• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
FSA266 • NC7WB66 Low Voltage Dual SPST FSA26
FSA266 • NC7WB66 Low Voltage Dual SPST FSA26

... 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or 2. A critical component is any component of a life support (b) support or sustain life, or (c) whose failure to perform device or system whose failure to perform can be reasonwhen ...
Complex Circuits 6.0 - University of Michigan–Dearborn
Complex Circuits 6.0 - University of Michigan–Dearborn

... bulbs combined present to the power supply? (This is the equivalent resistance of the combination, which can be calculated here as the supply voltage divided by the current delivered by the supply.) ...
Microwave Oven Technical File
Microwave Oven Technical File

... expectancy could be greatly reduced. Another way in which a magnetron may be damaged is by the use of an excessive amount of metal foil or large metal utensils within the oven cavity. The effect can be that energy is reflected back to the magnetron where it will be dissipated as heat. Small amounts ...
ATX12V Power Supply Design Guide
ATX12V Power Supply Design Guide

... This section briefly summarizes the major changes made to this document that now defines ATX12V power supply. With the move to 12V voltage regulators for the processor, ATX guidelines for 5V as main power are no longer provided. ...
PAM2861 Description Pin Assignments
PAM2861 Description Pin Assignments

... maximum operating voltage and temperature. They also provide better efficiency than silicon diodes, due to a combination of lower forward voltage and reduced recovery time. It is important to select parts with a peak current rating above the peak coil current and a continuous current rating higher t ...
flextec™450 - Red-D
flextec™450 - Red-D

... SAFETY WELDING and CUTTING SPARKS can cause fire or explosion. 6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot materials from welding can easily go through small cracks and op ...
ATX12V Power Supply Design Guide
ATX12V Power Supply Design Guide

AAT3176A 数据资料DataSheet下载
AAT3176A 数据资料DataSheet下载

... lighting modes. Operating at a fast 1MHz switching frequency, the dual-mode (1x/2x) operation of the internal charge pump offers excellent power efficiency for both flash and movie modes and combined with a low external parts count (one 1μF flying capacitors and small bypass capacitors at VIN and OU ...
High-Performance Adaptive Perturb and Observe MPPT Technique
High-Performance Adaptive Perturb and Observe MPPT Technique

AP7167  1.2A LOW DROPOUT REGULATOR WITH POK Description
AP7167 1.2A LOW DROPOUT REGULATOR WITH POK Description

... capacitors ≥ 4.7μF. The device is also stable with multiple capacitors in parallel, which can be of any type of value. Additional capacitance helps to reduce undershoot and overshoot during transient. This capacitor should be placed as close as possible to OUT and GND pins for optimum performance. ...
M  HIGH-VOLTAGE EQUIPMENT Read this entire manual before operating.
M HIGH-VOLTAGE EQUIPMENT Read this entire manual before operating.

4-20mA Current Transmitters with Sensor Excitation and Linearization
4-20mA Current Transmitters with Sensor Excitation and Linearization

... sources while the XTR114 has two 100µA sources for RTD excitation. Versatile linearization circuitry provides a 2nd-order correction to the RTD, typically achieving a 40:1 improvement in linearity. Instrumentation amplifier gain can be configured for a wide range of temperature or pressure measureme ...
Amprobe Amprobe CT-326-C Current Tracer Manual
Amprobe Amprobe CT-326-C Current Tracer Manual

... IMPORTANT: Since the load current on the conductors supplying power to the transmitter flows in opposite directions on the “hot” and neutral wires, the magnetic field surrounding these conductors radiates in the opposite direction. (See Fig. 6). Therefore, when the “hot” and neutral wires are within ...
S280-70-2_10000
S280-70-2_10000

... for configuring user-selected inputs and outputs, configurable event and alarm data, and selectable communication points for serial communication. ...
TwecoAEB Inverter Arc Welder 300 GMS CC-CV 0-2371_AA
TwecoAEB Inverter Arc Welder 300 GMS CC-CV 0-2371_AA

... Remove all combustibles from working area or provide a fire watch. Avoid paint spray rooms, dip tanks, storage areas, ventilators. Move work to an area free of combustibles if possible. If work cannot be moved, move combustibles at least 35 ft (10.7 m) away from sparks and heat or protect against ig ...
Advantages of Solid-State Relays Over Electro
Advantages of Solid-State Relays Over Electro

... state) for 4-pin SSRs. The rest of the SSR product line is rated at either 3750 or 5,000 Vrms for 60 seconds. With EMRs, the input to output isolation is most often referred to as insulation resistance. The term defines the resistance value between all isolated conducting sections of the relay. This ...
AAT3603A 数据资料DataSheet下载
AAT3603A 数据资料DataSheet下载

... current, charge termination current, and recharge voltage are programmable with an external resistor and/or by a standard I2C interface. The step-down DC/DC converter is integrated with internal compensation and operates at a switching frequency of 1.5MHz, thus minimizing the size of external compon ...
BU2098F
BU2098F

... Power dissipation(total loss) indicates the power that can be consumed by IC at TA=25°C(normal temperature). IC is heated when it consumed power, and the temperature of IC chip becomes higher than ambient temperature. The temperature that can be accepted by IC chip depends on circuit configuration, ...
Computer-8d -96 Computer-8d
Computer-8d -96 Computer-8d

... (I/0) or any equivalent element to connect (ON) or disconnect (OFF) the instrument from the power supply network. Power supply circuit as well as connections to different relays will be wired with cables of a minimum cross-section of 2.5 mm2. The circuit from de current transformer secondary will be ...
Three-phase Sensorless BLDC Motor Control Kit with the This
Three-phase Sensorless BLDC Motor Control Kit with the This

... • DC bus over-voltage, under-voltage, over-current, and overload protection ...
P10345 – Automated TFT Noise Characterization Platform Kendell
P10345 – Automated TFT Noise Characterization Platform Kendell

... objective of this analysis is to determine the contribution of each noise source to the current noise at the channel. Results of the analysis show that all sources add negligible noise compared to the intrinsic JFET channel noise, In,ch. Since 1/f noise is typically a very low frequency phenomenon, ...
Common Emitter(CE)
Common Emitter(CE)

... – It can be seen that IC flows even when VCB is zero – It is due to the fact that electrons are being injected into base due to forward biased E-B junction and are collected by collector due to action of internal junction voltage at C-B junction – Another important feature is that a small amount of ...
HMC536MS8G 数据资料DataSheet下载
HMC536MS8G 数据资料DataSheet下载

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries

... where W is the calorific value (J), V is the arc voltage (V), I is the arc current (A) and Q is the total amounts of electric charges (C). When arc voltages are assumed to be 1000 V/m and the total amount 75C of electric charges, the quantity of heat of 90 kJ/m will occur inside a blade. We can calc ...
MAX1515 Low-Voltage, Internal Switch, Step-Down/DDR Regulator General Description
MAX1515 Low-Voltage, Internal Switch, Step-Down/DDR Regulator General Description

... and achieves efficiencies as high as 95%. The MAX1515 can be configured as a DDR regulator, producing an output that is exactly half the memory supply rail. The input of the power stage can be taken from the memory supply rail itself, resulting in an efficient power supply that returns the energy to ...
< 1 ... 168 169 170 171 172 173 174 175 176 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report