HMC427LP3 / 427LP3E
... General Description The HMC427LP3 & HMC427LP3E are low loss broadband positive control transfer switches in leadless surface mount packages. Covering DC to 8 GHz, this switch offers high isolation and low insertion loss. The switch operates using a positive control voltage of 0/+5V and requires a fi ...
... General Description The HMC427LP3 & HMC427LP3E are low loss broadband positive control transfer switches in leadless surface mount packages. Covering DC to 8 GHz, this switch offers high isolation and low insertion loss. The switch operates using a positive control voltage of 0/+5V and requires a fi ...
WECC-0100 TPL-001-WECC-CRT-3 Response to Comment
... Requirement WR1 is designed to set the minimum threshold at which the Transmission Planner (TP) and the Planning Coordinator (PC) will examine their own systems. For purposes of examining their own systems, the TP and PC can use a more stringent set of criteria than stated in Requirement WR1; howeve ...
... Requirement WR1 is designed to set the minimum threshold at which the Transmission Planner (TP) and the Planning Coordinator (PC) will examine their own systems. For purposes of examining their own systems, the TP and PC can use a more stringent set of criteria than stated in Requirement WR1; howeve ...
Power Supply Unit: Transformer Skill: Diagnosing a transformer that
... Identification and Diagnosis A transformer is used in many electronic instruments. Sometimes, equipment is used in a different country than it was manufactured for. External transformers are used to adapt the equipment to the mains voltage difference. External transformers are also called wall tran ...
... Identification and Diagnosis A transformer is used in many electronic instruments. Sometimes, equipment is used in a different country than it was manufactured for. External transformers are used to adapt the equipment to the mains voltage difference. External transformers are also called wall tran ...
AD8295 数据手册DataSheet 下载
... The AD8295 includes a high performance, programmable gain instrumentation amplifier. Gain is set from 1 to 1000 with a single resistor. The low noise and excellent common-mode rejection of the AD8295 enable the part to easily detect small signals even in the presence of large common-mode interferenc ...
... The AD8295 includes a high performance, programmable gain instrumentation amplifier. Gain is set from 1 to 1000 with a single resistor. The low noise and excellent common-mode rejection of the AD8295 enable the part to easily detect small signals even in the presence of large common-mode interferenc ...
R225-01-1
... increases linearly as the individual range of regulation of each voltage regulator increases. When the voltage regulators are all set at the same extreme tap position, 16L or 16R, there is a maximum 4° to 6° shift in the phase angle. ...
... increases linearly as the individual range of regulation of each voltage regulator increases. When the voltage regulators are all set at the same extreme tap position, 16L or 16R, there is a maximum 4° to 6° shift in the phase angle. ...
Multi-Cell Lithium Ion Battery Management System
... a battery management system. In order to focus more on the battery management system, and to prevent from electric shock due to high voltage, we are scaling down the power supply from using a 120V AC outlet to four series connected DC power supplies that will output 65 VDC and up to 3 Amp for the sy ...
... a battery management system. In order to focus more on the battery management system, and to prevent from electric shock due to high voltage, we are scaling down the power supply from using a 120V AC outlet to four series connected DC power supplies that will output 65 VDC and up to 3 Amp for the sy ...
ADL5310 数据手册DataSheet 下载
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
FPF2223-FPF2225 Integrated Load Switch with Adjustable High Precision Current Limit FP F2
... P (Max) = VIN (MAX) * ILIM (MAX) = 5.5 * 0.693 = 3.8W This large amount of power will activate the thermal shutdown and the part will cycle in and out of thermal shutdown so long as the ON pin is active and the short is present. ...
... P (Max) = VIN (MAX) * ILIM (MAX) = 5.5 * 0.693 = 3.8W This large amount of power will activate the thermal shutdown and the part will cycle in and out of thermal shutdown so long as the ON pin is active and the short is present. ...
Physics 212 Sample Question Bank II 2011
... in series to a battery. The quantity that is the same for the two wires is: (A) the potential difference across the length of each segment. (B) the current in each segment. (C) the current density in each segment. (D) the electric field in each segment. (E) the electron drift velocity in each segmen ...
... in series to a battery. The quantity that is the same for the two wires is: (A) the potential difference across the length of each segment. (B) the current in each segment. (C) the current density in each segment. (D) the electric field in each segment. (E) the electron drift velocity in each segmen ...
Power MOSFET 9 A, 52 V, N-Channel, Logic Level
... in the accompanying graph (Figure 12). Maximum energy at currents below rated continuous ID can safely be assumed to equal the values indicated. ...
... in the accompanying graph (Figure 12). Maximum energy at currents below rated continuous ID can safely be assumed to equal the values indicated. ...
FSB50660SF, FSB50660SFT Motion SPM 5 SuperFET Series
... 2. RC-coupling (R5 and C5, R4 and C6) and C4 at each input of Motion SPM® 5 product and MCU are useful to prevent improper input signal caused by surge-noise. 3. The voltage-drop across R3 affects the low-side switching performance and the bootstrap characteristics since it is placed between COM and ...
... 2. RC-coupling (R5 and C5, R4 and C6) and C4 at each input of Motion SPM® 5 product and MCU are useful to prevent improper input signal caused by surge-noise. 3. The voltage-drop across R3 affects the low-side switching performance and the bootstrap characteristics since it is placed between COM and ...
IOSR Journal of Electrical and Electronics Engineering PP 01-08 www.iosrjournals.org
... to high fault currents. To avoid saturation, CTs are designed to operate at load currents on the lower portion of the magnetizing branch of V-I curve‟s linear region. It is desirable that CT‟s operate on the linear region without exceeding the saturation voltage even for fault currents. [3][7] Capac ...
... to high fault currents. To avoid saturation, CTs are designed to operate at load currents on the lower portion of the magnetizing branch of V-I curve‟s linear region. It is desirable that CT‟s operate on the linear region without exceeding the saturation voltage even for fault currents. [3][7] Capac ...
MAX16826 Programmable, Four-String HB LED Driver with Output-Voltage Optimization and Fault Detection
... a switching regulator controller, a 4-channel linear current sink driver, an analog-to-digital converter (ADC), and an I2C interface. The IC is designed to withstand automotive load dump transients up to 40V and can operate under cold crank conditions. The MAX16826 contains a current-mode PWM switch ...
... a switching regulator controller, a 4-channel linear current sink driver, an analog-to-digital converter (ADC), and an I2C interface. The IC is designed to withstand automotive load dump transients up to 40V and can operate under cold crank conditions. The MAX16826 contains a current-mode PWM switch ...
ZRC330
... precision micropower voltage reference of 3.3 volts. The device is available in a small outline surface mount package, ideal for applications where space saving is important. The ZRC330 design provides a stable voltage without an external capacitor and is stable with capacitive loads. The ZRC330 is ...
... precision micropower voltage reference of 3.3 volts. The device is available in a small outline surface mount package, ideal for applications where space saving is important. The ZRC330 design provides a stable voltage without an external capacitor and is stable with capacitive loads. The ZRC330 is ...
User's Manual PQP-A Energotester Edition 1
... electrical values and power quality parameters (hereinafter referred to as PQP) in power networks . The UM describes their operation, maintenance, transportation, storage, and manufacturer's warranty conditions. The UM also includes information about the calibration procedure, packing form and accep ...
... electrical values and power quality parameters (hereinafter referred to as PQP) in power networks . The UM describes their operation, maintenance, transportation, storage, and manufacturer's warranty conditions. The UM also includes information about the calibration procedure, packing form and accep ...
µ OPA348 OPA2348 OPA4348
... NOTES: (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only. Functional operation of the device at these conditions, or beyond the specified operating conditions, is not ...
... NOTES: (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only. Functional operation of the device at these conditions, or beyond the specified operating conditions, is not ...
New Real time Voltage Stability Indicators Based on Phasor
... Computing uncertainty of the equivalent grid parameters depending on the identification method, and their high sensitivity to small changes of local measurements at fast sampling rate; Computing time which often does not allow enough speed for real-time applications; The significant performanc ...
... Computing uncertainty of the equivalent grid parameters depending on the identification method, and their high sensitivity to small changes of local measurements at fast sampling rate; Computing time which often does not allow enough speed for real-time applications; The significant performanc ...
Electrical ballast
An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.