LTC4412 - Low Loss PowerPath TM Controller in ThinSOT
... Important parameters for the selection of MOSFETs are the maximum drain-source voltage VDS(MAX), threshold voltage VGS(VT) and on-resistance RDS(ON). The maximum allowable drain-source voltage, VDS(MAX), must be high enough to withstand the maximum drainsource voltage seen in the application. The ma ...
... Important parameters for the selection of MOSFETs are the maximum drain-source voltage VDS(MAX), threshold voltage VGS(VT) and on-resistance RDS(ON). The maximum allowable drain-source voltage, VDS(MAX), must be high enough to withstand the maximum drainsource voltage seen in the application. The ma ...
BDTIC www.BDTIC.com/infineon AN2011-01 – Module Adapter
... input of the amplifier located on the MA40xExx. Therefore the major amount of current for recharging the gate is derived from the gate driver power supply instead of being drained through the clamping diodes. This provides more consistent clamping voltage due to operating the clamping diodes at a lo ...
... input of the amplifier located on the MA40xExx. Therefore the major amount of current for recharging the gate is derived from the gate driver power supply instead of being drained through the clamping diodes. This provides more consistent clamping voltage due to operating the clamping diodes at a lo ...
AN3 - Applications for a Switched-Capacitor Instrumentation Building Block
... particularly those associated with stray capacitance and switch timing. Until now, these techniques have been used only in the internal construction of monolithic devices. A new device, the LTC®1043, makes these switches available for board-level use. Multi-pole switching and a self-driven, non-over ...
... particularly those associated with stray capacitance and switch timing. Until now, these techniques have been used only in the internal construction of monolithic devices. A new device, the LTC®1043, makes these switches available for board-level use. Multi-pole switching and a self-driven, non-over ...
master specification - OPS Schneider Electric
... Four 0-1 mA inputs and four 0-1 mA outputs, or Four 0-20 mA inputs and four 0-20 mA outputs. All analog inputs and/or outputs are accurate to within 0.3% of full scale. The analog I/O option is not available with the “remote display” model. The analog I/O option is not available with any o ...
... Four 0-1 mA inputs and four 0-1 mA outputs, or Four 0-20 mA inputs and four 0-20 mA outputs. All analog inputs and/or outputs are accurate to within 0.3% of full scale. The analog I/O option is not available with the “remote display” model. The analog I/O option is not available with any o ...
1-MHz 45-µA CMOS RAIL-TO-RAIL OPERATIONAL AMPLIFIER OPA2348-Q1 OPA4348-Q1 FEATURES
... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absol ...
... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absol ...
Ameren TO Planning Criteria Guidelines
... orderly and economic development of the Ameren bulk power supply system facilities 100 kV and above, and for performing operational planning to assess reliability under near-term conditions on behalf of its transmission owning affiliates, including Ameren Missouri, Ameren Illinois, and Ameren Transm ...
... orderly and economic development of the Ameren bulk power supply system facilities 100 kV and above, and for performing operational planning to assess reliability under near-term conditions on behalf of its transmission owning affiliates, including Ameren Missouri, Ameren Illinois, and Ameren Transm ...
mv controller - Siemens Industry, Inc.
... The relays shall provide complete sequence-of-events recording, time stamped every millisecond. The relays shall provide oscillography (waveform) capture, with configurable pre- and post-fault data capture times.] ...
... The relays shall provide complete sequence-of-events recording, time stamped every millisecond. The relays shall provide oscillography (waveform) capture, with configurable pre- and post-fault data capture times.] ...
HMC427LP3 数据资料DataSheet下载
... General Description The HMC427LP3 & HMC427LP3E are low loss broadband positive control transfer switches in leadless surface mount packages. Covering DC to 8 GHz, this switch offers high isolation and low insertion loss. The switch operates using a positive control voltage of 0/+5V and requires a fi ...
... General Description The HMC427LP3 & HMC427LP3E are low loss broadband positive control transfer switches in leadless surface mount packages. Covering DC to 8 GHz, this switch offers high isolation and low insertion loss. The switch operates using a positive control voltage of 0/+5V and requires a fi ...
Power and Grounding for Audio and Audio/Video
... current can be much larger than that for rated sine wave power, but the current peaks quickly, and rarely lasts more than a few hundred milliseconds. Circuit breakers are designed and specified to protect the electrical system in the case of a fault, especially from overheating due to excessive curr ...
... current can be much larger than that for rated sine wave power, but the current peaks quickly, and rarely lasts more than a few hundred milliseconds. Circuit breakers are designed and specified to protect the electrical system in the case of a fault, especially from overheating due to excessive curr ...
ORIGINATION FORM
... 685-2.2.4 Electrical: UPS assemblies used to provide backup power in an ITS cabinet must provide a minimum of 350 watts (at 120VAC) of continuous backup power for a minimum of two hours unless otherwise shown in the Plans. UPS assemblies used to provide backup power in a traffic signal controller ca ...
... 685-2.2.4 Electrical: UPS assemblies used to provide backup power in an ITS cabinet must provide a minimum of 350 watts (at 120VAC) of continuous backup power for a minimum of two hours unless otherwise shown in the Plans. UPS assemblies used to provide backup power in a traffic signal controller ca ...
Pad-Mounted Single-Phase 32-Step Voltage
... Pad-Mounted Single-Phase 32-Step Voltage Regulator with Communication-Ready Controls Technical Specifications Pad-Mounted Voltage Regulator Introduction This specification covers electrical, mechanical, and safety features and characteristics of outdoor, padmounted, single-phase, fluid-immersed, ste ...
... Pad-Mounted Single-Phase 32-Step Voltage Regulator with Communication-Ready Controls Technical Specifications Pad-Mounted Voltage Regulator Introduction This specification covers electrical, mechanical, and safety features and characteristics of outdoor, padmounted, single-phase, fluid-immersed, ste ...
±5V, 250mA Dual Output Power Supply (Rev. A)
... Figure 6. VPOS Boost Converter Internal Block Diagram 8.3.1.1 Switching Frequency (VPOS) The boost converter switching frequency may vary slightly as the operating conditions change, but is typically around 1.7 MHz for most operating conditions. 8.3.1.2 Output Voltage (VPOS) The boost converter's ou ...
... Figure 6. VPOS Boost Converter Internal Block Diagram 8.3.1.1 Switching Frequency (VPOS) The boost converter switching frequency may vary slightly as the operating conditions change, but is typically around 1.7 MHz for most operating conditions. 8.3.1.2 Output Voltage (VPOS) The boost converter's ou ...
PROTECTIVE RELAYING FOR TRANSMISSION AND
... becomes humanly impossible to do so before taking place of damage to equipment / property and life. As such, special equipment referred as protective Gear equipment is required to be employed to sense the trouble and disconnect the faulty equipment section from the rest of the system in time to mini ...
... becomes humanly impossible to do so before taking place of damage to equipment / property and life. As such, special equipment referred as protective Gear equipment is required to be employed to sense the trouble and disconnect the faulty equipment section from the rest of the system in time to mini ...
Harmonic Analysis in Electrical Power System with Electric Arc
... problem to the power system quality whereas single phase has all similar property except the unbalancing problem. The power quality is mainly affected by flicker, voltage and current harmonics. Flicker causes voltage fluctuations in the connected electrical network which in turn can affect other use ...
... problem to the power system quality whereas single phase has all similar property except the unbalancing problem. The power quality is mainly affected by flicker, voltage and current harmonics. Flicker causes voltage fluctuations in the connected electrical network which in turn can affect other use ...
Quick Installation Guide PVI-3.8/4.6-I
... resistance measured by the inverter are shown on the display. The inverter ONLY creates a parallel with the grid if the grid parameters fall within the range foreseen by current regulations and if the insulation resistance falls within the set parameters. --If the preliminary checks for parallel con ...
... resistance measured by the inverter are shown on the display. The inverter ONLY creates a parallel with the grid if the grid parameters fall within the range foreseen by current regulations and if the insulation resistance falls within the set parameters. --If the preliminary checks for parallel con ...
Model Number Structure Ordering Information
... the setting dial, LEDs, and resin parts, possibly resulting in malfunction or display defects. Perform periodic inspections and part replacements. We recommend that you use a surge absorber if surge voltages may occur. When you dispose of the Timer, do so according to all local ordinances for proces ...
... the setting dial, LEDs, and resin parts, possibly resulting in malfunction or display defects. Perform periodic inspections and part replacements. We recommend that you use a surge absorber if surge voltages may occur. When you dispose of the Timer, do so according to all local ordinances for proces ...
quicktronic® controllable 14w t5 systems
... compatibility or reliability. Gone are the days of complex wiring and commissioning schemes that often require specialized integrators to configure and troubleshoot devices from multiple suppliers. The MULTISTEP ballasts also incorporate high-performance features of Universal voltage, PROStart and Q ...
... compatibility or reliability. Gone are the days of complex wiring and commissioning schemes that often require specialized integrators to configure and troubleshoot devices from multiple suppliers. The MULTISTEP ballasts also incorporate high-performance features of Universal voltage, PROStart and Q ...
Aalborg Universitet three-phase Voltage Source Inverters
... overcome such effects, the closed-loop output impedance of the inverter is adjusted by, either changing the bandwidth of the voltage control loop [7], or inserting a virtual impedance loop [8]. Since the injection of noncharacteristic frequency signal is needed in [7], it requires advanced signal pr ...
... overcome such effects, the closed-loop output impedance of the inverter is adjusted by, either changing the bandwidth of the voltage control loop [7], or inserting a virtual impedance loop [8]. Since the injection of noncharacteristic frequency signal is needed in [7], it requires advanced signal pr ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.