![RIGOL User’s Guide DP800A Series Programmable Linear DC Power Supply](http://s1.studyres.com/store/data/008854103_1-35e45e6f7a404b877be34396988a6a53-300x300.png)
RIGOL User’s Guide DP800A Series Programmable Linear DC Power Supply
... the instrument only specified by this manual. Use Proper Power Cord. Only the power cord designed for the instrument and authorized for use within the local country could be used. Ground the Instrument. The instrument is grounded through the Protective Earth lead of the power cord. To avoid electric ...
... the instrument only specified by this manual. Use Proper Power Cord. Only the power cord designed for the instrument and authorized for use within the local country could be used. Ground the Instrument. The instrument is grounded through the Protective Earth lead of the power cord. To avoid electric ...
DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
... Note 2: VSS e 0V unless otherwise specified. Note 3: These devices should not be connected to circuits with the power ‘‘ON’’. Note 4: In all cases, there is approximately 5 pF of probe and jig capacitance in the output; however, this capacitance is included in CL wherever it is specified. Note 5: VI ...
... Note 2: VSS e 0V unless otherwise specified. Note 3: These devices should not be connected to circuits with the power ‘‘ON’’. Note 4: In all cases, there is approximately 5 pF of probe and jig capacitance in the output; however, this capacitance is included in CL wherever it is specified. Note 5: VI ...
Magnecraft™ Power Relays
... bb Application Data�����������������������������������������������������������������������������������������������������32 bb Selection Guide�����������������������������������������������������������������������������������������������������34 bb Website Guide������������������������������������ ...
... bb Application Data�����������������������������������������������������������������������������������������������������32 bb Selection Guide�����������������������������������������������������������������������������������������������������34 bb Website Guide������������������������������������ ...
7 Series FPGAs PCB Design and Pin Planning Guide
... PCB Technology Basics Printed circuit boards (PCBs) are electrical systems, with electrical properties as complicated as the discrete components and devices mounted to them. The PCB designer has complete control over many aspects of the PCB; however, current technology places constraints and limits ...
... PCB Technology Basics Printed circuit boards (PCBs) are electrical systems, with electrical properties as complicated as the discrete components and devices mounted to them. The PCB designer has complete control over many aspects of the PCB; however, current technology places constraints and limits ...
Programming manual
... Product stated above, and if the Buyer discovers and notifies AMETEK in writing of any defect in material or workmanship within the applicable warranty period stated above, then AMETEK may, at its option: repair or replace the Product; or issue a credit note for the defective Product; or provide the ...
... Product stated above, and if the Buyer discovers and notifies AMETEK in writing of any defect in material or workmanship within the applicable warranty period stated above, then AMETEK may, at its option: repair or replace the Product; or issue a credit note for the defective Product; or provide the ...
2.5 V/3.3 V, 10-Bit, 2-Port Level Translating, Bus Switch ADG3246
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADG3246 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADG3246 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
Liebert® FS Flywheel Energy Storage System™
... shipment, whichever comes first, provided that startup is performed or supervised by the manufacturer’s service technician and the DC Flywheel has been stored in a suitable environment prior to startup. The DC Flywheel Manufacturer or its certified service partner shall be able to provide service pr ...
... shipment, whichever comes first, provided that startup is performed or supervised by the manufacturer’s service technician and the DC Flywheel has been stored in a suitable environment prior to startup. The DC Flywheel Manufacturer or its certified service partner shall be able to provide service pr ...
uojcourses.awardspace.com
... oppose any significant flow between drain and source. • VDS and VGS have been set at some positive voltage greater than 0V, establishing the D and G at a positive potential with respect to the source • The positive potential at the gate will pressure the holes in the p substrate along the edge of th ...
... oppose any significant flow between drain and source. • VDS and VGS have been set at some positive voltage greater than 0V, establishing the D and G at a positive potential with respect to the source • The positive potential at the gate will pressure the holes in the p substrate along the edge of th ...
Winding insulation and maintenance
... (VPI). While VPI is the preferred method being more reliable, as noted below, other methods also providing satisfactory results and being economical are practised by many manufacturers up to 1000 kW or so. The stator is then cured in an oven as described above. The process of insulation and curing c ...
... (VPI). While VPI is the preferred method being more reliable, as noted below, other methods also providing satisfactory results and being economical are practised by many manufacturers up to 1000 kW or so. The stator is then cured in an oven as described above. The process of insulation and curing c ...
+5V-Powered, Multichannel RS-232 Drivers/Receivers General Description Next-Generation Device Features
... 14-Pin Plastic DIP (derate 10.00mW/°C above +70°C)....800mW 16-Pin Plastic DIP (derate 10.53mW/°C above +70°C)....842mW 20-Pin Plastic DIP (derate 11.11mW/°C above +70°C)....889mW 24-Pin Narrow Plastic DIP (derate 13.33mW/°C above +70°C) ..........1.07W 24-Pin Plastic DIP (derate 9.09mW/°C above +70 ...
... 14-Pin Plastic DIP (derate 10.00mW/°C above +70°C)....800mW 16-Pin Plastic DIP (derate 10.53mW/°C above +70°C)....842mW 20-Pin Plastic DIP (derate 11.11mW/°C above +70°C)....889mW 24-Pin Narrow Plastic DIP (derate 13.33mW/°C above +70°C) ..........1.07W 24-Pin Plastic DIP (derate 9.09mW/°C above +70 ...
Residual Current Protective Devices
... currents. Another version in this device group is the residual current unit (RC unit). The customer can then mount the miniature circuit breaker versions suitable for a particular application (characteristic, rated current, switching capacity) on these RC units. Once assembled, these devices perform ...
... currents. Another version in this device group is the residual current unit (RC unit). The customer can then mount the miniature circuit breaker versions suitable for a particular application (characteristic, rated current, switching capacity) on these RC units. Once assembled, these devices perform ...
Bipolar Junction Transistor
... carriers (i.e. holes in this case), it is forward-biased so far as thermally-generated minority charge carriers (i.e. electrons in this case) are concerned. This current flows even when emitter is disconnected from its dc supply as shown in Fig. 57.10 (a) where switch, S1 is open. It flows in the sa ...
... carriers (i.e. holes in this case), it is forward-biased so far as thermally-generated minority charge carriers (i.e. electrons in this case) are concerned. This current flows even when emitter is disconnected from its dc supply as shown in Fig. 57.10 (a) where switch, S1 is open. It flows in the sa ...
1.1. Modes of Operation
... 60Hz (auto-selectable) using Insulated Gate Bipolar Transistors (IGBT’s) switching at approximately 18kHz, above the audible frequency range, and without low frequency magnetic components. The inverter is of pulse width modulated (PWM) design capable of providing the specified AC output with a very ...
... 60Hz (auto-selectable) using Insulated Gate Bipolar Transistors (IGBT’s) switching at approximately 18kHz, above the audible frequency range, and without low frequency magnetic components. The inverter is of pulse width modulated (PWM) design capable of providing the specified AC output with a very ...
ib0600367engd
... accidentally touch the charged inverter circuits and get an electric shock. z Before wiring or inspection, power must be switched OFF. To confirm that, LED indication of the operation panel must be checked. (It must be OFF.) Any person who is involved in wiring or inspection shall wait for at least ...
... accidentally touch the charged inverter circuits and get an electric shock. z Before wiring or inspection, power must be switched OFF. To confirm that, LED indication of the operation panel must be checked. (It must be OFF.) Any person who is involved in wiring or inspection shall wait for at least ...
PROWatt SW Inverter NA.book
... NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipm ...
... NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipm ...
ADG3245 数据手册DataSheet 下载
... Bus Disable Times. This is the time taken to place the switch in the high impedance OFF state in response to the control signal. It is measured as the time taken for the output voltage to change by V⌬ from the original quiescent level, with reference to the logic level transition at the control inpu ...
... Bus Disable Times. This is the time taken to place the switch in the high impedance OFF state in response to the control signal. It is measured as the time taken for the output voltage to change by V⌬ from the original quiescent level, with reference to the logic level transition at the control inpu ...
PXI Product Guide
... The BIRST tool allows the user to very easily check system switching operation on command. BIRST will identify any relay failures in the switch module and is capable of detecting relays with deteriorating contacts which may indicate they are in the process of failing. ...
... The BIRST tool allows the user to very easily check system switching operation on command. BIRST will identify any relay failures in the switch module and is capable of detecting relays with deteriorating contacts which may indicate they are in the process of failing. ...
Liebert eXL UPS 625-1200kVA Multi-Module Guide
... efficiency when conditions permit by automatically placing the load on the bypass source when the voltage and frequency of that source are within acceptable parameters. The load shall be transferred to the inverter automatically and without interruption should the bypass source be outside of the acc ...
... efficiency when conditions permit by automatically placing the load on the bypass source when the voltage and frequency of that source are within acceptable parameters. The load shall be transferred to the inverter automatically and without interruption should the bypass source be outside of the acc ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.