servicing. Only qualified service technicians should service this equipment. The use of parts supplied by other than Eaton’s Cooper Lighting business may result in an unsafe condition, equipment failure and will void the warranty. 3. BATTERY - The battery supplied in this equipment is a high ...
Computation of Transient Electromagnetic Fields Due to Switching
Computation of Transient Electromagnetic Fields Due to Switching

... computation resources also increase. This could even require a mesh generation algorithm to be employed. The simple substation model described here represents a step towards this goal. Typical bus lengths are 20–80 m long and located 5–15 m above ground. Thus, a bus section in a substation consistin ...
JH2416211626
JH2416211626

< 1 ... 724 725 726 727 728 729 730 731 732 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report