• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
WHY TO NOT USE AN OHMMETER TO SELECT
WHY TO NOT USE AN OHMMETER TO SELECT

... Electrical field behavior at various voltages in a hypothetical 1200V diode (not to scale) ...
INV550SI 550W Surface Mount Inverter Instruction Sheet
INV550SI 550W Surface Mount Inverter Instruction Sheet

... immediately. 9. Install in accordance with the National Electrical Code and local regulations. 10. Installation and servicing should be performed by qualified personnel. 11. Electricians and end-users need to ensure product system compatibility before final installation. 12. SAVE THESE INSTRUCTIONS ...
A SPICE MODEL FOR IGBTs
A SPICE MODEL FOR IGBTs

IOSR Journal of Computer Engineering (IOSR-JCE)
IOSR Journal of Computer Engineering (IOSR-JCE)

RSB16F2
RSB16F2

... The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants cont ...
Annex II: Template for the declaration of losses and
Annex II: Template for the declaration of losses and

... Option 2: Minimum Efficiency. The Commission recognises that power transformers are often specifically designed for a given installation. The procurement of power transformers often involves the specification of the anticipated loading point either directly or through the use of separate load and no ...
Electronic Ballasts - Lightline Electronics
Electronic Ballasts - Lightline Electronics

... windings. They can take all kinds of abuse both physical and electrical without failing. Electronic ballasts are made of circuit boards, relays, capacitors and transistors; they are far more delicate. They must be handled gently and be thoroughly protected from moisture, condensation and precipitati ...
SURGE ARRESTORS OR LIGHTNING ARRESTORS. Lightning
SURGE ARRESTORS OR LIGHTNING ARRESTORS. Lightning

eet 3086 switchgear and protection
eet 3086 switchgear and protection

... secondaries are also equal (Isin = Isout) because the current transformers are identical. When the current transformers are connected with the polarities indicated in Figure 1, the secondary currents flow round the circuit and no current flows in the coil of the protective relay (IR = 0), which can ...
APM Motor Control
APM Motor Control

CF25485491
CF25485491

... frequencies, the meter may register high or low depending on the harmonics present and the response of the meter to these harmonics. The problems caused by harmonic currents are overloading of neutrals, overheating of transformers, nuisance tripping of circuit breakers, over stressing of power facto ...
Switch_Mode_Converters
Switch_Mode_Converters

... (if TA- is ON and TA+ is OFF) :: output current will flow through TA- if io is negative or it will flow through DA- if io is positive The average output voltage of the converter leg A: ...
AND9056 - High Performance IGBT for Induction Heating
AND9056 - High Performance IGBT for Induction Heating

... production of these IH cookers. The market for induction heating applications will grow tremendously, if production costs can be reduced, and more efficient IH cookers can be developed. Several parameters are to be considered when optimizing an IGBT. These include physical device properties such as ...
Power Module Panel data sheet No. 1146
Power Module Panel data sheet No. 1146

... N.O.F.A. Normally Open Fire Alarm contacts supplied from the fire alarm system to initiate the shunt trip. Shunt Trip Solenoid for remote trip of switch, which is activated by the closing of the fire alarm contacts or key test switch. Option R2 Fire Safety Interface Relay that is operated at 24Vdc f ...
Digital Multimeter Advantages
Digital Multimeter Advantages

BP5034D12
BP5034D12

A 98nW Wake-up Radio for Wireless Body Area Networks
A 98nW Wake-up Radio for Wireless Body Area Networks

... parameters, such as the variation in data rate, architecture, and non-linearity present in the radios. The survey only covers ultra-low power receivers, common in BAN research; therefore, Bluetooth or Zigbee receivers with higher power will sit well above this line. A noticeable power floor around 5 ...
AUTOMATIC TRANSFER SYSTEm
AUTOMATIC TRANSFER SYSTEm

... Product Introduction ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

Aalborg Universitet
Aalborg Universitet

Liebert Precision Power Center Packaged Power Distribution For Higher Power Quality
Liebert Precision Power Center Packaged Power Distribution For Higher Power Quality

4062
4062

... leakage inductance, and increases the coupling of the windings which results in overall increased circuit efficiency. Forward Circuits DRQ Series: DRQ73, DRQ74, DRQ125, DRQ127 The Forward transformer only provides isolation and voltage scaling. The SDQ Series: SDQ12, SDQ25 Forward allows multiple ou ...
Installation Guide Contents
Installation Guide Contents

Medical Power Conditioning Presentation
Medical Power Conditioning Presentation

... G Balanced power transformers have their ground separated from phase and neutral by 60 volts. Neutral and ground cannot be bonded and common mode voltage is not eliminated. Balanced power transformers are primarily designed to eliminate 60 Hz. hum. They are not intended for microprocessor based elec ...
HSC Physics - Dux College
HSC Physics - Dux College

... dramatically. This leads to the construction of more AC generators and power plants, which have a significantly detrimental effect on the environment. For example, generators powered by water turbines require the construction of large dams. Large areas of land must be cleared for dam construction, w ...
< 1 ... 728 729 730 731 732 733 734 735 736 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report