• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Tracing Network flows due to Sources/Sinks using Virtual flow Concept
Tracing Network flows due to Sources/Sinks using Virtual flow Concept

... methods are discussed in reference [8]. Postage stamp method practised in some markets even though simple to adopt, fails to give proper indication due to which large loads get the benefit over small loads. Pro rata method ignores the generation/load location in the network and remote generations/lo ...
ds26ls31cm
ds26ls31cm

... digital data transmission over balanced lines. The DS26LS31 meets all the requirements of EIA Standard RS-422 and Federal Standard 1020. It is designed to provide unipolar differential drive to twisted-pair or parallel-wire transmission lines. The circuit provides an enable and disable function comm ...
ELG4125: Symmetrical Faults
ELG4125: Symmetrical Faults

... period is called the sub-transient current and is denoted by I”. This current is caused by the damper windings of synchronous machines. The time constant of the sub-transient current is denoted by T” and it can be determined from the slope. This current may be 10 times the steady-state fault current ...
ELEC 120L Foundations of Electrical
ELEC 120L Foundations of Electrical

... A function generator is a type of test equipment that generates time-varying signals with specific kinds of waveforms, most frequently sinusoids, square waves, and triangular (or “sawtooth”) waves. The signal generated by a function generator is typically made available to the outside world via a co ...
New Products launched 2016
New Products launched 2016

AND8291/D >85% Efficient 12 to 5 VDC Buck Converter
AND8291/D >85% Efficient 12 to 5 VDC Buck Converter

... The selection of the timing capacitor CT (C4) and feedforward resistor R6 is discussed next. Assuming no circuit losses, the transfer function or gain of this application is 0.42 and is also 0.42. Referring to Table1, a 3:1 ratio for the external charging current to internal charging current would ...
understanding vector diagrams
understanding vector diagrams

SNP-HF3 Series
SNP-HF3 Series

International Journal of Energy and Power Engineering
International Journal of Energy and Power Engineering

... cannot be determined. In addition, gross-error in one of the input quantities can cause the load flow solution to be useless. In practice, other conveniently measured quantities such as real and reactive power flows are available, but they cannot be used in the load flow program. These limitations c ...
In-Vivo
In-Vivo

... within the circuit and must be accurately filtered out. • Voltage amplification • Offset voltage removal: The sensors bridge is not symmetric when no pressure is applied. This lack of symmetry results in an offset voltage that reduces the ...
Circuit Note CN-0130
Circuit Note CN-0130

... −22 V to +25 V, limited by the maximum allowable voltage of |AVDD − AVSS| ≤ 33 V. In addition, the current range that the AD5560 can deliver can be as high as ±1.2 A. Note that 1.2 A isn’t practical at the higher output voltages because of the power dissipation limitations of the package. The 1.2 A ...
1C.2.1—Voltage Level and Range
1C.2.1—Voltage Level and Range

Zelio Analog Interface Modules
Zelio Analog Interface Modules

BDTIC Modules for Photo-Voltaic String and Multi-String Inverters
BDTIC Modules for Photo-Voltaic String and Multi-String Inverters

... can be achieved. Fast and solder-less assembly is possible using the proven PressFIT technology. Reliability at the highest level was a clear focus during development. Solutions are available for single-phase and three-phase photo-voltaic inverters. ...
references - IEEE Taipei Section
references - IEEE Taipei Section

ELECTRICAL Engineering Interview Questions With
ELECTRICAL Engineering Interview Questions With

FJA4210 PNP Epitaxial Silicon Transistor F JA
FJA4210 PNP Epitaxial Silicon Transistor F JA

... SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: ...
2N4416 2N4416A SST4416 JFET
2N4416 2N4416A SST4416 JFET

FRYBABY2 Compact Burn-in Generator  Made in USA
FRYBABY2 Compact Burn-in Generator Made in USA

... In current mode, the cable is short circuited, and conductors are exercised via magnetic fields. Short-circuit the far end of the cable or form a loop by returning the cable to the other FryBaby2 output. Current mode is not applicable when using the FryBaby2 to burn in amplification. ...
Microelectromechanical Devices
Microelectromechanical Devices

... Applies when /2<<. 2) Force-commutated inverter Applies when <<3/2. ...
Signals and Systems
Signals and Systems

... each value of the signal is fixed and can be determined by a mathematical expression, rule, or table. Because of this the future values of the signal can be calculated from past values with complete confidence. Random signal has a lot of uncertainty about its behavior. The future values of a random ...
Five Level Flying-Capacitor Multilevel Converter Using Dynamic
Five Level Flying-Capacitor Multilevel Converter Using Dynamic

... are controller, voltage source inverter, energy source for DC link capacitor, filters and interfacing transformers. The DVR is basically a voltage source inverter which compensates the missing voltage by rapidly injecting set of three phase voltages into the lines via booster transformer. The voltag ...
Thevenin and Max Power
Thevenin and Max Power

... #1 Mistake with AC Max Power is not using the REAL value of resistance when calculating Pmax Transform ZTH into rectangular form to determine RTH ...
SoC_Embedded Processor2
SoC_Embedded Processor2

... • Pleakage: leakage power consumed by the device – Due to leakage currents from reversed biased PN junctions associated with source and drain of MOS transistors, as well as subthreshold conduction currents. – The leakage components proportional to device area and exponentially dependent on temperatu ...
cathode-mixing.pdf
cathode-mixing.pdf

... Signals coming in on the cathode will not be inverted so they are in phase with the plate output. Seems like it could be a way to mix out-of-phase signals plus produce gain at the same time. I doubt if this is new, there's probably a little something about it in RDH4 ;) Depends on where you get your ...
< 1 ... 815 816 817 818 819 820 821 822 823 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report