• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
assign3
assign3

... transistors must be 1.3 V about VSS, since the source of the top left transistor is at 0.65 V above VSS. The top right transistor’s source must also be around 0.65 V to maintain the same Vgs voltage. Thus, the output drain can be no more than Vt volts below the gate, and so must be 1.3 V-0.5 V=0.8 V ...
Lab 2: Circuit Simulation
Lab 2: Circuit Simulation

2. electrostatic type voltmeter
2. electrostatic type voltmeter

... In thermocouple temperature sensor, the temperature of hot junction is measured in respect of cold junction of vise varsa. The thermoelectric potential is generated in a thermocouple instrument is in range of μV. Hence, the voltmeter connected to measure the thermoelectric potential is extremely sen ...
HMC855LC5
HMC855LC5

... the data into other devices. The demux is DC coupled supporting broadband operation. All clock and data inputs to the HMC855LC5 are CML and terminated on-chip with 50 Ohms to the positive supply, GND, and may be DC or AC coupled. The differential outputs are source terminated to 50 Ohms and may also ...
Which Transformer?
Which Transformer?

... There are three basic styles of transformers used in the suspended scaffold industry; buck/boost, step-up, and step-down. Buck/Boost transformers are the most common transformers used in suspended scaffolding. As the name implies these transformers can have two different uses. “Bucking” power is don ...
student`s book - Macmillan Education South Africa
student`s book - Macmillan Education South Africa

JU2216461651
JU2216461651

... produced by telecom equipment in power distribution networks. Therefore, the functionalities of the conventional DSTATCOM should be increased to mitigate the aforementioned PQ problems and to supply the dc loads from its dc link as well. The load sharing by the ac and dc bus depends upon the design ...
ZXLD383 Summary Features Application Pin Assignments Typical
ZXLD383 Summary Features Application Pin Assignments Typical

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0

Slash Voltage Rating
Slash Voltage Rating

... the two ratings is for overcurrents at line-to-ground voltages, intended to be cleared by one pole of the device. The higher of the two ratings is for overcurrents at line-to-line voltages, intended to be cleared by two or three poles of the circuit breaker or other mechanical overcurrent device. Sl ...
download
download

... remains OFF until VEB = VP , where VP is known as the peak-point voltage. As soon as VEB tends to go above VP , the UJT will turn ON if and only if the emitter current I E ≥ I P , where I P is the peak-point emitter current. Consider this as the condition for the device to turn on. As soon as the em ...
IM-103 Rebuild Kit
IM-103 Rebuild Kit

... which affects both the brightness and focus ability of these models. This kit of parts contains the typical parts necessary to rebuild the High Voltage portion of your monitor scope. The resistors used in this rebuild kit are of the metal film type that will not drift over time. The capacitors are e ...
FSFR2100 — Fairchild Power Switch (FPS™) for Half-Bridge Resonant Converters
FSFR2100 — Fairchild Power Switch (FPS™) for Half-Bridge Resonant Converters

... Abnormal Over-Current Protection (AOCP): If the secondary rectifier diodes are shorted, large current with extremely high di/dt can flow through the MOSFET before OCP or OLP is triggered. AOCP is triggered without shutdown delay when the sensing pin voltage drops below -0.9V. This protection is latc ...
CE8809 Series
CE8809 Series

... voltage), VOUT will be equal to VSS until VDD reaches the +VDET level. 5 . Although VDD will rise to a level higher than +VDET, VOUT maintains ground voltage level via the delay circuit. ...
- Setsquare
- Setsquare

... switches off lighting whenever ambient light level rises above a chosen level. As the daylight level reduces, SensaLUX will automatically switch lighting on at the preset level. To avoid switching on and off during short bright or cloudy periods the unit incorporates an adjustable time delay. A two ...
AC to DC Converter (Rectifier)
AC to DC Converter (Rectifier)

... The load is fed via a thyristor in each positive cycle of voltages v1 and v2 and the load current returns via the neutral N. With reference in picture bisaides, thyristor T1 can be fired into the ON state at any time provided that voltage vT1 > 0. The firing pulses are delayed by an angle a with res ...
Li, W., and D.J. Perreault, “FITMOS Modeling and On-resistance AC Characteristic Evaluation,” 2010 IEEE Energy Conversion Congress and Exposition , pp. 378-385, Sept. 2010.
Li, W., and D.J. Perreault, “FITMOS Modeling and On-resistance AC Characteristic Evaluation,” 2010 IEEE Energy Conversion Congress and Exposition , pp. 378-385, Sept. 2010.

... a time period after the device is turned on. As the drainsource current Ids that is carried is increased to a certain level (e.g., by adjusting load resistance or input voltage at constant duty ratio), the drain-source voltage of FITMOS does not drop quickly to the normal low level (Rds-on*Ids) that ...
Hybrid Converter Topology For Power Factor
Hybrid Converter Topology For Power Factor

... This paper deals with a hybrid converter topology power factor correction (PFC) for AC drives which is fed through a diode bridge rectifier from a single phase AC mains. In this project both buck and boost converter topologies are combined together and operated alternatively according to the rectifi ...
Modular multilevel converters with integrated batteries energy storage
Modular multilevel converters with integrated batteries energy storage

EMI4193 数据资料DataSheet下载
EMI4193 数据资料DataSheet下载

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
university of california at berkeley
university of california at berkeley

... Instruction For this lab, you may consult the professor, the TAs, the textbook, and any other inanimate objects, with the exception of your peers' lab reports, for reference. You may obtain data in pairs, but must submit your own written report. Be concise. ...
03_Op_Amps-JAGv6
03_Op_Amps-JAGv6

MAX761/MAX762 12V/15V or Adjustable, High-Efficiency, Low I , Step-Up DC-DC Converters
MAX761/MAX762 12V/15V or Adjustable, High-Efficiency, Low I , Step-Up DC-DC Converters

... switch either (1) stays off if the output is in regulation, or (2) turns on again if the output is out of regulation. The MAX761/MAX762 also limit the peak inductor current, allowing the devices to run in continuous-conduction mode (CCM) and maintain high efficiency with heavy loads (Figure 4a). Thi ...
CIRCU ITS GALORE !
CIRCU ITS GALORE !

... potential difference will be after you remove the indicated resistor. Use the simulator to check your result. Explain this result. ...
Transformers - OpenStax CNX
Transformers - OpenStax CNX

... The number of loops in the secondary is small, as expected for a step-down transformer. We also see that a small input current produces a larger output current in a step-down transformer. When transformers are used to operate large magnets, they sometimes have a small number of very heavy loops in t ...
< 1 ... 430 431 432 433 434 435 436 437 438 ... 947 >

Electrical ballast



An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report