
AN90 - Current Sources for Fiber Optic Lasers
... An unprotected current source’s output rises to maximum voltage if the load is disconnected. This circumstance can lead to “hot plugging” the laser, a potentially destructive event. Intermittent laser connections can produce similar undesirable results. The current source output should latch off if ...
... An unprotected current source’s output rises to maximum voltage if the load is disconnected. This circumstance can lead to “hot plugging” the laser, a potentially destructive event. Intermittent laser connections can produce similar undesirable results. The current source output should latch off if ...
An Ultra-Low-Power Pulse Oximeter Implemented with an Energy-Efficient Transimpedance Amplifier
... The idea behind the operation of pulse oximeters is that hemoglobin changes color from dark red to bright red when oxygenated and reduces its absorption of red light. Hence, if we shine red LED light at 660 nm through one side of a patient’s finger and measure the transmitted light on the other side ...
... The idea behind the operation of pulse oximeters is that hemoglobin changes color from dark red to bright red when oxygenated and reduces its absorption of red light. Hence, if we shine red LED light at 660 nm through one side of a patient’s finger and measure the transmitted light on the other side ...
Solid-state Timer - OMRON Industrial Automation
... Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: Ag-alloy H3CR-A8E 5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1) Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: AgSnIn • Transistor output: Open col ...
... Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: Ag-alloy H3CR-A8E 5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1) Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: AgSnIn • Transistor output: Open col ...
RE1E002SP
... Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fi ...
... Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fi ...
Evaluates: MAX8858 MAX8858 Evaluation Kit General Description Features
... jumper JU11. See Table 1 for jumper settings. 2) Preset the power supply to 2.4V. Turn the power supply off. Caution: Do not turn on the power supply until all connections are completed. 3) Connect the 2.4V power supply across the VBATT and GND pads. 4) Turn on the 2.4V power supply. 5) Verify that ...
... jumper JU11. See Table 1 for jumper settings. 2) Preset the power supply to 2.4V. Turn the power supply off. Caution: Do not turn on the power supply until all connections are completed. 3) Connect the 2.4V power supply across the VBATT and GND pads. 4) Turn on the 2.4V power supply. 5) Verify that ...
THS1031 数据资料 dataSheet 下载
... The THS1031 is a CMOS, low-power, 10-bit, 30 MSPS analog-to-digital converter (ADC) that can operate with a supply range from 3 V to 5.5 V. The THS1031 has been designed to give circuit developers flexibility. The analog input to the THS1031 can be either single-ended or differential. This device ha ...
... The THS1031 is a CMOS, low-power, 10-bit, 30 MSPS analog-to-digital converter (ADC) that can operate with a supply range from 3 V to 5.5 V. The THS1031 has been designed to give circuit developers flexibility. The analog input to the THS1031 can be either single-ended or differential. This device ha ...
2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System
... cooling, and preventing a significant release of radioactive material to the environment. The EPSS distributes power to safety-related and non-safety-related plant loads during normal and abnormal operations. EPSS divisions are independent and physically separated during normal bus alignments. An al ...
... cooling, and preventing a significant release of radioactive material to the environment. The EPSS distributes power to safety-related and non-safety-related plant loads during normal and abnormal operations. EPSS divisions are independent and physically separated during normal bus alignments. An al ...
Notional System Report Two - Rev18
... Jonathan Crider, Purdue University Hamid Ouroua, University of Texas at Austin Enrico Santi, University of South Carolina Scott Sudhoff, Purdue University ...
... Jonathan Crider, Purdue University Hamid Ouroua, University of Texas at Austin Enrico Santi, University of South Carolina Scott Sudhoff, Purdue University ...
The Power Quality of Wind Turbines
... networks. However, the integration of wind power into distribution networks will transform them from being passive to active networks. Various published work is related to this subject; [2 – 10] have shown that generators embedded into distribution networks can affect operation in such networks in ...
... networks. However, the integration of wind power into distribution networks will transform them from being passive to active networks. Various published work is related to this subject; [2 – 10] have shown that generators embedded into distribution networks can affect operation in such networks in ...
View Attachment - Northeast Power Coordinating Council
... These alarms should be monitored in a manner consistent with established practice, which could include: Station Annunciator SCADA System SER Recorder Certain end-use devices, such as numerical relays, may additionally provide alarm indication for loss of synchronizing signal, as well as possib ...
... These alarms should be monitored in a manner consistent with established practice, which could include: Station Annunciator SCADA System SER Recorder Certain end-use devices, such as numerical relays, may additionally provide alarm indication for loss of synchronizing signal, as well as possib ...
Operators Manual
... This tab allows you to alter the operating characteristics of the AXE. Changes made on this pane only take effect after the “SET’ button is pressed. “Refresh” will read the current settings from the controller. After any changes have been “SET”, always click “REFRESH” to confirm the changes were acc ...
... This tab allows you to alter the operating characteristics of the AXE. Changes made on this pane only take effect after the “SET’ button is pressed. “Refresh” will read the current settings from the controller. After any changes have been “SET”, always click “REFRESH” to confirm the changes were acc ...
... plus one planned) transmission lines and the HAR 3 switchyard is connected to three transmission lines. For both HAR 2 and HAR 3, no single transmission line is designated as the preferred circuit. Each of the unit’s transmission lines has sufficient capacity and capability from the transmission net ...
ODEN AT - Progusa
... of the current unit: S, X and H. The S and X current units are identical except that the X unit has an additional 30/60 V output. The H unit is rated for even higher current. This makes it possible to configure an ODEN AT™ system in a suitable way. All parts are portable, and ODEN AT™ can be quickly ...
... of the current unit: S, X and H. The S and X current units are identical except that the X unit has an additional 30/60 V output. The H unit is rated for even higher current. This makes it possible to configure an ODEN AT™ system in a suitable way. All parts are portable, and ODEN AT™ can be quickly ...
D1213A-02SO Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
RSF010P05
... Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fi ...
... Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fi ...
MAX2058 700MHz to 1200MHz High-Linearity, SPI-Controlled DVGA with Integrated Loopback Mixer General Description
... θJC ....................................................................................10°C/W θJA ....................................................................................38°C/W Storage Temperature Range .............................-65°C to +150°C Lead Temperature (soldering, 10s) ..... ...
... θJC ....................................................................................10°C/W θJA ....................................................................................38°C/W Storage Temperature Range .............................-65°C to +150°C Lead Temperature (soldering, 10s) ..... ...
електроника electronics - Electronics Journal
... symposium. This is a part of very successful collaboration between the Faculty of Electrical Engineering in Banja Luka and the Faculty of Technical Sciences in Novi Sad (Yugoslavia) in several fields and particularly in organization of two related international conferences – International Conference ...
... symposium. This is a part of very successful collaboration between the Faculty of Electrical Engineering in Banja Luka and the Faculty of Technical Sciences in Novi Sad (Yugoslavia) in several fields and particularly in organization of two related international conferences – International Conference ...
Manufacturer Specifications – What do they Mean
... Ultimately, the MTE user must determine which specifications are relevant to their application. Therefore, a basic understanding of the fundamental operating principles of the MTE is an important requirement for proper interpretation of performance specifications. In some cases, first-hand experienc ...
... Ultimately, the MTE user must determine which specifications are relevant to their application. Therefore, a basic understanding of the fundamental operating principles of the MTE is an important requirement for proper interpretation of performance specifications. In some cases, first-hand experienc ...
2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System
... non-safety-related plant loads during normal and abnormal operations. EPSS divisions are independent and physically separated during normal bus alignments. An alternate feed is provided between EPSS divisions 1 and 2, and between divisions 3 and 4 to provide the normal and standby source of power to ...
... non-safety-related plant loads during normal and abnormal operations. EPSS divisions are independent and physically separated during normal bus alignments. An alternate feed is provided between EPSS divisions 1 and 2, and between divisions 3 and 4 to provide the normal and standby source of power to ...
MAX987/MAX988/MAX991/MAX992/MAX995/MAX996 High-Speed, Micropower, Low-Voltage, SOT23, Rail-to-Rail I/O Comparators ________________General Description
... The output stage’s unique design limits supply-current surges while switching, virtually eliminating the supply glitches typical of many other comparators. The MAX987/MAX991/MAX995 have a push-pull output stage that sinks as well as sources current. Large internal output drivers allow rail-to-rail o ...
... The output stage’s unique design limits supply-current surges while switching, virtually eliminating the supply glitches typical of many other comparators. The MAX987/MAX991/MAX995 have a push-pull output stage that sinks as well as sources current. Large internal output drivers allow rail-to-rail o ...