TPS2412, TPS2413 N+1 and ORing Power Rail Controller (Rev. C)
... MOSFET gate threshold voltage. If the external circuits force V(AC) below 10 mV and above the programmed fast turnoff, GATE is slowly turned off. GATE is rapidly pulled to ground if V(AC) falls to the RSET programmed fast turnoff threshold. The TPS2413 turns the MOSFET on and off like a comparator w ...
... MOSFET gate threshold voltage. If the external circuits force V(AC) below 10 mV and above the programmed fast turnoff, GATE is slowly turned off. GATE is rapidly pulled to ground if V(AC) falls to the RSET programmed fast turnoff threshold. The TPS2413 turns the MOSFET on and off like a comparator w ...
TL082
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
capacitor - Eportfolio@UTM
... The schematic symbol has an arrow to show that the component's value can be adjusted: ...
... The schematic symbol has an arrow to show that the component's value can be adjusted: ...
Metal-Enclosed Switchgear
... VCP-TL circuit breakers can be supplied with integral breaker mounted protective relays for overload and short-circuit protection and metering. The integral relays are self-powered from specially designed and tested current sensors. MEF switchgear can be supplied with external relays and meters conn ...
... VCP-TL circuit breakers can be supplied with integral breaker mounted protective relays for overload and short-circuit protection and metering. The integral relays are self-powered from specially designed and tested current sensors. MEF switchgear can be supplied with external relays and meters conn ...
Low Dropout 1 Ampere Linear Regulator Family
... For the fixed Voltage versions the resistive divider is internally set, and the VOUTS pin should be connected to the VOUT pin. The maximum programmed output voltage for the adjustable part is constrained by the 9V absolute rating of the IC (including the charge pump voltage) and its ability to enhan ...
... For the fixed Voltage versions the resistive divider is internally set, and the VOUTS pin should be connected to the VOUT pin. The maximum programmed output voltage for the adjustable part is constrained by the 9V absolute rating of the IC (including the charge pump voltage) and its ability to enhan ...
three-phase bridge rectifiers (b6)
... Among all the line-frequency three-phase rectifiers (M3, M6, B6, ...) the most used is the six-pulses (full) bridge rectifier (B6). As shown in Fig.13.1, its topology consists of three legs with rectifying diodes (uncontrolled rectifiers), with thyristors (phase-controlled rectifiers) or with a diod ...
... Among all the line-frequency three-phase rectifiers (M3, M6, B6, ...) the most used is the six-pulses (full) bridge rectifier (B6). As shown in Fig.13.1, its topology consists of three legs with rectifying diodes (uncontrolled rectifiers), with thyristors (phase-controlled rectifiers) or with a diod ...
MAX3212 +2.7V to +3.6V-Powered, 1µA Supply Current, 3-Driver/5-Receiver, True RS-232 Transceiver _______________General Description
... V.28/V.24 serial interface. True RS-232 levels are maintained across the operating range. A guaranteed data rate of 235kbps provides compatibility with popular software for communicating with personal computers. Supply current is reduced to 1 µA with Maxim’s new AutoShutdown feature. When the MAX321 ...
... V.28/V.24 serial interface. True RS-232 levels are maintained across the operating range. A guaranteed data rate of 235kbps provides compatibility with popular software for communicating with personal computers. Supply current is reduced to 1 µA with Maxim’s new AutoShutdown feature. When the MAX321 ...
Three-Phase Power Quality Analyzer PowerPad Model 3945-B
... Record – Set up and record trend data at selectable rates from one sample/second to one sample every 15 minutes on as many as 22 different variables for all phases. See the recorded data on screen, zoom in and out and scroll the time axis to analyze the data. Power & Energy – Display Watts, VARs and ...
... Record – Set up and record trend data at selectable rates from one sample/second to one sample every 15 minutes on as many as 22 different variables for all phases. See the recorded data on screen, zoom in and out and scroll the time axis to analyze the data. Power & Energy – Display Watts, VARs and ...
mGARD-100 - I-Gard
... connected/bonded. Typically, equipment grounding is provided by means of a ground bus. A solid connection is to be made from terminal 7 of the mGARD-100 to the nearest chassis ground to ensure the relay complies with the specified Electromagnetic compatibility (EMC) standards. If using an external z ...
... connected/bonded. Typically, equipment grounding is provided by means of a ground bus. A solid connection is to be made from terminal 7 of the mGARD-100 to the nearest chassis ground to ensure the relay complies with the specified Electromagnetic compatibility (EMC) standards. If using an external z ...
BD3550HFN
... When EN is OFF, or when UVLO is active, output goes LOW and the output of the NchFET switches OFF. ・EN The EN block controls the regulator’s ON/OFF state via the EN logic input pin. In the OFF position, circuit voltage is maintained at 0μA, thus minimizing current consumption at standby. The FET is ...
... When EN is OFF, or when UVLO is active, output goes LOW and the output of the NchFET switches OFF. ・EN The EN block controls the regulator’s ON/OFF state via the EN logic input pin. In the OFF position, circuit voltage is maintained at 0μA, thus minimizing current consumption at standby. The FET is ...
LTC1443/LTC1444/LTC1445 - Ultralow Power Quad Comparators with Reference
... IN A – (Pin 4): Inverting Input of Comparator A. Input common mode range from V – to V + – 1.3V. Input current typically 10pA at 25°C. IN A + (Pin 5): Noninverting Input of Comparator A. Input common mode range from V – to V + – 1.3V. Input current typically 10pA at 25°C. IN B – (Pin 6): Inverting I ...
... IN A – (Pin 4): Inverting Input of Comparator A. Input common mode range from V – to V + – 1.3V. Input current typically 10pA at 25°C. IN A + (Pin 5): Noninverting Input of Comparator A. Input common mode range from V – to V + – 1.3V. Input current typically 10pA at 25°C. IN B – (Pin 6): Inverting I ...
3.4 Bipolar Transistor Configurations
... connecting terminals with each terminal being given a name to identify it from the other two. These three terminals are known and labelled as the Emitter ( E ), the Base ( B ) and the Collector ( C ) respectively. There are two basic types of bipolar transistor construction, PNP and NPN, which basic ...
... connecting terminals with each terminal being given a name to identify it from the other two. These three terminals are known and labelled as the Emitter ( E ), the Base ( B ) and the Collector ( C ) respectively. There are two basic types of bipolar transistor construction, PNP and NPN, which basic ...
ACS712
... Sensitivity (Sens). The change in sensor output in response to a 1 A change through the primary conductor. The sensitivity is the product of the magnetic circuit sensitivity (G / A) and the linear IC amplifier gain (mV/G). The linear IC amplifier gain is programmed at the factory to optimize the sen ...
... Sensitivity (Sens). The change in sensor output in response to a 1 A change through the primary conductor. The sensitivity is the product of the magnetic circuit sensitivity (G / A) and the linear IC amplifier gain (mV/G). The linear IC amplifier gain is programmed at the factory to optimize the sen ...
LT1942
... Refer to the figure on the first page of this data sheet and the Block Diagram when following the description of the operation of the LT1942. The LT1942 contains four switching regulators. Three switchers are designed to be used as the power supply for driving small to medium sized TFT displays. The ...
... Refer to the figure on the first page of this data sheet and the Block Diagram when following the description of the operation of the LT1942. The LT1942 contains four switching regulators. Three switchers are designed to be used as the power supply for driving small to medium sized TFT displays. The ...
BC847BLP Features Mechanical Data
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
Create smarter, more effi cient white goods An industry-leading portfolio of cost-effective,
... NXP is committed to sustainability and ecofriendly design, and offers a full range of powersaving technologies that increase efficiency and save energy. Use an integrated solution for easy design-in, or create a discrete solution for the lowest cost. ...
... NXP is committed to sustainability and ecofriendly design, and offers a full range of powersaving technologies that increase efficiency and save energy. Use an integrated solution for easy design-in, or create a discrete solution for the lowest cost. ...
Design of Low-Power Adiabatic 32X32 Content Addressable
... enabled by WWL (write word-line) and RWL (read word-line) for writing and comparison operations, respectively. The power supply of CAM cells is connected to a fixed DC voltage (VDD). The CAM array consists of multiple such cells arrayed horizontally and vertically. The WWL and RWL of a row are conne ...
... enabled by WWL (write word-line) and RWL (read word-line) for writing and comparison operations, respectively. The power supply of CAM cells is connected to a fixed DC voltage (VDD). The CAM array consists of multiple such cells arrayed horizontally and vertically. The WWL and RWL of a row are conne ...
PPT: The 607 Standard
... An electrical fault in an electrical cable or equipment may cause chassis or other conductive components to be energized, creating a significant hazard ◦ Electrical shock hazard to people touching the energized component ◦ Equipment damage ◦ Fire ...
... An electrical fault in an electrical cable or equipment may cause chassis or other conductive components to be energized, creating a significant hazard ◦ Electrical shock hazard to people touching the energized component ◦ Equipment damage ◦ Fire ...
2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System
... non-safety-related plant loads during normal and abnormal operations. EPSS divisions are independent and physically separated during normal bus alignments. An alternate feed is provided between EPSS divisions 1 and 2, and between divisions 3 and 4 to provide the normal and standby source of power to ...
... non-safety-related plant loads during normal and abnormal operations. EPSS divisions are independent and physically separated during normal bus alignments. An alternate feed is provided between EPSS divisions 1 and 2, and between divisions 3 and 4 to provide the normal and standby source of power to ...
MAX1562/MAX1562H/MAX1563 Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking General Description
... saving system power. When the short is removed, the switch is reactivated. A fault-blanking feature enables the circuit to ignore momentary faults, such as those caused when hot swapping a capacitive load, preventing false alarms to the host system. Fault blanking also prevents fault signals from be ...
... saving system power. When the short is removed, the switch is reactivated. A fault-blanking feature enables the circuit to ignore momentary faults, such as those caused when hot swapping a capacitive load, preventing false alarms to the host system. Fault blanking also prevents fault signals from be ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.