MAX44264 Ultra-Low Power Op Amp in a Tiny 6
... The common-mode input range of the MAX44264 extends down to ground, and offers excellent commonmode rejection. These devices are guarante ed not to undergo phase reversal when the input is overdriven. Power Supplies and Layout applications, good layout is extremely important because low-power requir ...
... The common-mode input range of the MAX44264 extends down to ground, and offers excellent commonmode rejection. These devices are guarante ed not to undergo phase reversal when the input is overdriven. Power Supplies and Layout applications, good layout is extremely important because low-power requir ...
MAX16826 Programmable, Four-String HB LED Driver with Output-Voltage Optimization and Fault Detection
... designed for backlighting automotive LCD displays and other display applications such as industrial or desktop monitors and LCD televisions. The MAX16826 integrates a switching regulator controller, a 4-channel linear current sink driver, an analog-to-digital converter (ADC), and an I2C interface. T ...
... designed for backlighting automotive LCD displays and other display applications such as industrial or desktop monitors and LCD televisions. The MAX16826 integrates a switching regulator controller, a 4-channel linear current sink driver, an analog-to-digital converter (ADC), and an I2C interface. T ...
Circuit Breakers - Instantaneous Trip Region
... understood, re-read the previous section “Circuit Breaker Coordination Medium to High Level Fault Currents.” How does this affect the electrical system? Look at the one-line diagram below. For any fault current greater than approximately 6500A on the load side of the 100A circuit breaker, the 1200A ...
... understood, re-read the previous section “Circuit Breaker Coordination Medium to High Level Fault Currents.” How does this affect the electrical system? Look at the one-line diagram below. For any fault current greater than approximately 6500A on the load side of the 100A circuit breaker, the 1200A ...
TEM Transmission Lines
... Figure 7.1.1 Parallel-plate TEM transmission line. Although this computed voltage v(t,z) does not depend on the path of integration connecting the two plates, provided it is at constant z, it does depend on z itself. Thus there can be two different voltages between the same pair of plates at differe ...
... Figure 7.1.1 Parallel-plate TEM transmission line. Although this computed voltage v(t,z) does not depend on the path of integration connecting the two plates, provided it is at constant z, it does depend on z itself. Thus there can be two different voltages between the same pair of plates at differe ...
MAX8556/MAX8557 4A Ultra-Low-Input-Voltage LDO Regulators General Description
... 200mV of dropout (max). The pMOS output stage can be driven from input voltages down to 1.425V without sacrificing stability or transient performance. Supply current is not a significant function of load or input headroom because this regulator has a pMOS output device. The MAX8556/MAX8557 are fully ...
... 200mV of dropout (max). The pMOS output stage can be driven from input voltages down to 1.425V without sacrificing stability or transient performance. Supply current is not a significant function of load or input headroom because this regulator has a pMOS output device. The MAX8556/MAX8557 are fully ...
A1126: Chopper-Stabilized Omnipolar Hall-Effect Switch
... to the offset that can be produced at the output of the Hall sensor chip. This makes it difficult to process the signal while maintaining an accurate, reliable output over the specified operating temperature and voltage ranges. Chopper stabilization is a unique approach used to minimize Hall offset ...
... to the offset that can be produced at the output of the Hall sensor chip. This makes it difficult to process the signal while maintaining an accurate, reliable output over the specified operating temperature and voltage ranges. Chopper stabilization is a unique approach used to minimize Hall offset ...
SECTION 260553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS
... underground-line warning tape directly above line at 6 to 8 inches below finished grade. Use multiple tapes where width of multiple lines installed in a common trench or ...
... underground-line warning tape directly above line at 6 to 8 inches below finished grade. Use multiple tapes where width of multiple lines installed in a common trench or ...
The Bidirectional Control Thyristor (BCT)
... transformer tap changers in power quality applications. In such high voltage applications several thyristor levels are often required in the valve, each level comprising two thyristors. Conventionally, each thyristor needs its own mounting clamps and connections to the cooling circuit. In some appli ...
... transformer tap changers in power quality applications. In such high voltage applications several thyristor levels are often required in the valve, each level comprising two thyristors. Conventionally, each thyristor needs its own mounting clamps and connections to the cooling circuit. In some appli ...
Electrical Injuries: Etiology, Pathophysiology and Mechanism of Injury
... exposure to outside power lines and the most commonly occur when a conductive object touches an overhead high voltage power line. Rarely, patients get into electrical switching equipment and directly touch energized component. - Lightning injuries- involve voltages higher than those of the other inj ...
... exposure to outside power lines and the most commonly occur when a conductive object touches an overhead high voltage power line. Rarely, patients get into electrical switching equipment and directly touch energized component. - Lightning injuries- involve voltages higher than those of the other inj ...
MAX9164 3.3V Single LVDS Driver/Receiver General Description Features
... The MAX9164 high-speed LVDS driver/receiver is designed specifically for low-power point-to-point applications. The MAX9164 operates from a single 3.3V power supply, and is pin compatible with the DS90LV019. The device features an independent differential driver and receiver. The MAX9164 driver outp ...
... The MAX9164 high-speed LVDS driver/receiver is designed specifically for low-power point-to-point applications. The MAX9164 operates from a single 3.3V power supply, and is pin compatible with the DS90LV019. The device features an independent differential driver and receiver. The MAX9164 driver outp ...
a CMOS 3 V/5 V, Wide Bandwidth Quad 2:1 ADG784
... range ensuring excellent linearity and low distortion when switching audio signals. Fast switching speed, coupled with high signal bandwidth, also makes the parts suitable for video signal switching. CMOS construction ensures ultralow power dissipation making the parts ideally suited for portable an ...
... range ensuring excellent linearity and low distortion when switching audio signals. Fast switching speed, coupled with high signal bandwidth, also makes the parts suitable for video signal switching. CMOS construction ensures ultralow power dissipation making the parts ideally suited for portable an ...
BU406/406H/408 NPN Epitaxial Silicon Transistor BU406/406H/408 — NPN Epit axi
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
Datasheet - Intersil
... The ISL24011 will level shift a digital input signal to an output voltage nearly equal to its output supply voltages. The ISL24011 has 3 supplies. VON1 and VON2 are positive supplies with a voltage range between +10V and +40V (absolute max). VOFF is the negative supply with a voltage range between - ...
... The ISL24011 will level shift a digital input signal to an output voltage nearly equal to its output supply voltages. The ISL24011 has 3 supplies. VON1 and VON2 are positive supplies with a voltage range between +10V and +40V (absolute max). VOFF is the negative supply with a voltage range between - ...
Casco diode - the key to high PFC efficiency BYC58X-600
... } Better cost/performance ratio compared to SiC Schottky ...
... } Better cost/performance ratio compared to SiC Schottky ...
APEJ-2014-08-0446
... C2’). This FCMLI consists of four switch pairs (S1,S1’), (S2,S2’), (S3,S3’) and (S4,S4’). The switches are clamped by DC-link together with flying capacitors. The four switches (S1-S4) must be connected in series between DC input and load and likewise for switches (S4’-S1’). The three flying capacit ...
... C2’). This FCMLI consists of four switch pairs (S1,S1’), (S2,S2’), (S3,S3’) and (S4,S4’). The switches are clamped by DC-link together with flying capacitors. The four switches (S1-S4) must be connected in series between DC input and load and likewise for switches (S4’-S1’). The three flying capacit ...
WEEK 5 sizing 1(2)
... a maximum voltage drop of 5% between the solar array and the inverter. If the inverter is located far from the point of connection to the grid then the AC voltage drop is also need to be included in this 5% 5.4.5 Inverter efficiency - There are losses in the inverter due to transformer losses, power ...
... a maximum voltage drop of 5% between the solar array and the inverter. If the inverter is located far from the point of connection to the grid then the AC voltage drop is also need to be included in this 5% 5.4.5 Inverter efficiency - There are losses in the inverter due to transformer losses, power ...
High Voltage SIL/SIP Reed Relays
... The Series 104 is a range of Single-In-Line reed relays intended for voltages that are beyond the capabilities of conventional SIL reed relays. They are ideal for such applications as transformer or cable testing or any other automatic test equipment where high voltages are involved. Where mains vol ...
... The Series 104 is a range of Single-In-Line reed relays intended for voltages that are beyond the capabilities of conventional SIL reed relays. They are ideal for such applications as transformer or cable testing or any other automatic test equipment where high voltages are involved. Where mains vol ...
PS9332L, PS9332L2 Data Sheet
... (If the pattern needs to be close to the input block, to prevent the LED from lighting during the off state due to the abovementioned coupling, design the input-side circuit so that the bias of the LED is reversed, within the range of the recommended operating conditions, and be sure to thoroughly e ...
... (If the pattern needs to be close to the input block, to prevent the LED from lighting during the off state due to the abovementioned coupling, design the input-side circuit so that the bias of the LED is reversed, within the range of the recommended operating conditions, and be sure to thoroughly e ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.