* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download - Setsquare
History of electric power transmission wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electrical ballast wikipedia , lookup
Voltage optimisation wikipedia , lookup
Mains electricity wikipedia , lookup
Control theory wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electrical substation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Distributed control system wikipedia , lookup
Buck converter wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Rectiverter wikipedia , lookup
Control system wikipedia , lookup
Resilient control systems wikipedia , lookup
Light detection The smart lighting control The SensaLUX range of products saves electricity by automatically switching lights off when it is bright and switching lights on when it is dull or dark. ■ ■ ■ ■ ■ ■ Fully automatic lighting control Dramatic reductions in electricity use Helps reduce global CO2 emissions Low profile detectors Self-contained or modular Simple to install Self-contained systems The LLS1 (surface mounted) and LLS2 (recess mounted) are self-contained photocell detection and switching units. They respond to ambient light level and automatically switch the controlled load on and off as light level changes through the day. The sensors have an integral rather than remote photocell so are well suited to localised control. How it works 82mm Both units are microprocessor controlled. However, operation of each is slightly different. LLS1 –incorporates two separate controls for setting light levels ‘on’ and ‘off’. LLS2 –incorporates one control to set the ‘on’ light level. The unit automatically sets the ‘off’ level. 80mm 22mm 82mm 80mm 22mm Surface mounting box for LLS1 Surface mounted sensor LLS1 SB Location The LLS sensors are best located where they have a view of the representative light level, i.e. in an area influenced by both ambient and artificial light. 72mm 83mm 68mm 146mm 35mm Recess mounting patress for LLS1 Recess mounted sensor LLS2 RB Specification – self-contained 240V 50Hz LLS1 100m Supply voltage or LLS2 Timer Fixed 30 seconds Colour White Photocell range 50-1500 lux ± 10% mm 89 Switching capacity8A or 8 HF ballasts L Contactor N CE16 S/L Switched live Live Neutral m 171 Key-operated override switch Light switch Lighting load (up to 8A) Wiring diagram showing override options Modular systems Typical electrical diagram SX2 The modular system comprises of a controller mounted at a suitable electrical distribution point, a photocell (internal or external) connected via low voltage wiring and, optionally, a clock for timed control and a contactor for switching larger loads. E N L COM A N/O A COM B N/O B Switch Switch Photocell Volt free contacts Photocell override SX1/2 only Location The control unit is best located adjacent to the load to be controlled. The photocell is available in two versions: recessed, ceiling mounted (PP) or surface mounted in a weatherproofed housing (SL8P) for industrial or external mounting. Load A each up to 8A inductive or resistive Load B Note: Wiring to sensor should be via twin screened cable How it works 47mm 36mm 80mm The SensaLUX SX1 is a microprocessor control which automatically switches off lighting whenever ambient light level rises above a chosen level. As the daylight level reduces, SensaLUX will automatically switch lighting on at the preset level. To avoid switching on and off during short bright or cloudy periods the unit incorporates an adjustable time delay. A two relay version is available (SX2) with independently adjustable on and off levels. 47mm Photocell recess Photocell override PP (SX1/2 ONLY) POB Shop fascia system 60mm 82mm A special system for shop fascia control is available. Offering the facilities of the system detailed above, the control SX1/2 also accepts input from a momentary-make override switch. If the override switch is located in the fascia, the lights can be brought on for maintenance when the photocell has switched them off. Specification – modular system 80mm PRESS PHOTOCELL OVERRIDE 95mm 23mm 9mm 80mm 18mm Surface mounting box for PP Photocell rugged/ external PSB SL8P Supply voltageControl unit 240V 50Hz Detector: 5V dc 100m Switching capacity8A or maximum 8 HF ballasts On: 30 seconds mm 89 TimerOff: Selectable: 2, 4, 8, 16 minutes 85mm m 171 30mm 147mm Photocell range 50-1500 lux ± 10% Contactor Control units Colour Control unit white CE16 3 pole 16A Single Relay SX1 Dual Relay SX2 Single Relay SX1/2 Photocell (recess) PP White Photocell (surface) SL8P Grey 65mm (Fascia) 102mm Time ClockAuto Summer/Winter/ Time clock 7 day/Holiday override 65mm SXT technology that’s light years ahead Setsquare products Setsquare’s range of energy conservation products and services includes: ■ Lighting controls ■ Marshalling boxes ■ Occupancy sensors ■ High bay lighting ■ Lighting dimming systems ■ Scene setting Time delay switches ■ Heating controls ■ ■ Wash-room flush controls Setsquare Limited Valley Industries, Hadlow Road Tonbridge, Kent, UK, TN11 0AH Designed and produced by The Upper Room 020 8406 1010 05/10 All Setsquare products are designed, manufactured, supplied and installed to BS EN ISO 9001: 2000 Due to the policy of continual development, Setsquare Limited reserve the right to alter specifications without prior notice. tel +44 (0)1732 851 888 fax +44 (0)1732 851 853 e-mail [email protected] web www.setsquare.co.uk