
Vibration measurement
... The proximity transducer system measures the motion of the shaft relative to the transducer tip. As the transducer is located close to the bearing (less than 6”) the proximity probe can be considered to measure the motion of the shaft relative to the bearing. This gives an indication of the amount o ...
... The proximity transducer system measures the motion of the shaft relative to the transducer tip. As the transducer is located close to the bearing (less than 6”) the proximity probe can be considered to measure the motion of the shaft relative to the bearing. This gives an indication of the amount o ...
Effects of Measurements and Pseudo
... other buses phase angles. When synchronized measurements are present, it is instead possible to measure the absolute phase angles with respect to the coordinated universal time (UTC), given by global positioning system (GPS), or other synchronization sources (see for instance [19], [20]). The pseudo ...
... other buses phase angles. When synchronized measurements are present, it is instead possible to measure the absolute phase angles with respect to the coordinated universal time (UTC), given by global positioning system (GPS), or other synchronization sources (see for instance [19], [20]). The pseudo ...
Accurate Fault Location Algorithm on Power Transmission Lines
... Rapid grow of power system grids during last years caused an increase in both the number of lines and their total length. Along with power energy consumption rise, a continuous and reliable energy supply is demanded. Transmission lines are essential parts of a power system for power energy delivery ...
... Rapid grow of power system grids during last years caused an increase in both the number of lines and their total length. Along with power energy consumption rise, a continuous and reliable energy supply is demanded. Transmission lines are essential parts of a power system for power energy delivery ...
High Voltage Ceramic Capacitors
... This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. ...
... This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. ...
Accurate Fault Location Algorithm on Power Transmission Lines
... Rapid grow of power system grids during last years caused an increase in both the number of lines and their total length. Along with power energy consumption rise, a continuous and reliable energy supply is demanded. Transmission lines are essential parts of a power system for power energy delivery ...
... Rapid grow of power system grids during last years caused an increase in both the number of lines and their total length. Along with power energy consumption rise, a continuous and reliable energy supply is demanded. Transmission lines are essential parts of a power system for power energy delivery ...
AZV331 Description Pin Assignments
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
PM1200 power meter - Schneider Electric
... Hazard Categories and Special Symbols Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential h ...
... Hazard Categories and Special Symbols Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential h ...
DXT696BK Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
High-Voltage Circuit Breakers
... The foundation of quality for Siemens high-voltage circuit breakers begins right in the development of a new product. Switching performance, high voltage stability and performance under normal mechanical loads (wind and short circuits) as well as seismic conditions are simulated and optimized in the ...
... The foundation of quality for Siemens high-voltage circuit breakers begins right in the development of a new product. Switching performance, high voltage stability and performance under normal mechanical loads (wind and short circuits) as well as seismic conditions are simulated and optimized in the ...
AD7273/AD7274 3 MSPS, 10-/12-Bit ADCs in 8
... successive approximation ADCs, respectively. The parts operate from a single 2.35 V to 3.6 V power supply and feature throughput rates of up to 3 MSPS. Each part contains a low noise, wide bandwidth track-and-hold amplifier that can handle input frequencies in excess of 55 MHz. The conversion proces ...
... successive approximation ADCs, respectively. The parts operate from a single 2.35 V to 3.6 V power supply and feature throughput rates of up to 3 MSPS. Each part contains a low noise, wide bandwidth track-and-hold amplifier that can handle input frequencies in excess of 55 MHz. The conversion proces ...
M1601_Intersection_Traffic_Light_PDA_Manual
... This Power Distribution Assembly (PDA) was designed as a “UPS ready” power supply for traffic cabinets. This power supply allows for easy connection of a UPS to the power supply and allows the UPS to be a detachable unit that may be added or removed from the panel at any time, without interruption o ...
... This Power Distribution Assembly (PDA) was designed as a “UPS ready” power supply for traffic cabinets. This power supply allows for easy connection of a UPS to the power supply and allows the UPS to be a detachable unit that may be added or removed from the panel at any time, without interruption o ...
Selecting Directional Elements for Impedance-Grounded
... According to an IEEE standard [5], an effectively grounded system complies with (X0/X1) ≤ 3 and (R0/X1) ≤ 1, where X0 and R0 are the zero-sequence reactance and resistance, and X1 is the positive-sequence reactance of the power system. In North America, effectively grounded distribution systems are ...
... According to an IEEE standard [5], an effectively grounded system complies with (X0/X1) ≤ 3 and (R0/X1) ≤ 1, where X0 and R0 are the zero-sequence reactance and resistance, and X1 is the positive-sequence reactance of the power system. In North America, effectively grounded distribution systems are ...
Power Factor in Electrical Energy Management
... From the above list, we can see that a low power factor can be a result of the design of the equipment, as in the case of welders, or it can be result from the operating conditions under which the equipment is used, as in lightly loaded induction motors which are probably the worst offenders. Equipm ...
... From the above list, we can see that a low power factor can be a result of the design of the equipment, as in the case of welders, or it can be result from the operating conditions under which the equipment is used, as in lightly loaded induction motors which are probably the worst offenders. Equipm ...
C653-C625 TG13G.indd
... extended cranking time to start the engine—system volts will measure lower than the regulator setpoint after the engine is restarted and system amps will measure higher. This is a normal condition for the charging system; the greater the battery discharge level, the lower the system volts and the hi ...
... extended cranking time to start the engine—system volts will measure lower than the regulator setpoint after the engine is restarted and system amps will measure higher. This is a normal condition for the charging system; the greater the battery discharge level, the lower the system volts and the hi ...
Low-Power Single Loop and Dual-Loop AGCs for Bionic Ears
... the DSP by making a software AGC unnecessary. However, a charge pump circuit must be used to allow operation at the low supply voltages that are typical in hearing aids. The pump can increase the power consumption by a factor of 2–3 depending on its efficiency, often limited by parasitics. In this p ...
... the DSP by making a software AGC unnecessary. However, a charge pump circuit must be used to allow operation at the low supply voltages that are typical in hearing aids. The pump can increase the power consumption by a factor of 2–3 depending on its efficiency, often limited by parasitics. In this p ...
replacing selenium rectifiers
... exceeding 500 V. To replace them with selenium would require a very long stack of plates, certainly a dozen or more in series. But this fact highlights the really dramatic advantage of silicon rectifiers. In many circuits, one 1N4007 can be used to replace each plate of a dual rectifier tube. This s ...
... exceeding 500 V. To replace them with selenium would require a very long stack of plates, certainly a dozen or more in series. But this fact highlights the really dramatic advantage of silicon rectifiers. In many circuits, one 1N4007 can be used to replace each plate of a dual rectifier tube. This s ...
Conditions for Setting the DTC
... The vehicle stability enhancement system (VSES) is activated by the electronic brake control module (EBCM) calculating the desired yaw rate and comparing it to the actual yaw rate input. The desired yaw rate is calculated from measured steering wheel position, vehicle speed, and lateral acceleration ...
... The vehicle stability enhancement system (VSES) is activated by the electronic brake control module (EBCM) calculating the desired yaw rate and comparing it to the actual yaw rate input. The desired yaw rate is calculated from measured steering wheel position, vehicle speed, and lateral acceleration ...