• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
1969 , Volume , Issue June-1969
1969 , Volume , Issue June-1969

... Instruments that perform a simple pulse echo test have been used by the power utilities for fault locating on long lines, typically greater than 1 mile. These instruments are basically low frequency real time oscilloscopes, capable of isolating a fault to not much better than 20 feet on the shortest ...
as a PDF
as a PDF

Optimal Efficiency Controller of AC Drive System
Optimal Efficiency Controller of AC Drive System

... [17] Rateb Issa ,Zeid Hijazin,Electric Motors Drive, AlMujtama’ Al-Arabi Publisher,Amman,Jordan, 2007. [18] Hussein Sarhan, Rateb Issa and Mohammad Alia, Optimal Power Factor Control of Three-Phase Induction Motor Drives Using PIC-Microcontroller, International Review of Automatic Control,2012, Vol. ...
Thermal Management
Thermal Management

... Low Power, Rail-to-Rail Input/Output, Single-Supply Operational Amplifiers Microchip’s op amp portfolio offers over 100 unique products spanning bandwidths from 9 kHz up to 60 MHz. All of Microchip’s op amps are designed on a low power CMOS process and support operating voltages as low as 1.4V. All ...
A TWO-STAGE 1 kW SOLID-STATE LINEAR AMPLIFIER INTRODUCTION GENERAL DESIGN CONSIDERATIONS
A TWO-STAGE 1 kW SOLID-STATE LINEAR AMPLIFIER INTRODUCTION GENERAL DESIGN CONSIDERATIONS

... output. The type used here as the input transformer exhibits good broad band characteristics with a convenient physical design. However, according to the low frequency minimum inductance formula presented earlier in connection with T2, the initial permeability required would be nearly 3000, with the ...
Fault Diagnosis on Medium Voltage (MV) Electric Power Distribution
Fault Diagnosis on Medium Voltage (MV) Electric Power Distribution

UPS-1500-S-1U
UPS-1500-S-1U

... electrical conditions of Military/Aerospace applications. SynQor’s UPS incorporates field proven high efficiency designs and rugged packaging technologies. This UPS will accept a wide range of input voltage and frequency values while delivering a well-conditioned AC output to the load. The use of li ...
TL circuits with half- and quarter
TL circuits with half- and quarter

... We have replaced the short termination of the previous lecture with an arbitrary load impedance ZL = RL + jXL. In this lecture we will discuss sinusoidal steady-state TL circuit problems having arbitrary reactive loads but with line lengths l constrained to be integer multiples of λ4 (at the operati ...
DUAL LOAD WIRING SOLUTION SIMPLE, QUICK AND ERROR-FREE INSTALLATION FOR DUAL LOAD APPLICATIONS
DUAL LOAD WIRING SOLUTION SIMPLE, QUICK AND ERROR-FREE INSTALLATION FOR DUAL LOAD APPLICATIONS

... Integra DL1 Dual Load Digital Metering System Designed, developed and manufactured in the UK, the Integra DL1 digital metering system is ideal for low voltage applications and provides a cost effective way of metering Power and Lighting boards in a single meter. It also has the programmable option ...
EQ-K e4
EQ-K e4

... wave form even of high harmonics. Error of indication may occur for extreme wave forms (e.g. phase gating controls) and / or frequencies above 100 Hz. These meters are not suitable for use with shunts or tachogenerators due to their high power consumption. The K-series meters offer application-orien ...
Dual 160 MHz Rail-to-Rail Amplifier AD8042
Dual 160 MHz Rail-to-Rail Amplifier AD8042

... converters (ADCs). ...
Power Management Solutions for Infiniband SM I/O Modules
Power Management Solutions for Infiniband SM I/O Modules

DN05041 - 85-115 Vac Buck LED Driver
DN05041 - 85-115 Vac Buck LED Driver

J.M. Rivas, T.A. Keim, and D.J. Perreault, “Performance Improvement of Alternators with Switched-Mode Rectifiers,” IEEE Transactions on Energy Conversion , Vol. 19, No. 3, Sept. 2004, pp. 561-568.
J.M. Rivas, T.A. Keim, and D.J. Perreault, “Performance Improvement of Alternators with Switched-Mode Rectifiers,” IEEE Transactions on Energy Conversion , Vol. 19, No. 3, Sept. 2004, pp. 561-568.

... necessary. As of today, Lundell-type alternators with diode rectifiers are almost universally used. The alternators are designed to operate optimally at idle speed, thus maximizing output power delivery at the speed providing the least generated power. At higher speeds, the power capabilities of the ...
CJ5853DC DFNWB3
CJ5853DC DFNWB3

... Peak Repetitive Reverse Voltage ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... improvements in terms of speed, density and cost have kept constant for more than 30 years. By the end of 2004, “System-on-Chips” with about 300,000,000 transistors will be fabricated on a single piece of silicon no larger than 2x2 cm. In this paper present some information illustrating the technolo ...
FSD176MRT Green-Mode Fairchild Power Switch (FPS™) Features
FSD176MRT Green-Mode Fairchild Power Switch (FPS™) Features

... However, even when the SMPS is in normal operation, the overload protection circuit can be triggered during load transition. To avoid this undesired operation, the overload protection circuit is designed to trigger only after a specified time to determine whether it is a transient situation or a tru ...
MAX78700 Multichannel, Isolated, Precision ADC General Description Benefits and Features
MAX78700 Multichannel, Isolated, Precision ADC General Description Benefits and Features

... create the VCC voltage. A 2.5V regulator block powers all the digital blocks of the chip except the PLL and ISO_INT, which are powered by VCC. ...
A Low-Power Battery-Free Tag for Body Sensor Networks
A Low-Power Battery-Free Tag for Body Sensor Networks

... of the amplifier (minus the capacitors) to determine the quiescent value. There are two event types: positive-going, in which the output voltage is larger than its quiescent value by Vth or more, and negative-going, in which it is smaller. The smallest input amplitude that triggers a spike decreases ...
Silicon Steroids for the Stamp Help Your Projects Heft Big Loads
Silicon Steroids for the Stamp Help Your Projects Heft Big Loads

AD8210 数据手册DataSheet 下载
AD8210 数据手册DataSheet 下载

... The AD8210 is comprised of two main blocks, a differential amplifier and an instrumentation amplifier. A load current flowing through the external shunt resistor produces a voltage at the input terminals of the AD8210. The input terminals are connected to the differential amplifier (A1) by R1 and R2 ...
Full Text - ARPN Journals
Full Text - ARPN Journals

... Distortion) of 65% and power factor as low as 0.8. So the power factor is corrected using the PFC converters. Both continuous and discontinuous modes of the converters are discussed and the discontinuous mode of conduction is best suited for the low power applications. Since the discontinuous conduc ...
DARLINGTON TRANSISTOR ARRAYS
DARLINGTON TRANSISTOR ARRAYS

... transistor arrays. Each consists of seven npn Darlington pairs that feature high-voltage outputs with common-cathode clamp diodes for switching inductive loads. The collector-current rating of a single Darlington pair is 500 mA. The Darlington pairs may be paralleled for higher current capability. A ...
MK3724
MK3724

... 3.3 V input voltage to cause the output clocks to vary by ±115 ppm. Using IDT’s analog/digital Phase-Locked Loop (PLL) techniques, the device uses an inexpensive 27 MHz pullable crystal input to produce a reference output and a selectable audio clock. ...
Document
Document

... been carried out. If a piece of plastic is placed within the cavity, then, according to formula (1), the resonant frequency will change its magnitude. And, the bigger the field at the position of the probe, the bigger the frequency shift. Hence, the space profile of the microwave electric field with ...
< 1 ... 548 549 550 551 552 553 554 555 556 ... 1052 >

Power inverter



A power inverter, or inverter, is an electronic device or circuitry that changes direct current (DC) to alternating current (AC).The input voltage, output voltage and frequency, and overall power handling depend on the design of the specific device or circuitry. The inverter does not produce any power; the power is provided by the DC source.A power inverter can be entirely electronic or may be a combination of mechanical effects (such as a rotary apparatus) and electronic circuitry.Static inverters do not use moving parts in the conversion process.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report