• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Data Sheet - Energy Recovery Products
Data Sheet - Energy Recovery Products

... data sheets and/or specificaNons can and do vary in different applicaNons and actual performance may vary over Nme. All operaNng parameters, including “Typicals” must be validated for each customer applicaNon by customer’s technical experts. ERP does not convey any license under its patent rights nor ...
What transients are and why you need protection
What transients are and why you need protection

Sep 1992 Design Techniques for Electrostatic Discharge Protection
Sep 1992 Design Techniques for Electrostatic Discharge Protection

... experienced by the DB25 (RS232) connector. Making LTC’s RS232 parts more rugged to the tune of 10kV is another engineering triumph from the designers at LTC. This issue includes two articles on our high-speed operational amplifiers. The first is a collection of circuits designed around the low cost ...
LTC2920-1/LTC2920-2 - Single/Dual Power Supply Margining
LTC2920-1/LTC2920-2 - Single/Dual Power Supply Margining

... these resistors are usually calculated by the design engineer using two different equations supplied by the manufacturer. There is usually one equation for trimming the voltage up, and another equation for trimming the voltage down. In most cases, the power supply module is treated like a “black box ...
Understanding NEC 409 & UL 508A Short Circuit Ratings
Understanding NEC 409 & UL 508A Short Circuit Ratings

BSX - Thermon
BSX - Thermon

... BSX self-regulating heating cables are designed to provide freeze protection or process temperature maintenance to metallic and nonmetallic piping, tanks and equipment. The heat output of BSX cable varies in response to the surrounding conditions along the entire length of a circuit. Whenever the he ...
EDS 08-0136 LV Network Design - Document Library
EDS 08-0136 LV Network Design - Document Library

twelve pulse scr control board
twelve pulse scr control board

... angle to control the portion of the input voltage that is conducted to the output. The BAP3012 has two phase locking circuits that independently phase lock to both transformer secondaries, which creates the phase references required to control the conduction angle of the six SCRs in each bridge. Pha ...
Hybrid Multilevel Power Conversion System: A Competitive Solution for High-Power Applications
Hybrid Multilevel Power Conversion System: A Competitive Solution for High-Power Applications



Adjustment Data MAZDA - 626 - 1.8i 16V
Adjustment Data MAZDA - 626 - 1.8i 16V

... connects this terminal to ground. The voltage on this terminal is during this time 0 Volts. During the time the solenoid is switched off, the voltage on this terminal is 12 Volts. Some motormanagement systems control the amount gases delivered to the intake manifold switching the solenoid on and of ...
Recitations with Matt Leone
Recitations with Matt Leone

... by observing a sinusoidally driven RC circuit using  DC many different driving frequencies. Use the same circuit set up as in the previous part of the lab. As you increase the driving frequency, the amplitude of the resistor voltage will increase because the total circuit R impedance is decreasing, ...
60 kV to 500 kV Technical Interconnection Requirements
60 kV to 500 kV Technical Interconnection Requirements

... BC Hydro’s review of the specifications and detailed plans shall not be construed as confirming or endorsing the design or as warranting the safety, durability or reliability of the PGF. BC Hydro, by reason of such review or lack of review, shall be responsible for neither the strength, adequacy of ...
Model Paper for LACCEI Proceedings
Model Paper for LACCEI Proceedings

... each goes about their implementation. As stated in the above abstract, both analog and digital circuits will be used for simulation; although it will not be used in this article both simulation platforms also support mixed signal IC simulations. Lastly, an observation into the role that the higher a ...
Lovato Electric | Energy and Automation
Lovato Electric | Energy and Automation

Technical performance requirements for the connection of large
Technical performance requirements for the connection of large

... lightly loaded area and compliance with voltage standards will be achieved; or where the active power output may improve reactive power margins on the network without additional reactive power capability. Any such negotiation is dependent on the network at the connection point. If the generating sys ...
Aalborg Universitet Iov, Florin; Valentini, Massimo; Akhmatov, V.; Thisted, Jens
Aalborg Universitet Iov, Florin; Valentini, Massimo; Akhmatov, V.; Thisted, Jens

Lab #1: Batteries, DC bench supplies, and resistors
Lab #1: Batteries, DC bench supplies, and resistors

...  Using DMM to measure voltage and resistance  Nominal values vs. actual measured values  Parallel and series resistor combinations  Using DMM to analyze voltage divider circuits Lab #2: Ohm’s and Kirchhoff’s Circuit Laws Platform: breadboard, potentiometer from parts kit  KVL and KCL  Measurin ...
MAX15091/MAX15091A Evaluate: MAX15091/MAX15091A Evaluation Kits General Description
MAX15091/MAX15091A Evaluate: MAX15091/MAX15091A Evaluation Kits General Description

... The MAX15091 evaluation kit (EV kit) provides a proven design to evaluate the MAX15091 hot-swap controller with an integrated 9A MOSFET. The EV kit is configured to pass 9A in a 2.7V to 18V hot-swap application, thus providing a fully integrated solution. The EV kit uses the MAX15091ETI+ in a 5mm x ...
LT6205/LT6206/LT6207 - Single/Dual/Quad Single Supply 3V, 100MHz Video Op Amps
LT6205/LT6206/LT6207 - Single/Dual/Quad Single Supply 3V, 100MHz Video Op Amps

... The inputs can be driven beyond the supplies without damage or phase reversal of the output. Isolation between channels is high, over 90dB at 10MHz. The LT6205 is available in the 5-pin SOT-23, and the LT6206 is available in an 8-lead MSOP package with standard op amp pinouts. For compact layouts th ...
ADC`S ANALOG TO DIGITAL CONVERTERS
ADC`S ANALOG TO DIGITAL CONVERTERS

... 16) in which after each guess the one making the guesses is told if her last guess is high or low. If a young child were playing the game, he might just make random guesses. A slightly older child would start at the lowest number and just start counting name all of the numbers until they hit the cho ...
1.5MHz, 1A, STEP DOWN DC-DC CONVERTER     ... Data Sheet  Features
1.5MHz, 1A, STEP DOWN DC-DC CONVERTER ... Data Sheet Features

... heat due to its high efficiency. However, in some conditions when the part is operating in high ambient temperature with high RDS(ON) resistance and high duty cycles, such as in LDO mode, the heat dissipated may exceed the maximum junction temperature. To avoid the part from exceeding maximum juncti ...
MAX8795A TFT-LCD DC-DC Converter with Operational Amplifiers General Description
MAX8795A TFT-LCD DC-DC Converter with Operational Amplifiers General Description

... included is a logic-controlled, high-voltage switch with adjustable delay. The step-up DC-DC converter provides the regulated supply voltage for the panel source driver ICs. The converter is a high-frequency (1.2MHz) current-mode regulator with an integrated 20V n-channel MOSFET that allows the use ...
Power Extender 0-10VDC Dimming Control INSTALLATION
Power Extender 0-10VDC Dimming Control INSTALLATION

... Return (To Ballast) ...
BD733L5FP-C
BD733L5FP-C

... Exceeding the absolute maximum rating for supply voltage, operating temperature or other parameters can result in damages to or destruction of the chip. In this event it also becomes impossible to determine the cause of the damage (e.g. short circuit, open circuit, etc.). Therefore, if any special m ...
< 1 ... 280 281 282 283 284 285 286 287 288 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report