High Voltage Power Supplies
... Series 2290 Power Supplies and a Model 2290PM-200 Protection Module protect both user and instrumentation from hazardous voltages. An interlock circuit built into the power supplies can be used to ensure that the output voltage is disabled if a high voltage test fixture access door is open. In addit ...
... Series 2290 Power Supplies and a Model 2290PM-200 Protection Module protect both user and instrumentation from hazardous voltages. An interlock circuit built into the power supplies can be used to ensure that the output voltage is disabled if a high voltage test fixture access door is open. In addit ...
HSF-1UR - Kepco power supplies
... operating in a parallel configuration causes output current to be shared equally. (See Rack Adapter Manual for additional information on parallel configurations.). For current sharing to work properly the outputs of all paralleled units must be within 250 mV (max) of each other and each unit must be ...
... operating in a parallel configuration causes output current to be shared equally. (See Rack Adapter Manual for additional information on parallel configurations.). For current sharing to work properly the outputs of all paralleled units must be within 250 mV (max) of each other and each unit must be ...
Application Note No. 099
... Measurement Results oscillation at a temperature of 25 °C and a supply voltage of 3 V. Please note that the shift in frequency of oscillation is only a few kilohertz and this shift depends strongly on the performance of the SAW-resonator used in the application. ...
... Measurement Results oscillation at a temperature of 25 °C and a supply voltage of 3 V. Please note that the shift in frequency of oscillation is only a few kilohertz and this shift depends strongly on the performance of the SAW-resonator used in the application. ...
CS EU Operation and installation manual SOLIVIA CS EU G3
... MPP is achieved through the software. The central inverter easily changes its operating point again and again and compares the new output with that of the previous operating point. The software then decides whether the new operating point is better than the old one. This procedure is also known as t ...
... MPP is achieved through the software. The central inverter easily changes its operating point again and again and compares the new output with that of the previous operating point. The software then decides whether the new operating point is better than the old one. This procedure is also known as t ...
Example 1 - UniMAP Portal
... A 15-kVA 8000/230V distribution transformer has impedance referred to the primary of 80 + j300 Ω. The components of the excitation branch referred to the primary side are RC = 350kΩ and XM = 70kΩ. a) If the primary voltage is 7967 V and the load impedance is ZL = 3.0 + j1.5Ω, what is the secondary v ...
... A 15-kVA 8000/230V distribution transformer has impedance referred to the primary of 80 + j300 Ω. The components of the excitation branch referred to the primary side are RC = 350kΩ and XM = 70kΩ. a) If the primary voltage is 7967 V and the load impedance is ZL = 3.0 + j1.5Ω, what is the secondary v ...
S280-77-6
... External leads must be shielded and the shield must be grounded at both ends. Terminate the shield and each lead with a GE V150LA20A metal oxide varistor (MOV), or equivalent, at the remote end. Attach MOV’s between the leads and ground. Failure to properly shield and protect leads can result in equ ...
... External leads must be shielded and the shield must be grounded at both ends. Terminate the shield and each lead with a GE V150LA20A metal oxide varistor (MOV), or equivalent, at the remote end. Attach MOV’s between the leads and ground. Failure to properly shield and protect leads can result in equ ...
CRO notes(8th Unit)
... signal in various parts of the circuit. It, in effect, gives to ‘see’ what is happening inside the circuit itself. It is only by ‘seeing’ the signal waveform can correct errors, understand mistakes in the circuit design and thus make suitable adjustments. ...
... signal in various parts of the circuit. It, in effect, gives to ‘see’ what is happening inside the circuit itself. It is only by ‘seeing’ the signal waveform can correct errors, understand mistakes in the circuit design and thus make suitable adjustments. ...
Lab- Parallel Circuits
... Method – Part A – Series circuit 1. Connect a series circuit. Start at the negative terminal and add on the components in the following order: power source set to 10 V, ammeter, open switch, bulb, resistor. 2. Turn on the source and close the switch. Record the current (IT) in observation Table 1. 3 ...
... Method – Part A – Series circuit 1. Connect a series circuit. Start at the negative terminal and add on the components in the following order: power source set to 10 V, ammeter, open switch, bulb, resistor. 2. Turn on the source and close the switch. Record the current (IT) in observation Table 1. 3 ...
Final Report – Team 1613
... and have an effective charger. But then resistance across the load, now becomes a problem. As shown above, the resistance values are different between configurations. The easiest solution to this is just sticking with one configuration for our charger. Another, more complex option is to put two resi ...
... and have an effective charger. But then resistance across the load, now becomes a problem. As shown above, the resistance values are different between configurations. The easiest solution to this is just sticking with one configuration for our charger. Another, more complex option is to put two resi ...
AP8803 Description Features Pin Assignments Typical Applications
... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. ...
... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. ...
Safety precautions and elementary First aid
... Drilling practice, fitting exercises on various shapes, of measuring and marking. Description of files, hammers , chisels, Tapping and Chipping hacksaw frames , blades -their specifications and uses. Different Practice on cutting, plaining and making different joints Metals and alloys- their charact ...
... Drilling practice, fitting exercises on various shapes, of measuring and marking. Description of files, hammers , chisels, Tapping and Chipping hacksaw frames , blades -their specifications and uses. Different Practice on cutting, plaining and making different joints Metals and alloys- their charact ...
ACS754xCB-050
... Copyright ©2004-2008, Allegro MicroSystems, Inc. The products described herein are manufactured under one or more of the following U.S. patents: 5,045,920; 5,264,783; 5,442,283; 5,389,889; 5,581,179; 5,517,112; 5,619,137; 5,621,319; 5,650,719; 5,686,894; 5,694,038; 5,729,130; 5,917,320; and other pa ...
... Copyright ©2004-2008, Allegro MicroSystems, Inc. The products described herein are manufactured under one or more of the following U.S. patents: 5,045,920; 5,264,783; 5,442,283; 5,389,889; 5,581,179; 5,517,112; 5,619,137; 5,621,319; 5,650,719; 5,686,894; 5,694,038; 5,729,130; 5,917,320; and other pa ...
BDTIC
... The Low Power Hall IC Switch comprises a Hall probe, bias generator, compensation circuits, oscillator, output latch and an n-channel open drain output transistor. The bias generator provides currents for the Hall probe and the active circuits. Compensation circuits stabilize the temperature behavio ...
... The Low Power Hall IC Switch comprises a Hall probe, bias generator, compensation circuits, oscillator, output latch and an n-channel open drain output transistor. The bias generator provides currents for the Hall probe and the active circuits. Compensation circuits stabilize the temperature behavio ...
LIGHTNING THEORY – Explanations
... Much has been written about the protection of equipment connected to Smart Grid AC power [see for example www.NEMASURGE.com], but little has been said about protection of Smart Grid communications. Protection of communication links is important, because Smart Grid operation depends on two-way commun ...
... Much has been written about the protection of equipment connected to Smart Grid AC power [see for example www.NEMASURGE.com], but little has been said about protection of Smart Grid communications. Protection of communication links is important, because Smart Grid operation depends on two-way commun ...
AN-1958 LMP860X SOIC Eval Board User`s Guide
... stages, a preamplifier with a gain of 10x and an output stage buffer amplifier with a gain of 2x, 5x, 10x. The connection between the two stages of the signal path is brought out on two pins to enable the possibility to create an additional filter network around the output buffer amplifier. These pi ...
... stages, a preamplifier with a gain of 10x and an output stage buffer amplifier with a gain of 2x, 5x, 10x. The connection between the two stages of the signal path is brought out on two pins to enable the possibility to create an additional filter network around the output buffer amplifier. These pi ...
Digilent NXVGA Reference Manual
... and those rays are fed by the current that flows into the cathodes. These particle rays are initially accelerated towards the grid, but they soon fall under the influence of the much larger electrostatic force that results from the entire phosphor-coated display surface of the CRT being charged to 2 ...
... and those rays are fed by the current that flows into the cathodes. These particle rays are initially accelerated towards the grid, but they soon fall under the influence of the much larger electrostatic force that results from the entire phosphor-coated display surface of the CRT being charged to 2 ...
LM193JAN Low Power Low Offset Voltage Dual
... which the device is functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not ...
... which the device is functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not ...